Techniques for On-Line Diagnosis of Stator Shorted Turns in Induction Motors

In low voltage induction motors, the first indication of a stator fault is the appearance of an inter-turn short circuit. For this reason, several attempts to diagnose reliably these short circuits have been made. Although considerable research has been carried out, the diagnosis of inter-turn short...

Descripción completa

Detalles Bibliográficos
Autores: Albizu Flórez, Igor, Zamora Belver, Inmaculada, Mazón Sainz-Maza, Angel Javier, Tapia Otaegui, María Aranzazu
Tipo de recurso: artículo
Fecha de publicación:2006
País:España
Institución:Universidad del País Vasco
Repositorio:Addi. Archivo Digital para la Docencia y la Investigación
OAI Identifier:oai:addi.ehu.eus:10810/4706
Acceso en línea:http://hdl.handle.net/10810/4706
Access Level:acceso abierto
Palabra clave:induction motors
online diagnosis
stator shorted turns
ELECTRICAL AND ELECTRONIC ENGINEERING
ENGINEERING, MECHANICAL
ENERGY ENGINEERING AND POWER TECHNOLOGY
id ES_abf2204b5cd032fbb0e46dfbfe1ab4a5
oai_identifier_str oai:addi.ehu.eus:10810/4706
network_acronym_str ES
network_name_str España
repository_id_str
spelling Techniques for On-Line Diagnosis of Stator Shorted Turns in Induction MotorsAlbizu Flórez, IgorZamora Belver, InmaculadaMazón Sainz-Maza, Angel JavierTapia Otaegui, María Aranzazuinduction motorsonline diagnosisstator shorted turnsELECTRICAL AND ELECTRONIC ENGINEERINGENGINEERING, MECHANICALENERGY ENGINEERING AND POWER TECHNOLOGYIn low voltage induction motors, the first indication of a stator fault is the appearance of an inter-turn short circuit. For this reason, several attempts to diagnose reliably these short circuits have been made. Although considerable research has been carried out, the diagnosis of inter-turn short circuits is not a mature technique yet. This paper presents and analyzes the on-line inter-turn short circuit diagnostic techniques developed so far for line-connected induction motors. By means of a comparative study, their advantages and drawbacks are highlighted.This work was supported by the Basque Government under the research project PRECORES (Ref. S-PE04UN22).Taylor & Francis201120112006info:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10810/4706reponame:Addi. Archivo Digital para la Docencia y la Investigacióninstname:Universidad del País VascoIngléshttp://www.tandfonline.com/doi/abs/10.1080/15325000691001359info:eu-repo/semantics/openAccess(c) 2007 Taylor & Francis Inc. This is an electronic version of an article published in Electric Power Components and Systems 34:97-114, 2006. Copyright © Taylor & Francis Inc. ISSN: 1532-5008 print/1532-5016 online. DOI: 10.1080/15325000691001359. Electric Power Components and Systems is available online at: http://www.tandfonline.com/doi/abs/10.1080/15325000691001359oai:addi.ehu.eus:10810/47062026-06-18T09:23:17Z
dc.title.none.fl_str_mv Techniques for On-Line Diagnosis of Stator Shorted Turns in Induction Motors
title Techniques for On-Line Diagnosis of Stator Shorted Turns in Induction Motors
spellingShingle Techniques for On-Line Diagnosis of Stator Shorted Turns in Induction Motors
Albizu Flórez, Igor
induction motors
online diagnosis
stator shorted turns
ELECTRICAL AND ELECTRONIC ENGINEERING
ENGINEERING, MECHANICAL
ENERGY ENGINEERING AND POWER TECHNOLOGY
title_short Techniques for On-Line Diagnosis of Stator Shorted Turns in Induction Motors
title_full Techniques for On-Line Diagnosis of Stator Shorted Turns in Induction Motors
title_fullStr Techniques for On-Line Diagnosis of Stator Shorted Turns in Induction Motors
title_full_unstemmed Techniques for On-Line Diagnosis of Stator Shorted Turns in Induction Motors
title_sort Techniques for On-Line Diagnosis of Stator Shorted Turns in Induction Motors
dc.creator.none.fl_str_mv Albizu Flórez, Igor
Zamora Belver, Inmaculada
Mazón Sainz-Maza, Angel Javier
Tapia Otaegui, María Aranzazu
author Albizu Flórez, Igor
author_facet Albizu Flórez, Igor
Zamora Belver, Inmaculada
Mazón Sainz-Maza, Angel Javier
Tapia Otaegui, María Aranzazu
author_role author
author2 Zamora Belver, Inmaculada
Mazón Sainz-Maza, Angel Javier
Tapia Otaegui, María Aranzazu
author2_role author
author
author
dc.subject.none.fl_str_mv induction motors
online diagnosis
stator shorted turns
ELECTRICAL AND ELECTRONIC ENGINEERING
ENGINEERING, MECHANICAL
ENERGY ENGINEERING AND POWER TECHNOLOGY
topic induction motors
online diagnosis
stator shorted turns
ELECTRICAL AND ELECTRONIC ENGINEERING
ENGINEERING, MECHANICAL
ENERGY ENGINEERING AND POWER TECHNOLOGY
description In low voltage induction motors, the first indication of a stator fault is the appearance of an inter-turn short circuit. For this reason, several attempts to diagnose reliably these short circuits have been made. Although considerable research has been carried out, the diagnosis of inter-turn short circuits is not a mature technique yet. This paper presents and analyzes the on-line inter-turn short circuit diagnostic techniques developed so far for line-connected induction motors. By means of a comparative study, their advantages and drawbacks are highlighted.
publishDate 2006
dc.date.none.fl_str_mv 2006
2011
2011
dc.type.none.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv http://hdl.handle.net/10810/4706
url http://hdl.handle.net/10810/4706
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv http://www.tandfonline.com/doi/abs/10.1080/15325000691001359
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Taylor & Francis
publisher.none.fl_str_mv Taylor & Francis
dc.source.none.fl_str_mv reponame:Addi. Archivo Digital para la Docencia y la Investigación
instname:Universidad del País Vasco
instname_str Universidad del País Vasco
reponame_str Addi. Archivo Digital para la Docencia y la Investigación
collection Addi. Archivo Digital para la Docencia y la Investigación
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869416313238061056
score 15,300719