Work Ability Index: Psychometric Testing in Aeronautical Industry Workers.

BACKGROUND: The Work Ability Index (WAI) is an instrument that measures work ability. The wide dispersion of the WAI internationally has led to its adaptation for use in different countries. This study aimed to evaluate the psychometric properties of the Spanish version of the WAI. METHODS: A method...

Descripción completa

Detalles Bibliográficos
Autores: González-Domínguez ME, Fernández-García E, Paloma-Castro O, González-López RM, Rivas Pérez MP, López-Molina L, García-Jiménez J, Romero-Sánchez JM
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2024
País:España
Institución:Fundación para el Fomento de la Investigación Sanitaria y Biomédica de la Comunitat Valenciana (FISABIO)
Repositorio:r-FISABIO. Repositorio Institucional de Producción Científica
OAI Identifier:oai:fisabio.fundanetsuite.com:p18095
Acceso en línea:https://fisabio.portalinvestigacion.com/publicaciones/18095
Access Level:acceso abierto
Palabra clave:Industry
Psychometrics
Reliability and validity
Spain
Work ability
id ES_b8eeedfc56e49b51beaaea1db196befc
oai_identifier_str oai:fisabio.fundanetsuite.com:p18095
network_acronym_str ES
network_name_str España
repository_id_str
spelling Work Ability Index: Psychometric Testing in Aeronautical Industry Workers.González-Domínguez MEFernández-García EPaloma-Castro OGonzález-López RMRivas Pérez MPLópez-Molina LGarcía-Jiménez JRomero-Sánchez JMIndustryPsychometricsReliability and validitySpainWork abilityBACKGROUND: The Work Ability Index (WAI) is an instrument that measures work ability. The wide dispersion of the WAI internationally has led to its adaptation for use in different countries. This study aimed to evaluate the psychometric properties of the Spanish version of the WAI. METHODS: A methodological design was used over an opportunistic sample of 233 workers in the aeronautical industry in Spain. Reliability was evaluated through internal consistency. Factorial validity, known groups, and convergent validity were tested. RESULTS: The Cronbach's alpha and item-total correlation indicated an adequate internal consistency. The confirmatory factor analysis, performed to evaluate the factorial validity, found adequate fit indices for a two-factor solution with a high correlation between the factors. Factor 1, "Subjectively estimated work ability and resources", was composed of 3 subscales and factor 2, "Ill-health-related", of 2 subscales. Subscales 4 and 6 had loading in both factors. Workers under 45 years of age obtained higher significant scores than older ones. Convergent validity was also evidenced since WAI was highly correlated with self-assessment of health status. CONCLUSIONS: The Spanish version of the WAI has shown evidence of reliability and validity in this study, supporting its use in individual and collective health surveillance by occupational health professionals. The factorial solution that was found has previously been reported in another international context. However, further research is needed to resolve the discrepancies detected in the role of some subscales between other national and international studies.ELSEVIER2024info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttps://fisabio.portalinvestigacion.com/publicaciones/18095Safety and Health at WorkISSN: 20937911ISSNe: 20937997reponame:r-FISABIO. Repositorio Institucional de Producción Científicainstname:Fundación para el Fomento de la Investigación Sanitaria y Biomédica de la Comunitat Valenciana (FISABIO)Inglésinfo:eu-repo/semantics/openAccessoai:fisabio.fundanetsuite.com:p180952026-06-11T12:45:17Z
dc.title.none.fl_str_mv Work Ability Index: Psychometric Testing in Aeronautical Industry Workers.
title Work Ability Index: Psychometric Testing in Aeronautical Industry Workers.
spellingShingle Work Ability Index: Psychometric Testing in Aeronautical Industry Workers.
González-Domínguez ME
Industry
Psychometrics
Reliability and validity
Spain
Work ability
title_short Work Ability Index: Psychometric Testing in Aeronautical Industry Workers.
title_full Work Ability Index: Psychometric Testing in Aeronautical Industry Workers.
title_fullStr Work Ability Index: Psychometric Testing in Aeronautical Industry Workers.
title_full_unstemmed Work Ability Index: Psychometric Testing in Aeronautical Industry Workers.
title_sort Work Ability Index: Psychometric Testing in Aeronautical Industry Workers.
dc.creator.none.fl_str_mv González-Domínguez ME
Fernández-García E
Paloma-Castro O
González-López RM
Rivas Pérez MP
López-Molina L
García-Jiménez J
Romero-Sánchez JM
author González-Domínguez ME
author_facet González-Domínguez ME
Fernández-García E
Paloma-Castro O
González-López RM
Rivas Pérez MP
López-Molina L
García-Jiménez J
Romero-Sánchez JM
author_role author
author2 Fernández-García E
Paloma-Castro O
González-López RM
Rivas Pérez MP
López-Molina L
García-Jiménez J
Romero-Sánchez JM
author2_role author
author
author
author
author
author
author
dc.subject.none.fl_str_mv Industry
Psychometrics
Reliability and validity
Spain
Work ability
topic Industry
Psychometrics
Reliability and validity
Spain
Work ability
description BACKGROUND: The Work Ability Index (WAI) is an instrument that measures work ability. The wide dispersion of the WAI internationally has led to its adaptation for use in different countries. This study aimed to evaluate the psychometric properties of the Spanish version of the WAI. METHODS: A methodological design was used over an opportunistic sample of 233 workers in the aeronautical industry in Spain. Reliability was evaluated through internal consistency. Factorial validity, known groups, and convergent validity were tested. RESULTS: The Cronbach's alpha and item-total correlation indicated an adequate internal consistency. The confirmatory factor analysis, performed to evaluate the factorial validity, found adequate fit indices for a two-factor solution with a high correlation between the factors. Factor 1, "Subjectively estimated work ability and resources", was composed of 3 subscales and factor 2, "Ill-health-related", of 2 subscales. Subscales 4 and 6 had loading in both factors. Workers under 45 years of age obtained higher significant scores than older ones. Convergent validity was also evidenced since WAI was highly correlated with self-assessment of health status. CONCLUSIONS: The Spanish version of the WAI has shown evidence of reliability and validity in this study, supporting its use in individual and collective health surveillance by occupational health professionals. The factorial solution that was found has previously been reported in another international context. However, further research is needed to resolve the discrepancies detected in the role of some subscales between other national and international studies.
publishDate 2024
dc.date.none.fl_str_mv 2024
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://fisabio.portalinvestigacion.com/publicaciones/18095
url https://fisabio.portalinvestigacion.com/publicaciones/18095
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv ELSEVIER
publisher.none.fl_str_mv ELSEVIER
dc.source.none.fl_str_mv Safety and Health at Work
ISSN: 20937911
ISSNe: 20937997
reponame:r-FISABIO. Repositorio Institucional de Producción Científica
instname:Fundación para el Fomento de la Investigación Sanitaria y Biomédica de la Comunitat Valenciana (FISABIO)
instname_str Fundación para el Fomento de la Investigación Sanitaria y Biomédica de la Comunitat Valenciana (FISABIO)
reponame_str r-FISABIO. Repositorio Institucional de Producción Científica
collection r-FISABIO. Repositorio Institucional de Producción Científica
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869417690724040704
score 15,811543