Day-Ahead Contingency-Constrained Unit Commitment With Co-Optimized Post-Contingency Transmission Switching

This paper addresses the incorporation of transmission switching in the contingency-constrained unit commitment problem within the context of co-optimized electricity markets for energy and reserves. The proposed generation scheduling model differs from existing formulations due to the joint conside...

Descripción completa

Detalles Bibliográficos
Autores: Saavedra, Raphael, Street, Alexandre, Arroyo Sánchez, José Manuel
Tipo de recurso: artículo
Fecha de publicación:2020
País:España
Institución:Universidad de Castilla-La Mancha
Repositorio:RUIdeRA. Repositorio Institucional de la UCLM
OAI Identifier:oai:ruidera.uclm.es:10578/30122
Acceso en línea:http://hdl.handle.net/10578/30122
Access Level:acceso abierto
Palabra clave:Contingency-constrained unit commitment
Energy and reserve scheduling
Enhanced nested column-andconstraint generation
Post-contingency transmission switching
Compromiso de unidades con restricciones de contingencia
Programación de energía y reservas
Generación anidada mejorada con columnas y restricciones
Conmutación de la transmisión después de la contingencia
Descripción
Sumario:This paper addresses the incorporation of transmission switching in the contingency-constrained unit commitment problem within the context of co-optimized electricity markets for energy and reserves. The proposed generation scheduling model differs from existing formulations due to the joint consideration of four major complicating factors. First, transmission switching actions are considered both in the pre- and post-contingency states, thereby requiring binary post-contingency variables. Secondly, generation scheduling and transmission switching actions are co-optimized. In addition, the time-coupled operation of generating units is precisely characterized. Finally, practical features of modern power systems, such as uncertain nodal net injections and the operation of energy storage, are also considered. The proposed model is cast as a challenging mixed-integer program for which the off-the-shelf software customarily used for simpler models may lead to intractability even for moderately-sized instances. In order to circumvent this computational issue, this paper presents an enhanced and novel application of an exact nested column-and-constraint generation algorithm featuring the inclusion of valid constraints to improve the overall computational performance. Numerical simulations based on the IEEE 118- and 300-bus systems demonstrate the effective performance of the proposed approach as well as its economic and operational advantages over existing models disregarding post-contingency transmission switching.