Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake‑time movement behaviours using the ActivPAL3 in nursing home residents

Introduction Scarce evidence is available about the minimum number of valid days wearing the activPAL3 to obtain a precise estimate of sedentary behaviour (SB) and awake-time movement behaviours (ATMB) in nursing home (NH) residents. The study aimed to determine the minimum number of valid days requ...

Descripción completa

Detalles Bibliográficos
Autores: Farrés-Godayol, Pau, Ruiz-Díaz, Miguel Ángel, Dall, Philippa, Skelton, Dawn A., Minobes, Eduard, Jerez-Roig, Javier, Giné-Garriga, Maria
Tipo de recurso: artículo
Fecha de publicación:2023
País:España
Institución:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
Repositorio:Recercat. Dipósit de la Recerca de Catalunya
OAI Identifier:oai:recercat.cat:20.500.14342/3685
Acceso en línea:http://hdl.handle.net/20.500.14342/3685
https://doi.org/10.1186/s11556-023-00329-0
Access Level:acceso abierto
Palabra clave:Residències de persones grans
Persones grans--Assistència institucional
Sedentarisme
id ES_b043b726da0e15e32fdeb3adbcba63f5
oai_identifier_str oai:recercat.cat:20.500.14342/3685
network_acronym_str ES
network_name_str España
repository_id_str
spelling Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake‑time movement behaviours using the ActivPAL3 in nursing home residentsFarrés-Godayol, PauRuiz-Díaz, Miguel ÁngelDall, PhilippaSkelton, Dawn A.Minobes, EduardJerez-Roig, JavierGiné-Garriga, MariaResidències de persones gransPersones grans--Assistència institucionalSedentarismeIntroduction Scarce evidence is available about the minimum number of valid days wearing the activPAL3 to obtain a precise estimate of sedentary behaviour (SB) and awake-time movement behaviours (ATMB) in nursing home (NH) residents. The study aimed to determine the minimum number of valid days required for accurately estimate SB and ATMB using the activPAL3 device in NH residents. It also investigated how the starting point of a day (the 24-h period) impacted reliability. Methods Participants wore an activPAL3 for 7 consecutive days. The data was classifed in two-time blocks (00:00 Ante Meridiem (AM)—00:00 AM midnight vs 12:00 Post Meridiam (PM) -12:00 PM midday) and the sample was strati‑ fed into two groups according to their capacity to stand and walk, to examine if timing of sampling or physical functioning afected minimum wear time. SB, ATMB, sociodemographic, and health-related variables were collected. Sensitivity of the time-blocks were tested through the dispersion frequencies and diferences between blocks through Kolmogorov–Smirnov test for normality; parametric variables through two-related means T-test and Wil‑ coxon test for non-parametric data. Reliability was assessed with the Cronbach’s Alpha and the intra-class correlation coefcient (ICC), using a one-factor model estimating the reliability for each measurement day loading in the same latent factor. Results Ninety-fve NH residents (81.1% women; age=85.8±7.2 years) were included. The midnight block had higher reliability, sensitivity and no statistically signifcant diferences between days were found. At least three consecutive days of monitoring were necessary to achieve a reliability of ICC≥0.8 for those NH residents able to stand and walk and six days for those unable. Conclusions NH residents who are able to stand and walk require a minimum of three consecutive days wear‑ ing the device, while those who are unable require at least six days due to their highly homogenous daily routines and sensitivity to PA events. Regardless of the activPAL3 recording start time, data processing should reference the midnight time block.info:eu-repo/semantics/publishedVersionBMCUniversitat Ramon Llull. Facultat de Psicologia, Ciències de l'Educació i de l'Esport Blanquerna2023info:eu-repo/semantics/article17http://hdl.handle.net/20.500.14342/3685https://doi.org/10.1186/s11556-023-00329-0reponame:Recercat. Dipósit de la Recerca de Catalunyainstname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)InglésEuropean Review of Aging and Physical Activity, 2023, 20:19info:eu-repo/grantAgreement/UIC/BI-CHAISS-2019/003info:eu-repo/grantAgreement/COPC/R03/19© L'autor/aAttribution 4.0 Internationalhttp://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:recercat.cat:20.500.14342/36852026-05-29T05:05:01Z
dc.title.none.fl_str_mv Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake‑time movement behaviours using the ActivPAL3 in nursing home residents
title Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake‑time movement behaviours using the ActivPAL3 in nursing home residents
spellingShingle Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake‑time movement behaviours using the ActivPAL3 in nursing home residents
Farrés-Godayol, Pau
Residències de persones grans
Persones grans--Assistència institucional
Sedentarisme
title_short Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake‑time movement behaviours using the ActivPAL3 in nursing home residents
title_full Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake‑time movement behaviours using the ActivPAL3 in nursing home residents
title_fullStr Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake‑time movement behaviours using the ActivPAL3 in nursing home residents
title_full_unstemmed Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake‑time movement behaviours using the ActivPAL3 in nursing home residents
title_sort Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake‑time movement behaviours using the ActivPAL3 in nursing home residents
dc.creator.none.fl_str_mv Farrés-Godayol, Pau
Ruiz-Díaz, Miguel Ángel
Dall, Philippa
Skelton, Dawn A.
Minobes, Eduard
Jerez-Roig, Javier
Giné-Garriga, Maria
author Farrés-Godayol, Pau
author_facet Farrés-Godayol, Pau
Ruiz-Díaz, Miguel Ángel
Dall, Philippa
Skelton, Dawn A.
Minobes, Eduard
Jerez-Roig, Javier
Giné-Garriga, Maria
author_role author
author2 Ruiz-Díaz, Miguel Ángel
Dall, Philippa
Skelton, Dawn A.
Minobes, Eduard
Jerez-Roig, Javier
Giné-Garriga, Maria
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universitat Ramon Llull. Facultat de Psicologia, Ciències de l'Educació i de l'Esport Blanquerna
dc.subject.none.fl_str_mv Residències de persones grans
Persones grans--Assistència institucional
Sedentarisme
topic Residències de persones grans
Persones grans--Assistència institucional
Sedentarisme
description Introduction Scarce evidence is available about the minimum number of valid days wearing the activPAL3 to obtain a precise estimate of sedentary behaviour (SB) and awake-time movement behaviours (ATMB) in nursing home (NH) residents. The study aimed to determine the minimum number of valid days required for accurately estimate SB and ATMB using the activPAL3 device in NH residents. It also investigated how the starting point of a day (the 24-h period) impacted reliability. Methods Participants wore an activPAL3 for 7 consecutive days. The data was classifed in two-time blocks (00:00 Ante Meridiem (AM)—00:00 AM midnight vs 12:00 Post Meridiam (PM) -12:00 PM midday) and the sample was strati‑ fed into two groups according to their capacity to stand and walk, to examine if timing of sampling or physical functioning afected minimum wear time. SB, ATMB, sociodemographic, and health-related variables were collected. Sensitivity of the time-blocks were tested through the dispersion frequencies and diferences between blocks through Kolmogorov–Smirnov test for normality; parametric variables through two-related means T-test and Wil‑ coxon test for non-parametric data. Reliability was assessed with the Cronbach’s Alpha and the intra-class correlation coefcient (ICC), using a one-factor model estimating the reliability for each measurement day loading in the same latent factor. Results Ninety-fve NH residents (81.1% women; age=85.8±7.2 years) were included. The midnight block had higher reliability, sensitivity and no statistically signifcant diferences between days were found. At least three consecutive days of monitoring were necessary to achieve a reliability of ICC≥0.8 for those NH residents able to stand and walk and six days for those unable. Conclusions NH residents who are able to stand and walk require a minimum of three consecutive days wear‑ ing the device, while those who are unable require at least six days due to their highly homogenous daily routines and sensitivity to PA events. Regardless of the activPAL3 recording start time, data processing should reference the midnight time block.
publishDate 2023
dc.date.none.fl_str_mv 2023
dc.type.none.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv http://hdl.handle.net/20.500.14342/3685
https://doi.org/10.1186/s11556-023-00329-0
url http://hdl.handle.net/20.500.14342/3685
https://doi.org/10.1186/s11556-023-00329-0
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv European Review of Aging and Physical Activity, 2023, 20:19
info:eu-repo/grantAgreement/UIC/BI-CHAISS-2019/003
info:eu-repo/grantAgreement/COPC/R03/19
dc.rights.none.fl_str_mv © L'autor/a
Attribution 4.0 International
http://creativecommons.org/licenses/by/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv © L'autor/a
Attribution 4.0 International
http://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 17
dc.publisher.none.fl_str_mv BMC
publisher.none.fl_str_mv BMC
dc.source.none.fl_str_mv reponame:Recercat. Dipósit de la Recerca de Catalunya
instname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
instname_str Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
reponame_str Recercat. Dipósit de la Recerca de Catalunya
collection Recercat. Dipósit de la Recerca de Catalunya
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869416793406177280
score 15,812429