Environmental and life cycle cost analysis of one switched reluctance motor drive and two inverter-fed induction motor drives
Herein is described an environmental and life cycle cost (LCC) analysis of one switched reluctance motor (SRM) drive and two inverter-fed induction motor (IM) drives. The two types of drives are compared based on critical reasoning, and European Commission (EC) Regulation 640/2009 is considered. Env...
| Autores: | , , , , , |
|---|---|
| Tipo de documento: | artigo |
| Data de publicação: | 2012 |
| País: | España |
| Recursos: | Universitat Politècnica de Catalunya (UPC) |
| Repositório: | UPCommons. Portal del coneixement obert de la UPC |
| Idioma: | inglês |
| OAI Identifier: | oai:upcommons.upc.edu:2117/16717 |
| Acesso em linha: | https://hdl.handle.net/2117/16717 https://dx.doi.org/10.1049/iet-epa.2011.0320 |
| Access Level: | Acceso aberto |
| Palavra-chave: | Electric motors, Induction Motors elèctrics d'inducció Cicle de vida del producte -- Aspectes ambientals Cicle de vida del producte -- Avaluació Àrees temàtiques de la UPC::Desenvolupament humà i sostenible Àrees temàtiques de la UPC::Enginyeria mecànica::Motors::Motors elèctrics |
| Resumo: | Herein is described an environmental and life cycle cost (LCC) analysis of one switched reluctance motor (SRM) drive and two inverter-fed induction motor (IM) drives. The two types of drives are compared based on critical reasoning, and European Commission (EC) Regulation 640/2009 is considered. Environmental impact and LCC were evaluated according the Methodology for the Ecodesign of Energy-Using Products and accounting different operation conditions. The SRM drive was found to have less environmental impact than were the IM drives |
|---|