Analysing local failure scenarios to assess the robustness of steel truss-type bridges

[EN] Many of the steel bridge collapses occur in truss-type bridges. This is, in fact, the focus of this study involving an assessment of the robustness of this type of structures based on an actual bridge that the authors had extensively monitored and controlled. Robustness was assessed by means of...

Descripción completa

Detalles Bibliográficos
Autores: Caredda, Giacomo|||0000-0002-6888-0409, Buitrago, Manuel|||0000-0002-5561-5104, Adam, Jose M|||0000-0002-9205-8458, Porcu, M. Cristina, Bertolesi, Elisa
Tipo de recurso: artículo
Fecha de publicación:2022
País:España
Institución:Universitat Politècnica de València (UPV)
Repositorio:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Idioma:inglés
OAI Identifier:oai:riunet.upv.es:10251/190017
Acceso en línea:https://riunet.upv.es/handle/10251/190017
Access Level:acceso abierto
Palabra clave:Alternative Load Paths
Computational Modelling
Recommendations
Robustness
Steel truss-types bridges
INGENIERIA DE LA CONSTRUCCION
09.- Desarrollar infraestructuras resilientes, promover la industrialización inclusiva y sostenible, y fomentar la innovación
Descripción
Sumario:[EN] Many of the steel bridge collapses occur in truss-type bridges. This is, in fact, the focus of this study involving an assessment of the robustness of this type of structures based on an actual bridge that the authors had extensively monitored and controlled. Robustness was assessed by means of computer simulations of various Damage Sce- narios (DSs) to analyse the structural bridge capacity to efficiently activate Alternative Load Paths (ALPs). The computational models have been previously validated with the results of load tests on the bridge and a laboratory test on a full-scale bridge span. The DSs have considered a series of non-simultaneous failures in different ele- ments. The results indicate that the structure is capable of not triggering a disproportionate collapse after each of the DSs with the help of the efficient activation of ALPs that required the contribution of other elements with extra-strength capacity as well as from the superstructure and the joints working under bending moments. The results were used as the basis for practical recommendations for: i) the design of new steel bridges and the retrofit of existing ones and ii) monitoring the structure for the optimal position of sensors to predict local failures that could spread to the rest of the bridge.