Application of a BEPU-based code assessment to the ATLAS upper head SB-LOCA test

The prevailing state of knowledge of two-phase flow in complex systems, as in the nuclear field, usually leads a certain degree of ad hoc calibration of computational models and the consequent inevitable subjectivity in analyses and assessments. The UPC-ANT Uncertainty Analysis methodology for code...

ver descrição completa

Detalhes bibliográficos
Autores: Al Awad, Abdulrahman|||0000-0002-5502-0207, Freixa Terradas, Jordi|||0000-0002-8173-3921, Pérez-Ferragut, Marina
Tipo de documento: artigo
Data de publicação:2021
País:España
Recursos:Universitat Politècnica de Catalunya (UPC)
Repositório:UPCommons. Portal del coneixement obert de la UPC
Idioma:inglês
OAI Identifier:oai:upcommons.upc.edu:2117/352910
Acesso em linha:https://hdl.handle.net/2117/352910
https://dx.doi.org/10.1016/j.anucene.2021.108581
Access Level:Acceso aberto
Palavra-chave:Nuclear power plants -- Safety measures
Nuclear energy -- Environmental aspects
System code
Code assessment
SB-LOCA
Integral test facility
ATLAS facility
Energia nuclear -- Aspectes ambientals
Centrals nuclears -- Mesures de seguretat
Àrees temàtiques de la UPC::Física
Descrição
Resumo:The prevailing state of knowledge of two-phase flow in complex systems, as in the nuclear field, usually leads a certain degree of ad hoc calibration of computational models and the consequent inevitable subjectivity in analyses and assessments. The UPC-ANT Uncertainty Analysis methodology for code assessment attempts to maintain scientifically desired features of models and analyses, by crediting BEPU analysis and centering the assessment criteria on T-H phenomenology rather than on safety criteria, as it is the usual practice. An SB-LOCA in the upper head is utilized as a case study, and global, chronological, FOMs and phenomenological analyses are carried out and illustrated briefly. Overall, it was concluded that the developed RELAP5 model reproduces all the relevant T-H phenomena to the investigated scenario, either partially or totally, and the BEPU methodology is generally adequate to perturb the underlying T-H phenomena.