Full Poincare Mueller polarimetry using a CCD camera

A new method is proposed to perform Mueller matrix polarimetry using a Full Poincare beam (i.e., a non-uniformly polarized beam presenting all polarization states across its section) as a parallel polarization state generator and a charge-coupled device (CCD) camera as a detector of the polarization...

Descripción completa

Detalles Bibliográficos
Autores: Suárez Bermejo, Juan Carlos, González de Sande, Juan Carlos, Piquero Sanz, Gemma María, Failla, Antonio Virgilio, Santarsiero, Massimo
Tipo de recurso: artículo
Fecha de publicación:2022
País:España
Institución:Universidad Complutense de Madrid (UCM)
Repositorio:Docta Complutense
Idioma:inglés
OAI Identifier:oai:docta.ucm.es:20.500.14352/72662
Acceso en línea:https://hdl.handle.net/20.500.14352/72662
Access Level:acceso abierto
Palabra clave:535
Calibration method
Refractive-index
Polarized beams
Mat
Óptica (Física)
2209.19 Óptica Física
id ES_aad5a4e56016a44958eda6b8d459e8da
oai_identifier_str oai:docta.ucm.es:20.500.14352/72662
network_acronym_str ES
network_name_str España
repository_id_str
spelling Full Poincare Mueller polarimetry using a CCD cameraSuárez Bermejo, Juan CarlosGonzález de Sande, Juan CarlosPiquero Sanz, Gemma MaríaFailla, Antonio VirgilioSantarsiero, Massimo535Calibration methodRefractive-indexPolarized beamsMatÓptica (Física)2209.19 Óptica FísicaA new method is proposed to perform Mueller matrix polarimetry using a Full Poincare beam (i.e., a non-uniformly polarized beam presenting all polarization states across its section) as a parallel polarization state generator and a charge-coupled device (CCD) camera as a detector of the polarization state analyzer. In this way, the polarization change is measured for all possible input states simultaneously. To obtain the Mueller matrix of the sample, the overdetermined system of equations that relates the input and output states of polarization is solved by means of the Moore-Penrose pseudo-inverse. Preliminary numerical simulations are performed to identify and exhaustively analyze the main sources of error. In order to test the method, experimental measurements are presented for several known samples, showing an excellent agreement between the experimentally obtained Mueller matrices and the theoretically expected ones.MDPIUniversidad Complutense de Madrid20222022-10-0120222022-10-01journal articlehttp://purl.org/coar/resource_type/c_6501info:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/20.500.14352/72662reponame:Docta Complutenseinstname:Universidad Complutense de Madrid (UCM)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Atribución 3.0 Españahttps://creativecommons.org/licenses/by/3.0/es/info:eu-repo/semantics/openAccessoai:docta.ucm.es:20.500.14352/726622026-06-02T12:44:21Z
dc.title.none.fl_str_mv Full Poincare Mueller polarimetry using a CCD camera
title Full Poincare Mueller polarimetry using a CCD camera
spellingShingle Full Poincare Mueller polarimetry using a CCD camera
Suárez Bermejo, Juan Carlos
535
Calibration method
Refractive-index
Polarized beams
Mat
Óptica (Física)
2209.19 Óptica Física
title_short Full Poincare Mueller polarimetry using a CCD camera
title_full Full Poincare Mueller polarimetry using a CCD camera
title_fullStr Full Poincare Mueller polarimetry using a CCD camera
title_full_unstemmed Full Poincare Mueller polarimetry using a CCD camera
title_sort Full Poincare Mueller polarimetry using a CCD camera
dc.creator.none.fl_str_mv Suárez Bermejo, Juan Carlos
González de Sande, Juan Carlos
Piquero Sanz, Gemma María
Failla, Antonio Virgilio
Santarsiero, Massimo
author Suárez Bermejo, Juan Carlos
author_facet Suárez Bermejo, Juan Carlos
González de Sande, Juan Carlos
Piquero Sanz, Gemma María
Failla, Antonio Virgilio
Santarsiero, Massimo
author_role author
author2 González de Sande, Juan Carlos
Piquero Sanz, Gemma María
Failla, Antonio Virgilio
Santarsiero, Massimo
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidad Complutense de Madrid
dc.subject.none.fl_str_mv 535
Calibration method
Refractive-index
Polarized beams
Mat
Óptica (Física)
2209.19 Óptica Física
topic 535
Calibration method
Refractive-index
Polarized beams
Mat
Óptica (Física)
2209.19 Óptica Física
description A new method is proposed to perform Mueller matrix polarimetry using a Full Poincare beam (i.e., a non-uniformly polarized beam presenting all polarization states across its section) as a parallel polarization state generator and a charge-coupled device (CCD) camera as a detector of the polarization state analyzer. In this way, the polarization change is measured for all possible input states simultaneously. To obtain the Mueller matrix of the sample, the overdetermined system of equations that relates the input and output states of polarization is solved by means of the Moore-Penrose pseudo-inverse. Preliminary numerical simulations are performed to identify and exhaustively analyze the main sources of error. In order to test the method, experimental measurements are presented for several known samples, showing an excellent agreement between the experimentally obtained Mueller matrices and the theoretically expected ones.
publishDate 2022
dc.date.none.fl_str_mv 2022
2022-10-01
2022
2022-10-01
dc.type.none.fl_str_mv journal article
http://purl.org/coar/resource_type/c_6501
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv https://hdl.handle.net/20.500.14352/72662
url https://hdl.handle.net/20.500.14352/72662
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
Atribución 3.0 España
https://creativecommons.org/licenses/by/3.0/es/
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
Atribución 3.0 España
https://creativecommons.org/licenses/by/3.0/es/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv MDPI
publisher.none.fl_str_mv MDPI
dc.source.none.fl_str_mv reponame:Docta Complutense
instname:Universidad Complutense de Madrid (UCM)
instname_str Universidad Complutense de Madrid (UCM)
reponame_str Docta Complutense
collection Docta Complutense
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869416216030871552
score 15,300724