Epileptogenic zone localization with (18)FDG PET using a new dynamic parametric analysis

Introduction: [18F]fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) is part of the regular preoperative work-up in medically refractory epilepsy. As a complement to visual evaluation of PET, statistical parametric maps can help in the detection of the epileptogenic zone (EZ). However,...

Descripción completa

Detalles Bibliográficos
Autores: Mayoral Peñalva, Maria, Niñerola Baizán, Aida, Marti Fuster, Berta, Donaire Pedraza, Antonio Jesús, Perissinotti, Andrés, Rumià, Jordi, Bargalló Alabart, Núria, Sala Llonch, Roser, Pavía Segura, Javier, Ros Puig, Domènec, Carreño, Mar, Pons Pons, Francisca, Setoain Perego, Xavier
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2019
País:España
Institución:Universidad de Barcelona
Repositorio:Dipòsit Digital de la UB
OAI Identifier:oai:diposit.ub.edu:2445/163163
Acceso en línea:https://hdl.handle.net/2445/163163
Access Level:acceso abierto
Palabra clave:Tomografia computada per emissió de fotó simple
Epilèpsia
Neurocirurgia
Single-photon emission computed tomography
Epilepsy
Neurosurgery
Descripción
Sumario:Introduction: [18F]fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) is part of the regular preoperative work-up in medically refractory epilepsy. As a complement to visual evaluation of PET, statistical parametric maps can help in the detection of the epileptogenic zone (EZ). However, software packages currently available are time-consuming and little intuitive for physicians. We develop a user-friendly software (referred as PET-analysis) for EZ localization in PET studies that allows dynamic real-time statistical parametric analysis. To evaluate its performance, the outcome of PET-analysis was compared with the results obtained by visual assessment and Statistical Parametric Mapping (SPM). Methods: Thirty patients with medically refractory epilepsy who underwent presurgical 18F-FDG PET with good post-operative outcomes were included. The 18F-FDG PET studies were evaluated by visual assessment, with SPM8 and PET-analysis. In SPM, parametric T-maps were thresholded at corrected p < 0.05 and cluster size k = 50 and at uncorrected p < 0.001 and k = 100 (the most used parameters in the literature). Since PET-analysis rapidly processes different threshold combinations, T-maps were thresholded with multiple p-value and different clusters sizes. The presurgical EZ identified by visual assessment, SPM and PET-analysis was compared to the confirmed EZ according to post-surgical follow-up. Results: PET-analysis obtained 66.7% (20/30) of correctly localizing studies, comparable to the 70.0% (21/30) achieved by visual assessment and significantly higher (p < 0.05) than that obtained with the SPM threshold p < 0.001/k = 100, of 36.7% (11/30). Only one study was positive, albeit non-localizing, with the SPM threshold corrected p < 0.05/k = 50. Concordance was substantial for PET-analysis (κ = 0.643) and visual interpretation (κ = 0.622), being fair for SPM (κ = 0.242). Conclusion: Compared to SPM with the fixed standard parameters, PET-analysis may be superior in EZ localization with its easy and rapid processing of different threshold combinations. The results of this initial proof-of-concept study validate the clinical use of PET-analysis as a robust objective complementary tool to visual assessment for EZ localization.