First eurados intercomparison exercise of eye lens dosemeters for medical applications

In the context of the decrease in the eye lens dose limit for occupational exposure to 20 mSv per year stated by the recent revision of the European Basic Safety Standards Directive 2013/59/EURATOM, the European Radiation Dosimetry Group (EURADOS) has organised in 2014, for the first time, an interc...

Descripción completa

Detalles Bibliográficos
Autores: Clairand, Isabelle, Ginjaume Egido, Mercè|||0000-0002-6767-2624, Vanhavere, F., Carinou, Eleftheria, Daures, J., Denoziere, M., Silva, E. H., Roig Costa, Maria|||0000-0002-5066-1670, Principi, Sara, Van Rycheghem, L.
Tipo de recurso: artículo
Fecha de publicación:2016
País:España
Institución:Universitat Politècnica de Catalunya (UPC)
Repositorio:UPCommons. Portal del coneixement obert de la UPC
Idioma:inglés
OAI Identifier:oai:upcommons.upc.edu:2117/128799
Acceso en línea:https://hdl.handle.net/2117/128799
https://dx.doi.org/10.1093/rpd/ncv368
Access Level:acceso abierto
Palabra clave:Radiation dosimetry
Ophthalmic lenses
Radiació--Dosimetria
Lents oftàlmiques
Àrees temàtiques de la UPC::Física
Àrees temàtiques de la UPC::Ciències de la visió
Àrees temàtiques de la UPC::Ciències de la visió::Òptica física
Àrees temàtiques de la UPC::Física::Electromagnetisme
Descripción
Sumario:In the context of the decrease in the eye lens dose limit for occupational exposure to 20 mSv per year stated by the recent revision of the European Basic Safety Standards Directive 2013/59/EURATOM, the European Radiation Dosimetry Group (EURADOS) has organised in 2014, for the first time, an intercomparison exercise for eye lens dosemeters. The main objective was to assess the capabilities of the passive eye lens dosemeters currently in use in Europe for occupational monitoring in medical fields. A total of 20 European individual monitoring services from 15 different countries have participated. The dosemeters provided by the participants were all composed of thermoluminescent detectors, of various types and designs. The irradiations were carried out with several photon fields chosen to cover the energy and angle ranges encountered in medical workplace. Participants were asked to report the doses in terms of Hp(3) using their routine protocol. The results provided by each participant were compared with the reference delivered doses. All the results were anonymously analysed. Results are globally satisfactory since, among the 20 participants, 17 were able to provide 90 % of their response in accordance with the ISO 14146 standard requirements.