Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems
[EN] In order to mitigate climate change, reductions of energy consumption are required on heating systems for residential and non-residential buildings. Despite radiant floor heating systems are being widely used due to their high thermal efficiency and comfort, further improvements are necessary t...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2021 |
| País: | España |
| Institución: | Universidad del País Vasco |
| Repositorio: | Addi. Archivo Digital para la Docencia y la Investigación |
| OAI Identifier: | oai:addi.ehu.eus:10810/52551 |
| Acceso en línea: | http://hdl.handle.net/10810/52551 https://doi.org/10.1016/j.jobe.2021.102408 |
| Access Level: | acceso abierto |
| Palabra clave: | lime mud paper sludge radiant floor cement mortar |
| id |
ES_966eaa14c4b85ef53e2b2e7ca6ee85e1 |
|---|---|
| oai_identifier_str |
oai:addi.ehu.eus:10810/52551 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systemsBorinaga Treviño, RoqueCuadrado Rojo, JesúsCanales Abaitua, JavierRojí Chandro, Eduardolime mudpaper sludgeradiant floorcementmortar[EN] In order to mitigate climate change, reductions of energy consumption are required on heating systems for residential and non-residential buildings. Despite radiant floor heating systems are being widely used due to their high thermal efficiency and comfort, further improvements are necessary to reduce the carbon footprint of the mortars used. This paper studies the use of lime mud, a by-product of the paper industry, as a partial replacement of cement to reduce the environmental impact of the resulting mortar. For that purpose, a reference cement mortar is compared to mortars with 10%, 20%, 30% and 40% of cement replacement by weight. Physical, thermal and mechanical properties showed that up to 20% of cement could be replaced by lime mud while maintaining thermal properties of the mortar. Despite the reduction of the mechanical resistance, mortars with up to 20% of cement replacement fulfilled the requirements of EN 1264-4:2010 standard. Finally, tests on laboratory-made radiant floor heating slabs proved that slabs with reference mortar had a similar stationary behaviour to that of the slabs with mortar containing 20% of lime mud, but the latter reach stationary faster due to the lower thermal inertia of its mortar.This work was supported by the the European Horizon 2020 Joint Technology Initiative Shift2Rail, IN2TRACK2 project [grant number 826255]; Basque Government (Elkartek 2019, GOLIAT2 project) [grant number KK-2019/00023]; Basque Government [grant numbers IT919-16, IT1314-19]. We also want to show gratitude to SMURFIT KAPPA NERVION for donating the lime mud used.Elsevier Ltd.European Commission202120212021info:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10810/52551https://doi.org/10.1016/j.jobe.2021.102408reponame:Addi. Archivo Digital para la Docencia y la Investigacióninstname:Universidad del País VascoInglésinfo:eu-repo/grantAgreement/EC/H2020/826255https://www.sciencedirect.com/science/article/pii/S2352710221002667#sec5info:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/3.0/es/© 2021 The Authors. This article is available under the Creative Commons CC-BY-NC-ND license and permits non-commercial use of the work as published, without adaptation or alteration provided the work is fully attributed.Atribución-NoComercial-SinDerivadas 3.0 Españaoai:addi.ehu.eus:10810/525512026-06-18T09:23:17Z |
| dc.title.none.fl_str_mv |
Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems |
| title |
Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems |
| spellingShingle |
Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems Borinaga Treviño, Roque lime mud paper sludge radiant floor cement mortar |
| title_short |
Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems |
| title_full |
Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems |
| title_fullStr |
Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems |
| title_full_unstemmed |
Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems |
| title_sort |
Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems |
| dc.creator.none.fl_str_mv |
Borinaga Treviño, Roque Cuadrado Rojo, Jesús Canales Abaitua, Javier Rojí Chandro, Eduardo |
| author |
Borinaga Treviño, Roque |
| author_facet |
Borinaga Treviño, Roque Cuadrado Rojo, Jesús Canales Abaitua, Javier Rojí Chandro, Eduardo |
| author_role |
author |
| author2 |
Cuadrado Rojo, Jesús Canales Abaitua, Javier Rojí Chandro, Eduardo |
| author2_role |
author author author |
| dc.contributor.none.fl_str_mv |
European Commission |
| dc.subject.none.fl_str_mv |
lime mud paper sludge radiant floor cement mortar |
| topic |
lime mud paper sludge radiant floor cement mortar |
| description |
[EN] In order to mitigate climate change, reductions of energy consumption are required on heating systems for residential and non-residential buildings. Despite radiant floor heating systems are being widely used due to their high thermal efficiency and comfort, further improvements are necessary to reduce the carbon footprint of the mortars used. This paper studies the use of lime mud, a by-product of the paper industry, as a partial replacement of cement to reduce the environmental impact of the resulting mortar. For that purpose, a reference cement mortar is compared to mortars with 10%, 20%, 30% and 40% of cement replacement by weight. Physical, thermal and mechanical properties showed that up to 20% of cement could be replaced by lime mud while maintaining thermal properties of the mortar. Despite the reduction of the mechanical resistance, mortars with up to 20% of cement replacement fulfilled the requirements of EN 1264-4:2010 standard. Finally, tests on laboratory-made radiant floor heating slabs proved that slabs with reference mortar had a similar stationary behaviour to that of the slabs with mortar containing 20% of lime mud, but the latter reach stationary faster due to the lower thermal inertia of its mortar. |
| publishDate |
2021 |
| dc.date.none.fl_str_mv |
2021 2021 2021 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/10810/52551 https://doi.org/10.1016/j.jobe.2021.102408 |
| url |
http://hdl.handle.net/10810/52551 https://doi.org/10.1016/j.jobe.2021.102408 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
info:eu-repo/grantAgreement/EC/H2020/826255 https://www.sciencedirect.com/science/article/pii/S2352710221002667#sec5 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess http://creativecommons.org/licenses/by-nc-nd/3.0/es/ Atribución-NoComercial-SinDerivadas 3.0 España |
| eu_rights_str_mv |
openAccess |
| rights_invalid_str_mv |
http://creativecommons.org/licenses/by-nc-nd/3.0/es/ Atribución-NoComercial-SinDerivadas 3.0 España |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Elsevier Ltd. |
| publisher.none.fl_str_mv |
Elsevier Ltd. |
| dc.source.none.fl_str_mv |
reponame:Addi. Archivo Digital para la Docencia y la Investigación instname:Universidad del País Vasco |
| instname_str |
Universidad del País Vasco |
| reponame_str |
Addi. Archivo Digital para la Docencia y la Investigación |
| collection |
Addi. Archivo Digital para la Docencia y la Investigación |
| repository.name.fl_str_mv |
|