Parametric study of the operational and economic feasibility of Stirling micro-cogeneration devices in Spain
This paper analyses the operational and economic viability of Stirling engine-run micro-cogeneration units in single-family houses in Spain. Thermal demands for the reference dwelling, sited in three different and representative climatic zones, are obtained based on heating and domestic hot water re...
| Autores: | , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2013 |
| País: | España |
| Institución: | Universidad del País Vasco |
| Repositorio: | Addi. Archivo Digital para la Docencia y la Investigación |
| OAI Identifier: | oai:addi.ehu.eus:10810/64656 |
| Acceso en línea: | http://hdl.handle.net/10810/64656 |
| Access Level: | acceso abierto |
| Palabra clave: | stirling micro-CHP dynamic simulation viability single-family dwelling Spain |
| id |
ES_b7befe2494882c87e70cdbdf018cdb7e |
|---|---|
| oai_identifier_str |
oai:addi.ehu.eus:10810/64656 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Parametric study of the operational and economic feasibility of Stirling micro-cogeneration devices in SpainGonzález Pino, IkerCampos Celador, ÁlvaroPérez Iribarren, EstibalizTerés Zubiaga, JonSala Lizarraga, José María Pedrostirling micro-CHPdynamic simulationviabilitysingle-family dwellingSpainThis paper analyses the operational and economic viability of Stirling engine-run micro-cogeneration units in single-family houses in Spain. Thermal demands for the reference dwelling, sited in three different and representative climatic zones, are obtained based on heating and domestic hot water requirements. By carrying out dynamic simulations of both the conventional and cogeneration installations, their performances are obtained and compared. Additionally, based on the results obtained in the simulations, economic viability of the Stirling engine-based micro-CHP is evaluated, taking into account Spanish regulation and economic framework, particularly fuel and electricity prices. Finally, a sensibility study is carried out in order to evaluate how economic results of these plants are affected by both variations in fuel and electricity prices as well as in initial investment costs. It is concluded that there is no opportunity for these devices to be feasible in new and retrofitted single-family dwellings sited in any climatic zone of Spain but in the coldest ones, where the micro-CHP plants could become viable if the Stirling engine investment cost decreases.Iker González-Pino and Jon Terés-Zubiaga acknowledge the financial support of the Basque Government, through the Department of Education, Universities and Research’s Personnel Research Training Program. Many thanks also to the Laboratory for the Quality Control in Buildings (LCCE) of the Basque Government.Elsevier202420242013info:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10810/64656reponame:Addi. Archivo Digital para la Docencia y la Investigacióninstname:Universidad del País VascoIngléshttps://doi.org/10.1016/j.applthermaleng.2013.12.020info:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/4.0/© 2013 Elsevier under CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)oai:addi.ehu.eus:10810/646562026-06-18T09:23:17Z |
| dc.title.none.fl_str_mv |
Parametric study of the operational and economic feasibility of Stirling micro-cogeneration devices in Spain |
| title |
Parametric study of the operational and economic feasibility of Stirling micro-cogeneration devices in Spain |
| spellingShingle |
Parametric study of the operational and economic feasibility of Stirling micro-cogeneration devices in Spain González Pino, Iker stirling micro-CHP dynamic simulation viability single-family dwelling Spain |
| title_short |
Parametric study of the operational and economic feasibility of Stirling micro-cogeneration devices in Spain |
| title_full |
Parametric study of the operational and economic feasibility of Stirling micro-cogeneration devices in Spain |
| title_fullStr |
Parametric study of the operational and economic feasibility of Stirling micro-cogeneration devices in Spain |
| title_full_unstemmed |
Parametric study of the operational and economic feasibility of Stirling micro-cogeneration devices in Spain |
| title_sort |
Parametric study of the operational and economic feasibility of Stirling micro-cogeneration devices in Spain |
| dc.creator.none.fl_str_mv |
González Pino, Iker Campos Celador, Álvaro Pérez Iribarren, Estibaliz Terés Zubiaga, Jon Sala Lizarraga, José María Pedro |
| author |
González Pino, Iker |
| author_facet |
González Pino, Iker Campos Celador, Álvaro Pérez Iribarren, Estibaliz Terés Zubiaga, Jon Sala Lizarraga, José María Pedro |
| author_role |
author |
| author2 |
Campos Celador, Álvaro Pérez Iribarren, Estibaliz Terés Zubiaga, Jon Sala Lizarraga, José María Pedro |
| author2_role |
author author author author |
| dc.subject.none.fl_str_mv |
stirling micro-CHP dynamic simulation viability single-family dwelling Spain |
| topic |
stirling micro-CHP dynamic simulation viability single-family dwelling Spain |
| description |
This paper analyses the operational and economic viability of Stirling engine-run micro-cogeneration units in single-family houses in Spain. Thermal demands for the reference dwelling, sited in three different and representative climatic zones, are obtained based on heating and domestic hot water requirements. By carrying out dynamic simulations of both the conventional and cogeneration installations, their performances are obtained and compared. Additionally, based on the results obtained in the simulations, economic viability of the Stirling engine-based micro-CHP is evaluated, taking into account Spanish regulation and economic framework, particularly fuel and electricity prices. Finally, a sensibility study is carried out in order to evaluate how economic results of these plants are affected by both variations in fuel and electricity prices as well as in initial investment costs. It is concluded that there is no opportunity for these devices to be feasible in new and retrofitted single-family dwellings sited in any climatic zone of Spain but in the coldest ones, where the micro-CHP plants could become viable if the Stirling engine investment cost decreases. |
| publishDate |
2013 |
| dc.date.none.fl_str_mv |
2013 2024 2024 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/10810/64656 |
| url |
http://hdl.handle.net/10810/64656 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
https://doi.org/10.1016/j.applthermaleng.2013.12.020 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by-nc-nd/4.0/ © 2013 Elsevier under CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/) |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-nd/4.0/ © 2013 Elsevier under CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/) |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Elsevier |
| publisher.none.fl_str_mv |
Elsevier |
| dc.source.none.fl_str_mv |
reponame:Addi. Archivo Digital para la Docencia y la Investigación instname:Universidad del País Vasco |
| instname_str |
Universidad del País Vasco |
| reponame_str |
Addi. Archivo Digital para la Docencia y la Investigación |
| collection |
Addi. Archivo Digital para la Docencia y la Investigación |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869417554339954688 |
| score |
15,301629 |