Glutathione modified screen-printed carbon nanofiber electrode for the voltammetric determination of metal ions in natural samples

This work reports the development of a glutathione modified electrode via electrografting on a screen-printed carbon nanofiber substrate (GSH-SPCNFE). GSH-SPCNFE was compared to a classical screen-printed carbon electrode modified with glutathione (GSH-SPCE) for the simultaneous voltammetric determi...

Descripción completa

Detalles Bibliográficos
Autores: Pérez Ràfols, Clara, Serrano i Plana, Núria, Díaz Cruz, José Manuel, Ariño Blasco, Cristina, Esteban i Cortada, Miquel
Tipo de recurso: artículo
Estado:Versión aceptada para publicación
Fecha de publicación:2016
País:España
Institución:Universidad de Barcelona
Repositorio:Dipòsit Digital de la UB
OAI Identifier:oai:diposit.ub.edu:2445/125482
Acceso en línea:https://hdl.handle.net/2445/125482
Access Level:acceso abierto
Palabra clave:Glutatió
Voltametria
Metalls pesants
Glutathione
Voltammetry
Heavy metals
id ES_b284ff4eaf753c40e329e5bbbdc455fd
oai_identifier_str oai:diposit.ub.edu:2445/125482
network_acronym_str ES
network_name_str España
repository_id_str
spelling Glutathione modified screen-printed carbon nanofiber electrode for the voltammetric determination of metal ions in natural samplesPérez Ràfols, ClaraSerrano i Plana, NúriaDíaz Cruz, José ManuelAriño Blasco, CristinaEsteban i Cortada, MiquelGlutatióVoltametriaMetalls pesantsGlutathioneVoltammetryHeavy metalsThis work reports the development of a glutathione modified electrode via electrografting on a screen-printed carbon nanofiber substrate (GSH-SPCNFE). GSH-SPCNFE was compared to a classical screen-printed carbon electrode modified with glutathione (GSH-SPCE) for the simultaneous voltammetric determination of Cd(II) and Pb(II). Their electrochemical characterization and analytical performance suggest that SPCNFE could be a much better support for GSH immobilization. The applicability of GSH-SPCNFE for the determination of low concentration levels of Pb(II) and Cd(II) ions in environmental samples was successfully tested in a certified wastewater reference material by means of stripping voltammetry with a very high reproducibility and good trueness.Elsevier B.V.2016info:eu-repo/semantics/articleinfo:eu-repo/semantics/acceptedVersionapplication/pdfhttps://hdl.handle.net/2445/125482Articles publicats en revistes (Enginyeria Química i Química Analítica)reponame:Dipòsit Digital de la UBinstname:Universidad de BarcelonaInglésVersió postprint del document publicat a: https://doi.org/10.1016/j.talanta.2016.04.011Talanta, 2016, vol. 155, p. 8-13https://doi.org/10.1016/j.talanta.2016.04.011cc-by-nc-nd (c) Elsevier B.V., 2016http://creativecommons.org/licenses/by-nc-nd/3.0/esinfo:eu-repo/semantics/openAccessoai:diposit.ub.edu:2445/1254822026-05-27T06:46:51Z
dc.title.none.fl_str_mv Glutathione modified screen-printed carbon nanofiber electrode for the voltammetric determination of metal ions in natural samples
title Glutathione modified screen-printed carbon nanofiber electrode for the voltammetric determination of metal ions in natural samples
spellingShingle Glutathione modified screen-printed carbon nanofiber electrode for the voltammetric determination of metal ions in natural samples
Pérez Ràfols, Clara
Glutatió
Voltametria
Metalls pesants
Glutathione
Voltammetry
Heavy metals
title_short Glutathione modified screen-printed carbon nanofiber electrode for the voltammetric determination of metal ions in natural samples
title_full Glutathione modified screen-printed carbon nanofiber electrode for the voltammetric determination of metal ions in natural samples
title_fullStr Glutathione modified screen-printed carbon nanofiber electrode for the voltammetric determination of metal ions in natural samples
title_full_unstemmed Glutathione modified screen-printed carbon nanofiber electrode for the voltammetric determination of metal ions in natural samples
title_sort Glutathione modified screen-printed carbon nanofiber electrode for the voltammetric determination of metal ions in natural samples
dc.creator.none.fl_str_mv Pérez Ràfols, Clara
Serrano i Plana, Núria
Díaz Cruz, José Manuel
Ariño Blasco, Cristina
Esteban i Cortada, Miquel
author Pérez Ràfols, Clara
author_facet Pérez Ràfols, Clara
Serrano i Plana, Núria
Díaz Cruz, José Manuel
Ariño Blasco, Cristina
Esteban i Cortada, Miquel
author_role author
author2 Serrano i Plana, Núria
Díaz Cruz, José Manuel
Ariño Blasco, Cristina
Esteban i Cortada, Miquel
author2_role author
author
author
author
dc.subject.none.fl_str_mv Glutatió
Voltametria
Metalls pesants
Glutathione
Voltammetry
Heavy metals
topic Glutatió
Voltametria
Metalls pesants
Glutathione
Voltammetry
Heavy metals
description This work reports the development of a glutathione modified electrode via electrografting on a screen-printed carbon nanofiber substrate (GSH-SPCNFE). GSH-SPCNFE was compared to a classical screen-printed carbon electrode modified with glutathione (GSH-SPCE) for the simultaneous voltammetric determination of Cd(II) and Pb(II). Their electrochemical characterization and analytical performance suggest that SPCNFE could be a much better support for GSH immobilization. The applicability of GSH-SPCNFE for the determination of low concentration levels of Pb(II) and Cd(II) ions in environmental samples was successfully tested in a certified wastewater reference material by means of stripping voltammetry with a very high reproducibility and good trueness.
publishDate 2016
dc.date.none.fl_str_mv 2016
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/acceptedVersion
format article
status_str acceptedVersion
dc.identifier.none.fl_str_mv https://hdl.handle.net/2445/125482
url https://hdl.handle.net/2445/125482
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv Versió postprint del document publicat a: https://doi.org/10.1016/j.talanta.2016.04.011
Talanta, 2016, vol. 155, p. 8-13
https://doi.org/10.1016/j.talanta.2016.04.011
dc.rights.none.fl_str_mv cc-by-nc-nd (c) Elsevier B.V., 2016
http://creativecommons.org/licenses/by-nc-nd/3.0/es
info:eu-repo/semantics/openAccess
rights_invalid_str_mv cc-by-nc-nd (c) Elsevier B.V., 2016
http://creativecommons.org/licenses/by-nc-nd/3.0/es
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier B.V.
publisher.none.fl_str_mv Elsevier B.V.
dc.source.none.fl_str_mv Articles publicats en revistes (Enginyeria Química i Química Analítica)
reponame:Dipòsit Digital de la UB
instname:Universidad de Barcelona
instname_str Universidad de Barcelona
reponame_str Dipòsit Digital de la UB
collection Dipòsit Digital de la UB
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869417061192564736
score 15,300724