Reliability of Xsens inertial measurement unit in measuring trunk accelerations: a sex-based differences study during incremental treadmill running

Introduction: Inertial measurement units (IMUs) are utilized to measure trunk acceleration variables related to both running performances and rehabilitation purposes. This study examined both the reliability and sex-based differences of these variables during an incremental treadmill running test. M...

Descripción completa

Detalles Bibliográficos
Autores: Miqueleiz Erburu, Unai, Aguado Jiménez, Roberto, Lecumberri Villamediana, Pablo, García-Tabar, Ibai, Gorostiaga Ayestarán, Esteban
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2024
País:España
Institución:Universidad Pública de Navarra
Repositorio:Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
OAI Identifier:oai:academica-e.unavarra.es:2454/51550
Acceso en línea:https://hdl.handle.net/2454/51550
Access Level:acceso abierto
Palabra clave:Biomechanics
Endurance athletes
Inertial sensor
Treadmill running
Wearable
id ES_aee0152f87dbcefefdd24e43f4e841e6
oai_identifier_str oai:academica-e.unavarra.es:2454/51550
network_acronym_str ES
network_name_str España
repository_id_str
spelling Reliability of Xsens inertial measurement unit in measuring trunk accelerations: a sex-based differences study during incremental treadmill runningMiqueleiz Erburu, UnaiAguado Jiménez, RobertoLecumberri Villamediana, PabloGarcía-Tabar, IbaiGorostiaga Ayestarán, EstebanBiomechanicsEndurance athletesInertial sensorTreadmill runningWearableIntroduction: Inertial measurement units (IMUs) are utilized to measure trunk acceleration variables related to both running performances and rehabilitation purposes. This study examined both the reliability and sex-based differences of these variables during an incremental treadmill running test. Methods: Eighteen endurance runners performed a test–retest on different days, and 30 runners (15 females) were recruited to analyze sex-based differences. Mediolateral (ML) and vertical (VT) trunk displacement and root mean square (RMS) accelerations were analyzed at 9, 15, and 21 km·h−1. Results: No significant differences were found between test-retests [effect size (ES)<0.50)]. Higher intraclass correlation coefficients (ICCs) were found in the trunk displacement (0.85-0.96) compared to the RMS-based variables (0.71–0.94). Male runners showed greater VT displacement (ES = 0.90–1.0), while female runners displayed greater ML displacement, RMS ML and anteroposterior (AP), and resultant euclidean scalar (RES) (ES = 0.83–1.9). Discussion: The IMU was found reliable for the analysis of the studied trunk acceleration-based variables. This is the first study that reports different results concerning acceleration (RMS) and trunk displacement variables for a same axis in the analysis of sex-based differences.Frontiers MediaCiencias de la SaludOsasun Zientziak2024info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://hdl.handle.net/2454/51550reponame:Academica-e. Repositorio Institucional de la Universidad Pública de Navarrainstname:Universidad Pública de NavarraInglés© 2024 Miqueleiz, Aguado-Jimenez, Lecumberri, Garcia-Tabar and Gorostiaga. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY).https://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:academica-e.unavarra.es:2454/515502026-06-17T12:41:47Z
dc.title.none.fl_str_mv Reliability of Xsens inertial measurement unit in measuring trunk accelerations: a sex-based differences study during incremental treadmill running
title Reliability of Xsens inertial measurement unit in measuring trunk accelerations: a sex-based differences study during incremental treadmill running
spellingShingle Reliability of Xsens inertial measurement unit in measuring trunk accelerations: a sex-based differences study during incremental treadmill running
Miqueleiz Erburu, Unai
Biomechanics
Endurance athletes
Inertial sensor
Treadmill running
Wearable
title_short Reliability of Xsens inertial measurement unit in measuring trunk accelerations: a sex-based differences study during incremental treadmill running
title_full Reliability of Xsens inertial measurement unit in measuring trunk accelerations: a sex-based differences study during incremental treadmill running
title_fullStr Reliability of Xsens inertial measurement unit in measuring trunk accelerations: a sex-based differences study during incremental treadmill running
title_full_unstemmed Reliability of Xsens inertial measurement unit in measuring trunk accelerations: a sex-based differences study during incremental treadmill running
title_sort Reliability of Xsens inertial measurement unit in measuring trunk accelerations: a sex-based differences study during incremental treadmill running
dc.creator.none.fl_str_mv Miqueleiz Erburu, Unai
Aguado Jiménez, Roberto
Lecumberri Villamediana, Pablo
García-Tabar, Ibai
Gorostiaga Ayestarán, Esteban
author Miqueleiz Erburu, Unai
author_facet Miqueleiz Erburu, Unai
Aguado Jiménez, Roberto
Lecumberri Villamediana, Pablo
García-Tabar, Ibai
Gorostiaga Ayestarán, Esteban
author_role author
author2 Aguado Jiménez, Roberto
Lecumberri Villamediana, Pablo
García-Tabar, Ibai
Gorostiaga Ayestarán, Esteban
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Ciencias de la Salud
Osasun Zientziak
dc.subject.none.fl_str_mv Biomechanics
Endurance athletes
Inertial sensor
Treadmill running
Wearable
topic Biomechanics
Endurance athletes
Inertial sensor
Treadmill running
Wearable
description Introduction: Inertial measurement units (IMUs) are utilized to measure trunk acceleration variables related to both running performances and rehabilitation purposes. This study examined both the reliability and sex-based differences of these variables during an incremental treadmill running test. Methods: Eighteen endurance runners performed a test–retest on different days, and 30 runners (15 females) were recruited to analyze sex-based differences. Mediolateral (ML) and vertical (VT) trunk displacement and root mean square (RMS) accelerations were analyzed at 9, 15, and 21 km·h−1. Results: No significant differences were found between test-retests [effect size (ES)<0.50)]. Higher intraclass correlation coefficients (ICCs) were found in the trunk displacement (0.85-0.96) compared to the RMS-based variables (0.71–0.94). Male runners showed greater VT displacement (ES = 0.90–1.0), while female runners displayed greater ML displacement, RMS ML and anteroposterior (AP), and resultant euclidean scalar (RES) (ES = 0.83–1.9). Discussion: The IMU was found reliable for the analysis of the studied trunk acceleration-based variables. This is the first study that reports different results concerning acceleration (RMS) and trunk displacement variables for a same axis in the analysis of sex-based differences.
publishDate 2024
dc.date.none.fl_str_mv 2024
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://hdl.handle.net/2454/51550
url https://hdl.handle.net/2454/51550
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.rights.none.fl_str_mv https://creativecommons.org/licenses/by/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Frontiers Media
publisher.none.fl_str_mv Frontiers Media
dc.source.none.fl_str_mv reponame:Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
instname:Universidad Pública de Navarra
instname_str Universidad Pública de Navarra
reponame_str Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
collection Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869416618173399040
score 15,81155