Fully automatic 3D reconstruction of the placenta and its peripheral vasculature in intrauterine fetal MRI

Recent advances in fetal magnetic resonance imaging (MRI) open the door to improved detection and characterization of fetal and placental abnormalities. Since interpreting MRI data can be complex and ambiguous, there is a need for robust computational methods able to quantify placental anatomy (incl...

Descripción completa

Detalles Bibliográficos
Autores: Torrents Barrena, Jordina, Piella Fenoy, Gemma, Masoller, Narcís, Gratacós Solsona, Eduard, Eixarch, Elisenda, Ceresa, Mario, González Ballester, Miguel Ángel, 1973-
Tipo de recurso: artículo
Estado:Versión aceptada para publicación
Fecha de publicación:2019
País:España
Institución:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
Repositorio:Recercat. Dipósit de la Recerca de Catalunya
OAI Identifier:oai:recercat.cat:10230/37249
Acceso en línea:http://hdl.handle.net/10230/37249
Access Level:acceso abierto
Palabra clave:Fetal surgery
MRI
3D Super-resolution
Placenta and blood vessels segmentation
Gabor filter
Support vector machine
Corner detector
Descripción
Sumario:Recent advances in fetal magnetic resonance imaging (MRI) open the door to improved detection and characterization of fetal and placental abnormalities. Since interpreting MRI data can be complex and ambiguous, there is a need for robust computational methods able to quantify placental anatomy (including its vasculature) and function. In this work, we propose a novel fully-automated method to segment the placenta and its peripheral blood vessels from fetal MRI. First, a super-resolution reconstruction of the uterus is generated by combining axial, sagittal and coronal views. The placenta is then segmented using 3D Gabor filters, texture features and Support Vector Machines. A uterus edge-based instance selection is proposed to identify the support vectors defining the placenta boundary. Subsequently, peripheral blood vessels are extracted through a curvature-based corner detector. Our approach is validated on a rich set of 44 control and pathological cases: singleton and (normal / monochorionic) twin pregnancies between 25–37 weeks of gestation. Dice coefficients of 0.82  ±  0.02 and 0.81  ±  0.08 are achieved for placenta and its vasculature segmentation, respectively. A comparative analysis with state of the art convolutional neural networks (CNN), namely, 3D U-Net, V-Net, DeepMedic, Holistic3D Net, HighRes3D Net and Dense V-Net is also conducted for placenta localization, with our method outperforming all CNN approaches. Results suggest that our methodology can aid the diagnosis and surgical planning of severe fetal disorders.