Field Oriented Control of Multiphase Drives with Passive Fault-Tolerance
Multiphase machines provide continuous operation of the drive with no additional hardware in the event of one or more open-phase faults. This faulttolerant capability is highly appreciated by industry for security and economic reasons. However, the steadystate post-fault operation has only been feas...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión aceptada para publicación |
| Fecha de publicación: | 2020 |
| País: | España |
| Institución: | Universidad de Sevilla (US) |
| Repositorio: | idUS. Depósito de Investigación de la Universidad de Sevilla |
| OAI Identifier: | oai:idus.us.es:11441/151487 |
| Acceso en línea: | https://hdl.handle.net/11441/151487 https://doi.org/10.1109/TIE.2019.2944056 |
| Access Level: | acceso abierto |
| Palabra clave: | Fault tolerance Field-oriented control Induction motors Multiphase drives |
| id |
ES_bc9c879f2cac27f847d91f7eee14ee9d |
|---|---|
| oai_identifier_str |
oai:idus.us.es:11441/151487 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Field Oriented Control of Multiphase Drives with Passive Fault-ToleranceGonzález Prieto, IgnacioDurán, Mario J.García Entrambasaguas, PaulaBermúdez Guzmán, MarioFault toleranceField-oriented controlInduction motorsMultiphase drivesMultiphase machines provide continuous operation of the drive with no additional hardware in the event of one or more open-phase faults. This faulttolerant capability is highly appreciated by industry for security and economic reasons. However, the steadystate post-fault operation has only been feasible in previous works after the fault localization and control reconfiguration. Even though this is done at the software stage, the obligation to identify the faulty phases and store the modifications for every fault scenario adds further complexity. This work reveals that this software reconfiguration can be avoided if the field-oriented control (FOC) strategy is designed to satisfactorily handle pre- and post-fault situations. Experimental results confirm the capability to obtain suitable postfault operation without fault localization and control reconfiguration, thus achieving a passive/natural fault tolerance.Ministerio de Ciencia, Innovación y Universidades RTI2018-096151-B-I00Institute of Electrical and Electronics EngineersIngeniería EléctricaTEP196: Sistemas de Energía EléctricaMinisterio de Ciencia, Innovación y Universidades (MICINN). España2020info:eu-repo/semantics/articleinfo:eu-repo/semantics/acceptedVersionapplication/pdfapplication/pdfhttps://hdl.handle.net/11441/151487https://doi.org/10.1109/TIE.2019.2944056reponame:idUS. Depósito de Investigación de la Universidad de Sevillainstname:Universidad de Sevilla (US)InglésIEEE Transactions on Industrial Electronics, 67 (9), 7228-7238.RTI2018-096151-B-I00https://ieeexplore.ieee.org/document/8859633info:eu-repo/semantics/openAccessoai:idus.us.es:11441/1514872026-06-17T12:51:07Z |
| dc.title.none.fl_str_mv |
Field Oriented Control of Multiphase Drives with Passive Fault-Tolerance |
| title |
Field Oriented Control of Multiphase Drives with Passive Fault-Tolerance |
| spellingShingle |
Field Oriented Control of Multiphase Drives with Passive Fault-Tolerance González Prieto, Ignacio Fault tolerance Field-oriented control Induction motors Multiphase drives |
| title_short |
Field Oriented Control of Multiphase Drives with Passive Fault-Tolerance |
| title_full |
Field Oriented Control of Multiphase Drives with Passive Fault-Tolerance |
| title_fullStr |
Field Oriented Control of Multiphase Drives with Passive Fault-Tolerance |
| title_full_unstemmed |
Field Oriented Control of Multiphase Drives with Passive Fault-Tolerance |
| title_sort |
Field Oriented Control of Multiphase Drives with Passive Fault-Tolerance |
| dc.creator.none.fl_str_mv |
González Prieto, Ignacio Durán, Mario J. García Entrambasaguas, Paula Bermúdez Guzmán, Mario |
| author |
González Prieto, Ignacio |
| author_facet |
González Prieto, Ignacio Durán, Mario J. García Entrambasaguas, Paula Bermúdez Guzmán, Mario |
| author_role |
author |
| author2 |
Durán, Mario J. García Entrambasaguas, Paula Bermúdez Guzmán, Mario |
| author2_role |
author author author |
| dc.contributor.none.fl_str_mv |
Ingeniería Eléctrica TEP196: Sistemas de Energía Eléctrica Ministerio de Ciencia, Innovación y Universidades (MICINN). España |
| dc.subject.none.fl_str_mv |
Fault tolerance Field-oriented control Induction motors Multiphase drives |
| topic |
Fault tolerance Field-oriented control Induction motors Multiphase drives |
| description |
Multiphase machines provide continuous operation of the drive with no additional hardware in the event of one or more open-phase faults. This faulttolerant capability is highly appreciated by industry for security and economic reasons. However, the steadystate post-fault operation has only been feasible in previous works after the fault localization and control reconfiguration. Even though this is done at the software stage, the obligation to identify the faulty phases and store the modifications for every fault scenario adds further complexity. This work reveals that this software reconfiguration can be avoided if the field-oriented control (FOC) strategy is designed to satisfactorily handle pre- and post-fault situations. Experimental results confirm the capability to obtain suitable postfault operation without fault localization and control reconfiguration, thus achieving a passive/natural fault tolerance. |
| publishDate |
2020 |
| dc.date.none.fl_str_mv |
2020 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/acceptedVersion |
| format |
article |
| status_str |
acceptedVersion |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/11441/151487 https://doi.org/10.1109/TIE.2019.2944056 |
| url |
https://hdl.handle.net/11441/151487 https://doi.org/10.1109/TIE.2019.2944056 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
IEEE Transactions on Industrial Electronics, 67 (9), 7228-7238. RTI2018-096151-B-I00 https://ieeexplore.ieee.org/document/8859633 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf application/pdf |
| dc.publisher.none.fl_str_mv |
Institute of Electrical and Electronics Engineers |
| publisher.none.fl_str_mv |
Institute of Electrical and Electronics Engineers |
| dc.source.none.fl_str_mv |
reponame:idUS. Depósito de Investigación de la Universidad de Sevilla instname:Universidad de Sevilla (US) |
| instname_str |
Universidad de Sevilla (US) |
| reponame_str |
idUS. Depósito de Investigación de la Universidad de Sevilla |
| collection |
idUS. Depósito de Investigación de la Universidad de Sevilla |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869418128823287808 |
| score |
15,300724 |