Development and experimental validation of a two-stage thermoelectric heat pump computational model for heating applications

The utilisation of thermoelectric technology as a heat pump in heating applications necessitates comprehensive investigation. The scalable nature of thermoelectric technology enables its operation at elevated temperatures without the requirement of refrigerants. In this work, an accurate computation...

Descripción completa

Detalles Bibliográficos
Autores: Erro Iturralde, Irantzu, Aranguren Garacochea, Patricia, Martínez Echeverri, Álvaro, Astrain Ulibarrena, David
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2024
País:España
Institución:Universidad Pública de Navarra
Repositorio:Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
OAI Identifier:oai:academica-e.unavarra.es:2454/50678
Acceso en línea:https://hdl.handle.net/2454/50678
Access Level:acceso abierto
Palabra clave:Thermoelectric heat pump
Multistage
Intermediate heat exchanger
Thermal resistance
Descripción
Sumario:The utilisation of thermoelectric technology as a heat pump in heating applications necessitates comprehensive investigation. The scalable nature of thermoelectric technology enables its operation at elevated temperatures without the requirement of refrigerants. In this work, an accurate computational model that can simulate one- and two-stage thermoelectric heat pumps is developed. This model uses the electric-thermal analogy and the finite difference method, including the thermoelectric effects, temperature dependent properties, thermal contact resistances and all heat exchangers, even the intermediate heat exchanger in the case of a two-stage configuration. Moreover, the model has been experimentally validated by built and tested prototypes, being the first time that a two-stage thermoelectric heat pump model is experimentally validated. The discrepancy between the simulated and experimental results is below the ± 10 % for , ± 8 % for generated heat and temperature lift in the airflow, and less than the ± 6 % for consumed power. Additonally, the model simulates real tendencies under different operating conditions, proving the reliability of the developed thermoelectric heat pump model. Finally, the model is used to optimise a thermoelectric system combining one- and two-stage thermoelectric heat pumps, and hybridising them with electric resistances. An airflow of 16.5 m3/h is heated from 25 °C to 160 °C, achieving a maximum of 1.21. Lastly, the importance of considering the thermal resistances of the heat exchangers is computationally modelled and demonstrated. Not taking them into account would overestimate the performance of the TEHP system by more than the 7 %.