Enhanced dechlorination of 1,2-dichloropropane to propene in a bioelectrochemical system mediated by Dehalogenimonas

Bioelectrochemical systems (BES) are promising technologies to enhance the growth of organohalide-respiring bacteria and to treat chlorinated aliphatic hydrocarbons. In this study, two carbon-based cathodic electrode materials, a graphite brush and a carbon cloth, were used as hydrogen suppliers to...

Descripción completa

Detalles Bibliográficos
Autores: Fernandez Verdejo, David Juan|||0000-0002-3234-4006, Cortés Garmendia, M. Pilar|||0000-0002-5924-0653, Blánquez Cano, Paqui|||0000-0003-2443-9977, Marco Urrea, Ernest|||0000-0002-8033-6553, Guisasola, Albert|||0000-0002-3012-7964
Tipo de recurso: artículo
Fecha de publicación:2021
País:España
Institución:Universitat Autònoma de Barcelona
Repositorio:Dipòsit Digital de Documents de la UAB
Idioma:inglés
OAI Identifier:oai:ddd.uab.cat:273831
Acceso en línea:https://ddd.uab.cat/record/273831
https://dx.doi.org/urn:doi:10.1016/j.jhazmat.2021.126234
Access Level:acceso abierto
Palabra clave:1,2-dichloropropane
Bioelectrochemistry
Dehalogenimonas
Organohalide respiring bacteria
Remediation
Descripción
Sumario:Bioelectrochemical systems (BES) are promising technologies to enhance the growth of organohalide-respiring bacteria and to treat chlorinated aliphatic hydrocarbons. In this study, two carbon-based cathodic electrode materials, a graphite brush and a carbon cloth, were used as hydrogen suppliers to couple growth of Dehalogenimonas and dechlorination of 1,2-DCP to nontoxic propene in the cathode vessel. The BES with graphite brush electrode consumed ~4000 µM 1,2-DCP during 110 days and exhibited a degradation rate 5.6-fold higher than the maximum value obtained with the carbon cloth electrode, with a cathode potential set at -0.7 V. Quantitative PCR confirmed that Dehalogenimonas gene copies increased by two orders of magnitude in the graphite brush BES, with an average yield of 1.2·10 8±5·10 7 cells per µmol of 1,2-DCP degraded. The use of a pulsed voltage operation (cathode potential set at -0.6 V for 16 h and -1.1 V for 8 h) increased the coulombic efficiency and degradation of 1,2-DCP when compared with a continuous voltage operation of -1.1 V. Bacterial cell aggregates were observed in the surface of the graphite brush electrodes by electron scanning microscopy, suggesting biofilm formation. This study expands the range of chlorinated compounds degradable and organohalide-respiring bacteria capable of growing in BES.