Computational simulation of scleral buckling surgery for rhegmatogenous retinal detachment: on the effect of the band size on the myopization

A finite element model (FE) of the eye including cornea, sclera, crystalline lens, and ciliary body was created to analyze the influence of the silicone encircling bandwidth and the tightness degree on the myopia induced by scleral buckling (SB) procedure for rhegmatogenous retinal detachment. Intra...

Descripción completa

Detalles Bibliográficos
Autores: Lanchares, Elena, Buey, María A. del, Cristóbal, José A., Calvo, Begoña, Ascaso, Francisco J., Malvè, Mauro
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2016
País:España
Institución:Universidad Pública de Navarra
Repositorio:Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
OAI Identifier:oai:academica-e.unavarra.es:2454/30512
Acceso en línea:https://hdl.handle.net/2454/30512
Access Level:acceso abierto
Palabra clave:Scleral buckling surgery
Rhegmatogenous retinal detachment
Intraocular pressure
Myopia
Band size
id ES_97e9f514b0539c622cccd4919339ca0c
oai_identifier_str oai:academica-e.unavarra.es:2454/30512
network_acronym_str ES
network_name_str España
repository_id_str
spelling Computational simulation of scleral buckling surgery for rhegmatogenous retinal detachment: on the effect of the band size on the myopizationLanchares, ElenaBuey, María A. delCristóbal, José A.Calvo, BegoñaAscaso, Francisco J.Malvè, MauroScleral buckling surgeryRhegmatogenous retinal detachmentIntraocular pressureMyopiaBand sizeA finite element model (FE) of the eye including cornea, sclera, crystalline lens, and ciliary body was created to analyze the influence of the silicone encircling bandwidth and the tightness degree on the myopia induced by scleral buckling (SB) procedure for rhegmatogenous retinal detachment. Intraocular pressure (IOP) was applied to the reference geometry of the FE model and then SB surgery was simulated with encircling bandwidths of 1, 2, and 2.5 mm. Different levels of tightening and three values of IOP were applied.The anterior segment resulted as unaffected by the surgery. The highest value of Cauchy stress appeared in the surroundings of the implant, whereas no increment of stress was observed either in anterior segment or in the optic nerve head. The initial IOP did not appear to play any role in the induced myopia.The wider the band, the greater the induced myopia: 0.44, 0.88, and 1.07 diopters (D) for the 1, 2, and 2.5mm bandwidth, respectively.Therefore, patients become more myopic with a wider encircling element. The proposed simulations allow determining the effect of the bandwidth or the tightness degree on the axial lengthening, thus predicting the myopic increment caused by the encircling surgery.The authors wish to acknowledge the research support by the Spanish Ministry of Education and Science Research Project DPI2014-54981R, the CIBER initiative, Instituto de Salud Carlos III (ISCIII) Platformfor Biological Tissue Characterization of the Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBERBBN), and the Department of Industry and Innovation (Government of Aragón) through the research group Grant T88 (Fondo Social Europeo).HindawiIngeniería Mecánica, Energética y de MaterialesMekanika, Energetika eta Materialen Ingeniaritza2016info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://hdl.handle.net/2454/30512reponame:Academica-e. Repositorio Institucional de la Universidad Pública de Navarrainstname:Universidad Pública de NavarraInglésinfo:eu-repo/grantAgreement/MINECO//DPI2014-54981-R© 2016 Elena Lanchares et al.This is an open access article distributed under theCreative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.https://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:academica-e.unavarra.es:2454/305122026-06-17T12:41:47Z
dc.title.none.fl_str_mv Computational simulation of scleral buckling surgery for rhegmatogenous retinal detachment: on the effect of the band size on the myopization
title Computational simulation of scleral buckling surgery for rhegmatogenous retinal detachment: on the effect of the band size on the myopization
spellingShingle Computational simulation of scleral buckling surgery for rhegmatogenous retinal detachment: on the effect of the band size on the myopization
Lanchares, Elena
Scleral buckling surgery
Rhegmatogenous retinal detachment
Intraocular pressure
Myopia
Band size
title_short Computational simulation of scleral buckling surgery for rhegmatogenous retinal detachment: on the effect of the band size on the myopization
title_full Computational simulation of scleral buckling surgery for rhegmatogenous retinal detachment: on the effect of the band size on the myopization
title_fullStr Computational simulation of scleral buckling surgery for rhegmatogenous retinal detachment: on the effect of the band size on the myopization
title_full_unstemmed Computational simulation of scleral buckling surgery for rhegmatogenous retinal detachment: on the effect of the band size on the myopization
title_sort Computational simulation of scleral buckling surgery for rhegmatogenous retinal detachment: on the effect of the band size on the myopization
dc.creator.none.fl_str_mv Lanchares, Elena
Buey, María A. del
Cristóbal, José A.
Calvo, Begoña
Ascaso, Francisco J.
Malvè, Mauro
author Lanchares, Elena
author_facet Lanchares, Elena
Buey, María A. del
Cristóbal, José A.
Calvo, Begoña
Ascaso, Francisco J.
Malvè, Mauro
author_role author
author2 Buey, María A. del
Cristóbal, José A.
Calvo, Begoña
Ascaso, Francisco J.
Malvè, Mauro
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Ingeniería Mecánica, Energética y de Materiales
Mekanika, Energetika eta Materialen Ingeniaritza
dc.subject.none.fl_str_mv Scleral buckling surgery
Rhegmatogenous retinal detachment
Intraocular pressure
Myopia
Band size
topic Scleral buckling surgery
Rhegmatogenous retinal detachment
Intraocular pressure
Myopia
Band size
description A finite element model (FE) of the eye including cornea, sclera, crystalline lens, and ciliary body was created to analyze the influence of the silicone encircling bandwidth and the tightness degree on the myopia induced by scleral buckling (SB) procedure for rhegmatogenous retinal detachment. Intraocular pressure (IOP) was applied to the reference geometry of the FE model and then SB surgery was simulated with encircling bandwidths of 1, 2, and 2.5 mm. Different levels of tightening and three values of IOP were applied.The anterior segment resulted as unaffected by the surgery. The highest value of Cauchy stress appeared in the surroundings of the implant, whereas no increment of stress was observed either in anterior segment or in the optic nerve head. The initial IOP did not appear to play any role in the induced myopia.The wider the band, the greater the induced myopia: 0.44, 0.88, and 1.07 diopters (D) for the 1, 2, and 2.5mm bandwidth, respectively.Therefore, patients become more myopic with a wider encircling element. The proposed simulations allow determining the effect of the bandwidth or the tightness degree on the axial lengthening, thus predicting the myopic increment caused by the encircling surgery.
publishDate 2016
dc.date.none.fl_str_mv 2016
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://hdl.handle.net/2454/30512
url https://hdl.handle.net/2454/30512
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv info:eu-repo/grantAgreement/MINECO//DPI2014-54981-R
dc.rights.none.fl_str_mv https://creativecommons.org/licenses/by/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Hindawi
publisher.none.fl_str_mv Hindawi
dc.source.none.fl_str_mv reponame:Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
instname:Universidad Pública de Navarra
instname_str Universidad Pública de Navarra
reponame_str Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
collection Academica-e. Repositorio Institucional de la Universidad Pública de Navarra
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869414118438469632
score 15.81155