Modified Geometry of 106Ru Asymmetric Eye Plaques to Improve Dosimetric Calculations in Ophthalmic Brachytherapy
Ru/Rh asymmetric plaques for ophthalmic brachytherapy have special geometric designs with a cutout intended to prevent irradiation of critical ocular structures proximal to the tumor. In this work, we present new geometric models for PENELOPE+PenEasy Monte Carlo simulations of these applicators, dif...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2022 |
| País: | España |
| Institución: | Consejo Superior de Investigaciones Científicas (CSIC) |
| Repositorio: | DIGITAL.CSIC. Repositorio Institucional del CSIC |
| OAI Identifier: | oai:digital.csic.es:10261/306792 |
| Acceso en línea: | http://hdl.handle.net/10261/306792 https://api.elsevier.com/content/abstract/scopus_id/85131848810 |
| Access Level: | acceso abierto |
| Palabra clave: | Monte Carlo Ophthalmic brachytherapy Ruthenium plaque |
| id |
ES_afc337d8e29a850adeb8d00a9f16aad2 |
|---|---|
| oai_identifier_str |
oai:digital.csic.es:10261/306792 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Modified Geometry of 106Ru Asymmetric Eye Plaques to Improve Dosimetric Calculations in Ophthalmic BrachytherapyMiras, HéctorTerrón, José AntonioBertolet, AlejandroLeal, AntonioMonte CarloOphthalmic brachytherapyRuthenium plaqueRu/Rh asymmetric plaques for ophthalmic brachytherapy have special geometric designs with a cutout intended to prevent irradiation of critical ocular structures proximal to the tumor. In this work, we present new geometric models for PENELOPE+PenEasy Monte Carlo simulations of these applicators, differing from the vendor-reported geometry, that better match their real geometry to assess their dosimetric impact. Simulation results were benchmarked to experimental dosimetric data from radiochromic film measurements, data provided by the manufacturer in the calibration certificates, and other experimental results published in the literature, obtaining, in all cases, better agreement with the modified geometries. The clinical impact of the new geometric models was evaluated by simulating real clinical cases using patient-specific eye models. The cases calculated using the modified geometries presented higher doses to the critical structures proximal to the cutout region. The modified geometric models presented in this work provide a more accurate representation of the asymmetric plaques, greatly improving the agreement between Monte Carlo calculations and experimental measurements. Lack of consideration of accurate geometric models has been shown to be translated into notable increases in dose to organs at risk in clinical cases.The APC was funded by Fundación Pública Andaluza para la Gestión de la Investigación en Salud de Sevilla (FISEVI). Alejandro Bertolet is funded by the NIH/NCI award K99 CA267560.Peer reviewedMultidisciplinary Digital Publishing InstituteFundación Pública Andaluza para la Gestión de la Investigación en Salud de SevillaConsejo Superior de Investigaciones Científicas [https://ror.org/02gfc7t72]202320232022info:eu-repo/semantics/articlehttp://purl.org/coar/resource_type/c_6501Publisher's versioninfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/10261/306792https://api.elsevier.com/content/abstract/scopus_id/85131848810reponame:DIGITAL.CSIC. Repositorio Institucional del CSICinstname:Consejo Superior de Investigaciones Científicas (CSIC)Ingléshttps://doi.org/10.3390/jpm12050723Síinfo:eu-repo/semantics/openAccessoai:digital.csic.es:10261/3067922026-05-22T06:33:51Z |
| dc.title.none.fl_str_mv |
Modified Geometry of 106Ru Asymmetric Eye Plaques to Improve Dosimetric Calculations in Ophthalmic Brachytherapy |
| title |
Modified Geometry of 106Ru Asymmetric Eye Plaques to Improve Dosimetric Calculations in Ophthalmic Brachytherapy |
| spellingShingle |
Modified Geometry of 106Ru Asymmetric Eye Plaques to Improve Dosimetric Calculations in Ophthalmic Brachytherapy Miras, Héctor Monte Carlo Ophthalmic brachytherapy Ruthenium plaque |
| title_short |
Modified Geometry of 106Ru Asymmetric Eye Plaques to Improve Dosimetric Calculations in Ophthalmic Brachytherapy |
| title_full |
Modified Geometry of 106Ru Asymmetric Eye Plaques to Improve Dosimetric Calculations in Ophthalmic Brachytherapy |
| title_fullStr |
Modified Geometry of 106Ru Asymmetric Eye Plaques to Improve Dosimetric Calculations in Ophthalmic Brachytherapy |
| title_full_unstemmed |
Modified Geometry of 106Ru Asymmetric Eye Plaques to Improve Dosimetric Calculations in Ophthalmic Brachytherapy |
| title_sort |
Modified Geometry of 106Ru Asymmetric Eye Plaques to Improve Dosimetric Calculations in Ophthalmic Brachytherapy |
| dc.creator.none.fl_str_mv |
Miras, Héctor Terrón, José Antonio Bertolet, Alejandro Leal, Antonio |
| author |
Miras, Héctor |
| author_facet |
Miras, Héctor Terrón, José Antonio Bertolet, Alejandro Leal, Antonio |
| author_role |
author |
| author2 |
Terrón, José Antonio Bertolet, Alejandro Leal, Antonio |
| author2_role |
author author author |
| dc.contributor.none.fl_str_mv |
Fundación Pública Andaluza para la Gestión de la Investigación en Salud de Sevilla Consejo Superior de Investigaciones Científicas [https://ror.org/02gfc7t72] |
| dc.subject.none.fl_str_mv |
Monte Carlo Ophthalmic brachytherapy Ruthenium plaque |
| topic |
Monte Carlo Ophthalmic brachytherapy Ruthenium plaque |
| description |
Ru/Rh asymmetric plaques for ophthalmic brachytherapy have special geometric designs with a cutout intended to prevent irradiation of critical ocular structures proximal to the tumor. In this work, we present new geometric models for PENELOPE+PenEasy Monte Carlo simulations of these applicators, differing from the vendor-reported geometry, that better match their real geometry to assess their dosimetric impact. Simulation results were benchmarked to experimental dosimetric data from radiochromic film measurements, data provided by the manufacturer in the calibration certificates, and other experimental results published in the literature, obtaining, in all cases, better agreement with the modified geometries. The clinical impact of the new geometric models was evaluated by simulating real clinical cases using patient-specific eye models. The cases calculated using the modified geometries presented higher doses to the critical structures proximal to the cutout region. The modified geometric models presented in this work provide a more accurate representation of the asymmetric plaques, greatly improving the agreement between Monte Carlo calculations and experimental measurements. Lack of consideration of accurate geometric models has been shown to be translated into notable increases in dose to organs at risk in clinical cases. |
| publishDate |
2022 |
| dc.date.none.fl_str_mv |
2022 2023 2023 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article http://purl.org/coar/resource_type/c_6501 Publisher's version info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/10261/306792 https://api.elsevier.com/content/abstract/scopus_id/85131848810 |
| url |
http://hdl.handle.net/10261/306792 https://api.elsevier.com/content/abstract/scopus_id/85131848810 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
https://doi.org/10.3390/jpm12050723 Sí |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Multidisciplinary Digital Publishing Institute |
| publisher.none.fl_str_mv |
Multidisciplinary Digital Publishing Institute |
| dc.source.none.fl_str_mv |
reponame:DIGITAL.CSIC. Repositorio Institucional del CSIC instname:Consejo Superior de Investigaciones Científicas (CSIC) |
| instname_str |
Consejo Superior de Investigaciones Científicas (CSIC) |
| reponame_str |
DIGITAL.CSIC. Repositorio Institucional del CSIC |
| collection |
DIGITAL.CSIC. Repositorio Institucional del CSIC |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869416712003125248 |
| score |
15,812429 |