Electrochemical and structural evaluation of TiS2 as cathode material for calcium rechargable batteries

The experimental details on the data acquisition and data treatment are available at the article with DOI 10.1149/1945-7111/ab7a82

Detalhes bibliográficos
Autores: Black, Ashley P., Verrelli, Roberta, Palacín, M. Rosa
Tipo de documento: conjunto de datos
Data de publicação:2019
País:España
Recursos:Consejo Superior de Investigaciones Científicas (CSIC)
Repositório:DIGITAL.CSIC. Repositorio Institucional del CSIC
OAI Identifier:oai:digital.csic.es:10261/221376
Acesso em linha:http://hdl.handle.net/10261/221376
Access Level:Acceso aberto
Palavra-chave:Calcium battery
Calcium ferrites
Cathode material
X-ray diffraction
Electrochemistry
id ES_b3cf4151d80f6ff84e0c3c561e24d8f9
oai_identifier_str oai:digital.csic.es:10261/221376
network_acronym_str ES
network_name_str España
repository_id_str
spelling Electrochemical and structural evaluation of TiS2 as cathode material for calcium rechargable batteriesBlack, Ashley P.Verrelli, RobertaPalacín, M. RosaCalcium batteryCalcium ferritesCathode materialX-ray diffractionElectrochemistryThe experimental details on the data acquisition and data treatment are available at the article with DOI 10.1149/1945-7111/ab7a82This research was conducted under the innovation program H2020 FETOPEN-1-2016-2017 (CARBAT, grant agreement no. 766617). The objective of the CARBAT project is the development of a calcium metal rechargeable battery. This work aims to establish a reliable was to evaluate cathode active material for calcium reversible intercalation and shows the potential use of TiS2 as reversible cathode material for calcium batteries at room temperature.This dataset includes the electrochemical curves corresponding to a TiS2 cell cycled in 0.3 M Ca(TFSI)2 in PC electrolyte solution and tested at C/50 rate and at 60 °C. as well as x-ray diffraction data and the corresponding rietvel refinment pcr file of the reduced electrode samples.Peer reviewedBlack, Ashley P. [0000-0001-7929-5144]Verrelli, Roberta [0000-0001-7208-2760]Palacín, M. Rosa [0000-0001-7351-2005]Black, Ashley P.Verrelli, RobertaPalacín, M. RosaBlack, Ashley P.Verrelli, RobertaBlack, Ashley P.Verrelli, RobertaPalacín, M. RosaBlack, Ashley P.Verrelli, RobertaConsejo Superior de Investigaciones Científicas [https://ror.org/02gfc7t72]2019202020202020info:eu-repo/semantics/datasethttp://purl.org/coar/resource_type/c_ddb1The datasets are provided as txt files as well as in the original acquisition data format, EC-Lab raw data format for electrochemical data, pcr files for fullprof rietveld refinements and dat or xyn format for x-ray data. (35,48 MB)http://hdl.handle.net/10261/221376reponame:DIGITAL.CSIC. Repositorio Institucional del CSICinstname:Consejo Superior de Investigaciones Científicas (CSIC)Ingléshttp://dx.doi.org/10.1149/1945-7111/ab7a82; http://hdl.handle.net/10261/221377txt files can be plotted using any scientific graphing program. Alternatively, electrochemical data can be plotted by means of EC-Lab software and x-ray data can be visualized with free software available in the fullprof suite.Síinfo:eu-repo/semantics/openAccessoai:digital.csic.es:10261/2213762026-05-22T06:33:51Z
dc.title.none.fl_str_mv Electrochemical and structural evaluation of TiS2 as cathode material for calcium rechargable batteries
title Electrochemical and structural evaluation of TiS2 as cathode material for calcium rechargable batteries
spellingShingle Electrochemical and structural evaluation of TiS2 as cathode material for calcium rechargable batteries
Black, Ashley P.
Calcium battery
Calcium ferrites
Cathode material
X-ray diffraction
Electrochemistry
title_short Electrochemical and structural evaluation of TiS2 as cathode material for calcium rechargable batteries
title_full Electrochemical and structural evaluation of TiS2 as cathode material for calcium rechargable batteries
title_fullStr Electrochemical and structural evaluation of TiS2 as cathode material for calcium rechargable batteries
title_full_unstemmed Electrochemical and structural evaluation of TiS2 as cathode material for calcium rechargable batteries
title_sort Electrochemical and structural evaluation of TiS2 as cathode material for calcium rechargable batteries
dc.creator.none.fl_str_mv Black, Ashley P.
Verrelli, Roberta
Palacín, M. Rosa
author Black, Ashley P.
author_facet Black, Ashley P.
Verrelli, Roberta
Palacín, M. Rosa
author_role author
author2 Verrelli, Roberta
Palacín, M. Rosa
author2_role author
author
dc.contributor.none.fl_str_mv Black, Ashley P. [0000-0001-7929-5144]
Verrelli, Roberta [0000-0001-7208-2760]
Palacín, M. Rosa [0000-0001-7351-2005]
Black, Ashley P.
Verrelli, Roberta
Palacín, M. Rosa
Black, Ashley P.
Verrelli, Roberta
Black, Ashley P.
Verrelli, Roberta
Palacín, M. Rosa
Black, Ashley P.
Verrelli, Roberta
Consejo Superior de Investigaciones Científicas [https://ror.org/02gfc7t72]
dc.subject.none.fl_str_mv Calcium battery
Calcium ferrites
Cathode material
X-ray diffraction
Electrochemistry
topic Calcium battery
Calcium ferrites
Cathode material
X-ray diffraction
Electrochemistry
description The experimental details on the data acquisition and data treatment are available at the article with DOI 10.1149/1945-7111/ab7a82
publishDate 2019
dc.date.none.fl_str_mv 2019
2020
2020
2020
dc.type.none.fl_str_mv info:eu-repo/semantics/dataset
http://purl.org/coar/resource_type/c_ddb1
format dataset
dc.identifier.none.fl_str_mv http://hdl.handle.net/10261/221376
url http://hdl.handle.net/10261/221376
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv http://dx.doi.org/10.1149/1945-7111/ab7a82; http://hdl.handle.net/10261/221377
txt files can be plotted using any scientific graphing program. Alternatively, electrochemical data can be plotted by means of EC-Lab software and x-ray data can be visualized with free software available in the fullprof suite.

dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv The datasets are provided as txt files as well as in the original acquisition data format, EC-Lab raw data format for electrochemical data, pcr files for fullprof rietveld refinements and dat or xyn format for x-ray data. (35,48 MB)
dc.source.none.fl_str_mv reponame:DIGITAL.CSIC. Repositorio Institucional del CSIC
instname:Consejo Superior de Investigaciones Científicas (CSIC)
instname_str Consejo Superior de Investigaciones Científicas (CSIC)
reponame_str DIGITAL.CSIC. Repositorio Institucional del CSIC
collection DIGITAL.CSIC. Repositorio Institucional del CSIC
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869417207993204736
score 15,198674