Plasma p-tau217 in Alzheimer's disease: Lumipulse and ALZpath SIMOA head-to-head comparison
Plasma phosphorylated-tau217 (p-tau217) has been shown to be one of the most accurate diagnostic markers for Alzheimer's disease. No studies have compared the clinical performance of p-tau217 as assessed by the fully automated Lumipulse and single molecule array (SIMOA) AlZpath p-tau217. Th...
| Autores: | , , , , , , , , , , , , , , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2025 |
| País: | España |
| Institución: | Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya) |
| Repositorio: | Recercat. Dipósit de la Recerca de Catalunya |
| OAI Identifier: | oai:dnet:recercat____::a9d9b6ac94515b2278d685612944c428 |
| Acceso en línea: | https://hdl.handle.net/10230/72956 http://dx.doi.org/10.1093/brain/awae368 |
| Access Level: | acceso abierto |
| Palabra clave: | ALZPath Alzheimer&apos s disease Lumipulse SIMOA p-tau217 Plasma markers |
| Sumario: | Plasma phosphorylated-tau217 (p-tau217) has been shown to be one of the most accurate diagnostic markers for Alzheimer's disease. No studies have compared the clinical performance of p-tau217 as assessed by the fully automated Lumipulse and single molecule array (SIMOA) AlZpath p-tau217. The study included 392 participants, 162 with Alzheimer's disease, 70 with other neurodegenerative diseases with CSF biomarkers and 160 healthy controls. Plasma p-tau217 levels were measured using the Lumipulse and ALZpath SIMOA assays. The ability of p-tau217 assessed by both techniques to discriminate Alzheimer's disease from other neurodegenerative diseases and controls was investigated using receiver operating characteristic analyses. The p-tau217 levels measured by the two techniques demonstrated a strong correlation, showing a consistent relationship with CSF p-tau181 levels. In head-to-head comparison, Lumipulse and SIMOA showed similar diagnostic accuracy for differentiating Alzheimer's disease from other neurodegenerative diseases [area under the curve (AUC) 0.952, 95% confidence interval (CI) 0.927-0.978 versus 0.955, 95% CI 0.928-0.982, respectively] and healthy controls (AUC 0.938, 95% CI 0.910-0.966 and 0.937, 95% CI 0.907-0.967 for both assays). This study demonstrated the high precision and diagnostic accuracy of p-tau217 for the clinical diagnosis of Alzheimer's disease using fully automated or semi-automated techniques. |
|---|