Influence of ocular biometric factors on the defocus curve in an enlarged depth-of-focus intraocular lens

Background To assess the influence of biometric measurements on the defocus curve after the implantation of enlarged depth-of-focus (EDoF) intraocular lens (IOL). Methods Patients who underwent cataract surgery with bilateral implantation of Tecnis Symfony IOL were enrolled. Preoperatively, axial le...

Descripción completa

Detalles Bibliográficos
Autores: Giménez Calvo, Galadriel, Bartol Puyal, Francisco de Asís, Altemir, Irene, Méndez Martínez, Silvia, Almenara, Cristina, Soriano Pina, Diana, Murueta-Goyena Larrañaga, Ane, Larrosa, Manuel
Tipo de recurso: artículo
Fecha de publicación:2023
País:España
Institución:Universidad del País Vasco
Repositorio:Addi. Archivo Digital para la Docencia y la Investigación
OAI Identifier:oai:addi.ehu.eus:10810/61797
Acceso en línea:http://hdl.handle.net/10810/61797
Access Level:acceso abierto
Palabra clave:multifocal IOLs
EDoF IOLs
diffractive
cataract
quality of vision
Descripción
Sumario:Background To assess the influence of biometric measurements on the defocus curve after the implantation of enlarged depth-of-focus (EDoF) intraocular lens (IOL). Methods Patients who underwent cataract surgery with bilateral implantation of Tecnis Symfony IOL were enrolled. Preoperatively, axial length (AL), corneal keratometry (K), pupil size and corneal aberrations were measured. 1 month after surgery, distance, intermediate, and near visual acuities (VA) were recorded. At 3 months, monocular and binocular corrected contrast sensitivities under photopic and mesopic lighting conditions were measured with CSV-1000E test. At 6-months, the defocus curve between −5.00 to + 3.00 diopters (D) was assessed in steps of 0.50 D, and NEI-RQL-42 questionnaire was administered. Results One hundred thirty one eyes of 66 patients were included. Binocular logMAR VA better than 0.1 for intermediate vision was obtained in 90% of patients, whereas only 17.7% obtained that result in near vision. The rate of satisfaction was high (96%) and most of them (85.5%) had no or little difficulties in near vision. The mean amplitude of the defocus curve was 2.35D ± 0.73D, and smaller AL, smaller pupils, younger age, and male sex were associated with wider range of clear vision. Conclusions Tecnis Symfony IOL enables functional vision at all distances, but demographic variables and preoperative biometric measurements like AL and pupil size influence the postoperative amplitude of the defocus curve. These parameters could be used to predict the performance of EDoF IOLs.