Intracardiac Echocardiography to Guide Watchman FLX Implantation: The ICE LAA Study

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly used to guide left atrial appendage closure (LAAC). OBJECTIVES: The aim of this study was to investigate the efficacy and safety of ICE-guided LAAC with the Watchman FLX device. METHODS: The ICE LAA (I Can See Left Atrial Appendage) stu...

ver descrição completa

Detalhes bibliográficos
Autores: Nielsen-Kudsk J.E., Berti S., Caprioglio F., Ronco F., Arzamendi D., Betts T., Tondo C., Christen T., Allocco D.J.
Formato: artículo
Estado:Versión publicada
Fecha de publicación:2023
País:España
Recursos:Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau)
Repositorio:r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
OAI Identifier:oai:iibsantpau.fundanetsuite.com:p16834
Acesso em linha:https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=16834
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85150395689&doi=10.1016%2fj.jcin.2022.10.024&partnerID=40&md5=62732d5469ea29ab8de768bb80155852
Access Level:acceso abierto
Palavra-chave:ICE
atrial fibrillation
intracardiac echocardiography
left atrial appendage
left atrial appendage closure
stroke prevention
Descrição
Resumo:BACKGROUND: Intracardiac echocardiography (ICE) is increasingly used to guide left atrial appendage closure (LAAC). OBJECTIVES: The aim of this study was to investigate the efficacy and safety of ICE-guided LAAC with the Watchman FLX device. METHODS: The ICE LAA (I Can See Left Atrial Appendage) study was a prospective, multicenter study with independent adjudication of echocardiographic data by a core laboratory and clinical events by a clinical events committee. Patients with atrial fibrillation with CHA(2)DS(2)-VASc scores =2 and clinical indications for LAAC were eligible. Preplanning with either cardiac computed tomography or transesophageal echocardiography (TEE) within 7 days prior to LAAC was mandatory. Intraprocedural ICE was carried out from the left atrium. The primary outcome was the rate of significant peridevice leaks (>5 mm) at 45-day TEE. RESULTS: A total of 100 patients were enrolled. The mean age was 76 ± 8 years, the mean CHA(2)DS(2)-VASc score was 4.0 ± 1.5, and the mean HAS-BLED score was 2.5 ± 0.9. The incidence of the primary outcome of significant peridevice leak (>5 mm) was 0%; all patients evaluated by TEE at 45 days had effective LAAC. All patients received Watchman FLX devices, and technical success was 100%. The number of devices per case was 1.0 ± 0.1. ICE successfully guided the assessment of device release criteria, including device compression (19.2% ± 7.1%; recommended range: 10%-30%). No subject required conversion to TEE. Procedural complications were 4 access-site bleeds. There was no stroke, transient ischemic attack, systemic embolization, pericardial effusion, device embolization, or device-related thrombus during the procedure or 45-day follow-up. CONCLUSIONS: ICE can be used to successfully guide LAAC with the Watchman FLX, with excellent procedural success, a high rate of effective LAAC, and minimal periprocedural complications. (I Can See Left Atrial Appendage [ICELAA] Clinical Study; NCT04196335).