Dual-energy computed tomography (CT) versus cone-beam computed tomography (CT) in chronic thromboembolic pulmonary hypertension: diagnostic accuracy compared with digital subtraction angiography

AIM The aim of this study was to compare the diagnostic accuracy and interobserver agreement of dual-energy computed tomography pulmonary angiography (DECT-PA) and cone-beam computed tomography pulmonary angiography (CBCT-PA) for the evaluation of chronic thromboembolic pulmonary hypertension (CTEPH...

Descripción completa

Detalles Bibliográficos
Autores: Páez Carpio, Alfredo, Serrano, Elena, Domenech Ximenos, Blanca, Cornellas Escayola, Llúria, Barberà i Mir, Joan Albert, Vollmer Torrubiano, Ivan, Blanco Vich, Isabel, Gomez, F. M.
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2026
País:España
Institución:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
Repositorio:Recercat. Dipósit de la Recerca de Catalunya
OAI Identifier:oai:dnet:recercat____::6e73672f843928e7e1adc478571465c4
Acceso en línea:https://hdl.handle.net/2445/228798
Access Level:acceso abierto
Palabra clave:Hipertensió pulmonar
Edema pulmonar
Proves funcionals respiratòries
Pulmonary hypertension
Pulmonary edema
Respiratory function tests
id ES_ac482247f4615db5017c697dfd8c9939
oai_identifier_str oai:dnet:recercat____::6e73672f843928e7e1adc478571465c4
network_acronym_str ES
network_name_str España
repository_id_str
spelling Dual-energy computed tomography (CT) versus cone-beam computed tomography (CT) in chronic thromboembolic pulmonary hypertension: diagnostic accuracy compared with digital subtraction angiographyPáez Carpio, AlfredoSerrano, ElenaDomenech Ximenos, BlancaCornellas Escayola, LlúriaBarberà i Mir, Joan AlbertVollmer Torrubiano, IvanBlanco Vich, IsabelGomez, F. M.Hipertensió pulmonarEdema pulmonarProves funcionals respiratòriesPulmonary hypertensionPulmonary edemaRespiratory function testsAIM The aim of this study was to compare the diagnostic accuracy and interobserver agreement of dual-energy computed tomography pulmonary angiography (DECT-PA) and cone-beam computed tomography pulmonary angiography (CBCT-PA) for the evaluation of chronic thromboembolic pulmonary hypertension (CTEPH), using digital subtraction angiography pulmonary angiography (DSA-PA) as the reference standard. MATERIALS AND METHODS This retrospective study included 109 patients with confirmed CTEPH who underwent DECT-PA, CBCT-PA, and DSA-PA within a three-month interval between January 2017 and June 2022. Pulmonary arteries were evaluated at main, lobar, segmental, and subsegmental levels. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated. Interobserver agreement was assessed using Cohen's kappa (κ). RESULTS Overall diagnostic accuracy was comparable between DECT-PA (89.5%) and CBCT-PA (89.3%). DECT-PA demonstrated higher overall sensitivity (65.0% vs 53.5%, P = 0.019) but CBCT-PA achieved greater interobserver agreement (κ = 0.76 vs 0.74). Sensitivity declined in distal segments for both modalities, with CBCT-PA outperforming DECT-PA at the subsegmental level (51.9% vs 43.6%). Specificity remained high across modalities (>89%). The CBCT-PA showed superior agreement for lesion subtype classification, particularly for occlusions (κ = 0.839). CONCLUSION DECT-PA and CBCT-PA offer complementary strengths for the evaluation of CTEPH. DECT-PA provides high specificity for central and segmental lesions, supporting its role in initial assessment. CBCT-PA improves sensitivity and reproducibility in distal arteries, reinforcing its value for procedural planning and detailed vascular assessment. These findings support the use of DECT-PA as a first-line diagnostic tool and highlight the role of CBCT-PA as an adjunct in patients with distal or morphologically complex disease, potentially influencing diagnostic pathways and procedural planning in CTEPH.Elsevier2026202620262026info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion10 p.application/pdfhttps://hdl.handle.net/2445/228798Articles publicats en revistes (Medicina)reponame:Recercat. Dipósit de la Recerca de Catalunyainstname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)InglésReproducció del document publicat a: https://doi.org/10.1016/j.crad.2025.107152Clinical Radiology, 2026, vol. 92https://doi.org/10.1016/j.crad.2025.107152cc-by (c) Páez Carpio, Alfredo et al., 2026https://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:dnet:recercat____::6e73672f843928e7e1adc478571465c42026-05-29T05:05:01Z
dc.title.none.fl_str_mv Dual-energy computed tomography (CT) versus cone-beam computed tomography (CT) in chronic thromboembolic pulmonary hypertension: diagnostic accuracy compared with digital subtraction angiography
title Dual-energy computed tomography (CT) versus cone-beam computed tomography (CT) in chronic thromboembolic pulmonary hypertension: diagnostic accuracy compared with digital subtraction angiography
spellingShingle Dual-energy computed tomography (CT) versus cone-beam computed tomography (CT) in chronic thromboembolic pulmonary hypertension: diagnostic accuracy compared with digital subtraction angiography
Páez Carpio, Alfredo
Hipertensió pulmonar
Edema pulmonar
Proves funcionals respiratòries
Pulmonary hypertension
Pulmonary edema
Respiratory function tests
title_short Dual-energy computed tomography (CT) versus cone-beam computed tomography (CT) in chronic thromboembolic pulmonary hypertension: diagnostic accuracy compared with digital subtraction angiography
title_full Dual-energy computed tomography (CT) versus cone-beam computed tomography (CT) in chronic thromboembolic pulmonary hypertension: diagnostic accuracy compared with digital subtraction angiography
title_fullStr Dual-energy computed tomography (CT) versus cone-beam computed tomography (CT) in chronic thromboembolic pulmonary hypertension: diagnostic accuracy compared with digital subtraction angiography
title_full_unstemmed Dual-energy computed tomography (CT) versus cone-beam computed tomography (CT) in chronic thromboembolic pulmonary hypertension: diagnostic accuracy compared with digital subtraction angiography
title_sort Dual-energy computed tomography (CT) versus cone-beam computed tomography (CT) in chronic thromboembolic pulmonary hypertension: diagnostic accuracy compared with digital subtraction angiography
dc.creator.none.fl_str_mv Páez Carpio, Alfredo
Serrano, Elena
Domenech Ximenos, Blanca
Cornellas Escayola, Llúria
Barberà i Mir, Joan Albert
Vollmer Torrubiano, Ivan
Blanco Vich, Isabel
Gomez, F. M.
author Páez Carpio, Alfredo
author_facet Páez Carpio, Alfredo
Serrano, Elena
Domenech Ximenos, Blanca
Cornellas Escayola, Llúria
Barberà i Mir, Joan Albert
Vollmer Torrubiano, Ivan
Blanco Vich, Isabel
Gomez, F. M.
author_role author
author2 Serrano, Elena
Domenech Ximenos, Blanca
Cornellas Escayola, Llúria
Barberà i Mir, Joan Albert
Vollmer Torrubiano, Ivan
Blanco Vich, Isabel
Gomez, F. M.
author2_role author
author
author
author
author
author
author
dc.subject.none.fl_str_mv Hipertensió pulmonar
Edema pulmonar
Proves funcionals respiratòries
Pulmonary hypertension
Pulmonary edema
Respiratory function tests
topic Hipertensió pulmonar
Edema pulmonar
Proves funcionals respiratòries
Pulmonary hypertension
Pulmonary edema
Respiratory function tests
description AIM The aim of this study was to compare the diagnostic accuracy and interobserver agreement of dual-energy computed tomography pulmonary angiography (DECT-PA) and cone-beam computed tomography pulmonary angiography (CBCT-PA) for the evaluation of chronic thromboembolic pulmonary hypertension (CTEPH), using digital subtraction angiography pulmonary angiography (DSA-PA) as the reference standard. MATERIALS AND METHODS This retrospective study included 109 patients with confirmed CTEPH who underwent DECT-PA, CBCT-PA, and DSA-PA within a three-month interval between January 2017 and June 2022. Pulmonary arteries were evaluated at main, lobar, segmental, and subsegmental levels. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated. Interobserver agreement was assessed using Cohen's kappa (κ). RESULTS Overall diagnostic accuracy was comparable between DECT-PA (89.5%) and CBCT-PA (89.3%). DECT-PA demonstrated higher overall sensitivity (65.0% vs 53.5%, P = 0.019) but CBCT-PA achieved greater interobserver agreement (κ = 0.76 vs 0.74). Sensitivity declined in distal segments for both modalities, with CBCT-PA outperforming DECT-PA at the subsegmental level (51.9% vs 43.6%). Specificity remained high across modalities (>89%). The CBCT-PA showed superior agreement for lesion subtype classification, particularly for occlusions (κ = 0.839). CONCLUSION DECT-PA and CBCT-PA offer complementary strengths for the evaluation of CTEPH. DECT-PA provides high specificity for central and segmental lesions, supporting its role in initial assessment. CBCT-PA improves sensitivity and reproducibility in distal arteries, reinforcing its value for procedural planning and detailed vascular assessment. These findings support the use of DECT-PA as a first-line diagnostic tool and highlight the role of CBCT-PA as an adjunct in patients with distal or morphologically complex disease, potentially influencing diagnostic pathways and procedural planning in CTEPH.
publishDate 2026
dc.date.none.fl_str_mv 2026
2026
2026
2026
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://hdl.handle.net/2445/228798
url https://hdl.handle.net/2445/228798
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv Reproducció del document publicat a: https://doi.org/10.1016/j.crad.2025.107152
Clinical Radiology, 2026, vol. 92
https://doi.org/10.1016/j.crad.2025.107152
dc.rights.none.fl_str_mv cc-by (c) Páez Carpio, Alfredo et al., 2026
https://creativecommons.org/licenses/by/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv cc-by (c) Páez Carpio, Alfredo et al., 2026
https://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 10 p.
application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv Articles publicats en revistes (Medicina)
reponame:Recercat. Dipósit de la Recerca de Catalunya
instname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
instname_str Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
reponame_str Recercat. Dipósit de la Recerca de Catalunya
collection Recercat. Dipósit de la Recerca de Catalunya
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869416342023569408
score 15,811543