Stability of the LIPAc beam dump to vibrations induced bythe cooling flow
The beam dump of the LIPAc consists of a long and thin copper cone where the ions are stopped, cooled by water flowing along its outer surface. The high water velocity (between 4 and 8 m/s) and the turbulent regimes involved may compromise the mechanical stability of the slender beam dump structure...
| Autores: | , , , , , , , , , |
|---|---|
| Formato: | artículo |
| Fecha de publicación: | 2014 |
| País: | España |
| Recursos: | Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT) |
| Repositorio: | Docu-menta. Repositorio Institucional del CIEMAT |
| Idioma: | inglés |
| OAI Identifier: | oai:dnet:documenta___::ed849d27bbc33bc73d6b296e60a9c26a |
| Acesso em linha: | https://hdl.handle.net/20.500.14855/2166 |
| Access Level: | acceso abierto |
| id |
ES_bcb97d9f4a5b00f72d4ef4015202f7b5 |
|---|---|
| oai_identifier_str |
oai:dnet:documenta___::ed849d27bbc33bc73d6b296e60a9c26a |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Stability of the LIPAc beam dump to vibrations induced bythe cooling flowOlmos, P.Rapisarda, D.Rueda, F.Arranz, F.Barrera, G.Brañas, B.García, A.Medrano, M.Olalde, J.Maqueda, L.The beam dump of the LIPAc consists of a long and thin copper cone where the ions are stopped, cooled by water flowing along its outer surface. The high water velocity (between 4 and 8 m/s) and the turbulent regimes involved may compromise the mechanical stability of the slender beam dump structure and cause damages due to flow induced vibrations. Since the system is too complex to be studied theoretically, some tests have been carried out to evaluate its behavior in normal operating conditions. These tests, performed on a model built at 1:1 scale and replicating exactly the final version, have been focused on finding experimentally the main vibration modes and the responses to the different working flowrates. This modal analysis, together with the results of the measurements of the vibration characteristics obtained at several positions of the cone, is presented here. With amplitudes not greater than 500 mg rms in any case, the structure has proved its practical immunity to flow induced vibrations, thus validating its design and construction methodology.Elsevier. Fusion Engineering and Design20242024-01-2220142014-10-0120142014-10-01journal articlehttp://purl.org/coar/resource_type/c_6501info:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/20.500.14855/2166reponame:Docu-menta. Repositorio Institucional del CIEMATinstname:Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2info:eu-repo/semantics/openAccessoai:dnet:documenta___::ed849d27bbc33bc73d6b296e60a9c26a2026-06-18T12:40:47Z |
| dc.title.none.fl_str_mv |
Stability of the LIPAc beam dump to vibrations induced bythe cooling flow |
| title |
Stability of the LIPAc beam dump to vibrations induced bythe cooling flow |
| spellingShingle |
Stability of the LIPAc beam dump to vibrations induced bythe cooling flow Olmos, P. |
| title_short |
Stability of the LIPAc beam dump to vibrations induced bythe cooling flow |
| title_full |
Stability of the LIPAc beam dump to vibrations induced bythe cooling flow |
| title_fullStr |
Stability of the LIPAc beam dump to vibrations induced bythe cooling flow |
| title_full_unstemmed |
Stability of the LIPAc beam dump to vibrations induced bythe cooling flow |
| title_sort |
Stability of the LIPAc beam dump to vibrations induced bythe cooling flow |
| dc.creator.none.fl_str_mv |
Olmos, P. Rapisarda, D. Rueda, F. Arranz, F. Barrera, G. Brañas, B. García, A. Medrano, M. Olalde, J. Maqueda, L. |
| author |
Olmos, P. |
| author_facet |
Olmos, P. Rapisarda, D. Rueda, F. Arranz, F. Barrera, G. Brañas, B. García, A. Medrano, M. Olalde, J. Maqueda, L. |
| author_role |
author |
| author2 |
Rapisarda, D. Rueda, F. Arranz, F. Barrera, G. Brañas, B. García, A. Medrano, M. Olalde, J. Maqueda, L. |
| author2_role |
author author author author author author author author author |
| dc.contributor.none.fl_str_mv |
|
| description |
The beam dump of the LIPAc consists of a long and thin copper cone where the ions are stopped, cooled by water flowing along its outer surface. The high water velocity (between 4 and 8 m/s) and the turbulent regimes involved may compromise the mechanical stability of the slender beam dump structure and cause damages due to flow induced vibrations. Since the system is too complex to be studied theoretically, some tests have been carried out to evaluate its behavior in normal operating conditions. These tests, performed on a model built at 1:1 scale and replicating exactly the final version, have been focused on finding experimentally the main vibration modes and the responses to the different working flowrates. This modal analysis, together with the results of the measurements of the vibration characteristics obtained at several positions of the cone, is presented here. With amplitudes not greater than 500 mg rms in any case, the structure has proved its practical immunity to flow induced vibrations, thus validating its design and construction methodology. |
| publishDate |
2014 |
| dc.date.none.fl_str_mv |
2014 2014-10-01 2014 2014-10-01 2024 2024-01-22 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/20.500.14855/2166 |
| url |
https://hdl.handle.net/20.500.14855/2166 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Elsevier. Fusion Engineering and Design |
| publisher.none.fl_str_mv |
Elsevier. Fusion Engineering and Design |
| dc.source.none.fl_str_mv |
reponame:Docu-menta. Repositorio Institucional del CIEMAT instname:Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT) |
| instname_str |
Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT) |
| reponame_str |
Docu-menta. Repositorio Institucional del CIEMAT |
| collection |
Docu-menta. Repositorio Institucional del CIEMAT |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869418138697728000 |
| score |
15.812429 |