Incidence of arrhythmias in a large cohort of patients with current implantable cardioverter-defibrillators in Spain: results from the UMBRELLA Registry

The benefit of implantable cardioverter-defibrillators (ICDs) in patients at risk of sudden death has been established in randomized clinical trials (RCTs) using the ICD models available at the time. However, observational large-scale data on the incidence of arrhythmias in up-to-date ICDs implanted...

Descripción completa

Detalles Bibliográficos
Autores: Fontenla, A, Martinez-Ferrer, JB, Alzueta, J, Vinolas, X, Garcia-Alberola, A, Brugada, J, Peinado, R, Sancho-Tello, MJ, Cano, A, Fernandez-Lozano, I
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2016
País:España
Institución:Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau)
Repositorio:r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
OAI Identifier:oai:iibsantpau.fundanetsuite.com:p6923
Acceso en línea:https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=6923
Access Level:acceso abierto
Palabra clave:Ventricular arrhythmias
Implantable cardioverter-defibrillator
Inappropriate shocks
Appropriate shocks
id ES_aeccd89671bef4f700a3604e7e4f0346
oai_identifier_str oai:iibsantpau.fundanetsuite.com:p6923
network_acronym_str ES
network_name_str España
repository_id_str
spelling Incidence of arrhythmias in a large cohort of patients with current implantable cardioverter-defibrillators in Spain: results from the UMBRELLA RegistryFontenla, AMartinez-Ferrer, JBAlzueta, JVinolas, XGarcia-Alberola, ABrugada, JPeinado, RSancho-Tello, MJCano, AFernandez-Lozano, IVentricular arrhythmiasImplantable cardioverter-defibrillatorInappropriate shocksAppropriate shocksThe benefit of implantable cardioverter-defibrillators (ICDs) in patients at risk of sudden death has been established in randomized clinical trials (RCTs) using the ICD models available at the time. However, observational large-scale data on the incidence of arrhythmias in up-to-date ICDs implanted according to the current guidelines are scarce. The aim was to assess the incidence of arrhythmias in a large, current ICD population based on a blinded peer review of the detected episodes. UMBRELLA is a multicentre, observational registry of ICD patients followed by remote monitoring. Stored episodes were classified by a blinded committee of experts. Subgroup analyses were based on clinical profiles established by previous pivotal RCTs of ICDs. Of 1514 enrolled patients, 605 (39.9%) patients had 5951 episodes after 26 +/- 17 months follow-up, being 3353 of them (56.3%) sustained ventricular arrhythmias (SVA), and 13.2% of SVA were self-terminated. Appropriate and inappropriate shocks occurred in 11.6 and 5% of patients, respectively. The 3 years cumulative incidence of SVA was 25% (95% CI: 21-28%) in primary prevention patients and 41% (95% CI: 36-47%) in secondary prevention patients (P < 0.001). Male gender, secondary prevention, and atrial fibrillation as basal rhythm were significantly related to a higher incidence of SVA. This real-world analysis suggests that modern ICD patients have a low rate of appropriate and inappropriate shocks. The risk of SVA in secondary prevention patients is less than what has been reported in RCTs.OXFORD UNIV PRESS2016info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionhttps://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=6923EUROPACEISSN: 10995129ISSNe: 15322092reponame:r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pauinstname:Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau)Inglésinfo:eu-repo/semantics/openAccessoai:iibsantpau.fundanetsuite.com:p69232026-06-14T12:41:47Z
dc.title.none.fl_str_mv Incidence of arrhythmias in a large cohort of patients with current implantable cardioverter-defibrillators in Spain: results from the UMBRELLA Registry
title Incidence of arrhythmias in a large cohort of patients with current implantable cardioverter-defibrillators in Spain: results from the UMBRELLA Registry
spellingShingle Incidence of arrhythmias in a large cohort of patients with current implantable cardioverter-defibrillators in Spain: results from the UMBRELLA Registry
Fontenla, A
Ventricular arrhythmias
Implantable cardioverter-defibrillator
Inappropriate shocks
Appropriate shocks
title_short Incidence of arrhythmias in a large cohort of patients with current implantable cardioverter-defibrillators in Spain: results from the UMBRELLA Registry
title_full Incidence of arrhythmias in a large cohort of patients with current implantable cardioverter-defibrillators in Spain: results from the UMBRELLA Registry
title_fullStr Incidence of arrhythmias in a large cohort of patients with current implantable cardioverter-defibrillators in Spain: results from the UMBRELLA Registry
title_full_unstemmed Incidence of arrhythmias in a large cohort of patients with current implantable cardioverter-defibrillators in Spain: results from the UMBRELLA Registry
title_sort Incidence of arrhythmias in a large cohort of patients with current implantable cardioverter-defibrillators in Spain: results from the UMBRELLA Registry
dc.creator.none.fl_str_mv Fontenla, A
Martinez-Ferrer, JB
Alzueta, J
Vinolas, X
Garcia-Alberola, A
Brugada, J
Peinado, R
Sancho-Tello, MJ
Cano, A
Fernandez-Lozano, I
author Fontenla, A
author_facet Fontenla, A
Martinez-Ferrer, JB
Alzueta, J
Vinolas, X
Garcia-Alberola, A
Brugada, J
Peinado, R
Sancho-Tello, MJ
Cano, A
Fernandez-Lozano, I
author_role author
author2 Martinez-Ferrer, JB
Alzueta, J
Vinolas, X
Garcia-Alberola, A
Brugada, J
Peinado, R
Sancho-Tello, MJ
Cano, A
Fernandez-Lozano, I
author2_role author
author
author
author
author
author
author
author
author
dc.subject.none.fl_str_mv Ventricular arrhythmias
Implantable cardioverter-defibrillator
Inappropriate shocks
Appropriate shocks
topic Ventricular arrhythmias
Implantable cardioverter-defibrillator
Inappropriate shocks
Appropriate shocks
description The benefit of implantable cardioverter-defibrillators (ICDs) in patients at risk of sudden death has been established in randomized clinical trials (RCTs) using the ICD models available at the time. However, observational large-scale data on the incidence of arrhythmias in up-to-date ICDs implanted according to the current guidelines are scarce. The aim was to assess the incidence of arrhythmias in a large, current ICD population based on a blinded peer review of the detected episodes. UMBRELLA is a multicentre, observational registry of ICD patients followed by remote monitoring. Stored episodes were classified by a blinded committee of experts. Subgroup analyses were based on clinical profiles established by previous pivotal RCTs of ICDs. Of 1514 enrolled patients, 605 (39.9%) patients had 5951 episodes after 26 +/- 17 months follow-up, being 3353 of them (56.3%) sustained ventricular arrhythmias (SVA), and 13.2% of SVA were self-terminated. Appropriate and inappropriate shocks occurred in 11.6 and 5% of patients, respectively. The 3 years cumulative incidence of SVA was 25% (95% CI: 21-28%) in primary prevention patients and 41% (95% CI: 36-47%) in secondary prevention patients (P < 0.001). Male gender, secondary prevention, and atrial fibrillation as basal rhythm were significantly related to a higher incidence of SVA. This real-world analysis suggests that modern ICD patients have a low rate of appropriate and inappropriate shocks. The risk of SVA in secondary prevention patients is less than what has been reported in RCTs.
publishDate 2016
dc.date.none.fl_str_mv 2016
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=6923
url https://iibsantpau.fundanetsuite.com/Publicaciones/ProdCientif/PublicacionFrw.aspx?id=6923
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv OXFORD UNIV PRESS
publisher.none.fl_str_mv OXFORD UNIV PRESS
dc.source.none.fl_str_mv EUROPACE
ISSN: 10995129
ISSNe: 15322092
reponame:r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
instname:Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau)
instname_str Institut d’Investigació Biomèdica Sant Pau (IIB Sant Pau)
reponame_str r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
collection r-IIB SANT PAU. Repositorio Institucional de Producción Científica del Instituto de Investigación Biomédica Sant Pau
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869416611663839232
score 15.81155