Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems

[EN] In order to mitigate climate change, reductions of energy consumption are required on heating systems for residential and non-residential buildings. Despite radiant floor heating systems are being widely used due to their high thermal efficiency and comfort, further improvements are necessary t...

Descripción completa

Detalles Bibliográficos
Autores: Borinaga Treviño, Roque, Cuadrado Rojo, Jesús, Canales Abaitua, Javier, Rojí Chandro, Eduardo
Tipo de recurso: artículo
Fecha de publicación:2021
País:España
Institución:Universidad del País Vasco
Repositorio:Addi. Archivo Digital para la Docencia y la Investigación
OAI Identifier:oai:addi.ehu.eus:10810/52551
Acceso en línea:http://hdl.handle.net/10810/52551
https://doi.org/10.1016/j.jobe.2021.102408
Access Level:acceso abierto
Palabra clave:lime mud
paper sludge
radiant floor
cement
mortar
id ES_966eaa14c4b85ef53e2b2e7ca6ee85e1
oai_identifier_str oai:addi.ehu.eus:10810/52551
network_acronym_str ES
network_name_str España
repository_id_str
spelling Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systemsBorinaga Treviño, RoqueCuadrado Rojo, JesúsCanales Abaitua, JavierRojí Chandro, Eduardolime mudpaper sludgeradiant floorcementmortar[EN] In order to mitigate climate change, reductions of energy consumption are required on heating systems for residential and non-residential buildings. Despite radiant floor heating systems are being widely used due to their high thermal efficiency and comfort, further improvements are necessary to reduce the carbon footprint of the mortars used. This paper studies the use of lime mud, a by-product of the paper industry, as a partial replacement of cement to reduce the environmental impact of the resulting mortar. For that purpose, a reference cement mortar is compared to mortars with 10%, 20%, 30% and 40% of cement replacement by weight. Physical, thermal and mechanical properties showed that up to 20% of cement could be replaced by lime mud while maintaining thermal properties of the mortar. Despite the reduction of the mechanical resistance, mortars with up to 20% of cement replacement fulfilled the requirements of EN 1264-4:2010 standard. Finally, tests on laboratory-made radiant floor heating slabs proved that slabs with reference mortar had a similar stationary behaviour to that of the slabs with mortar containing 20% of lime mud, but the latter reach stationary faster due to the lower thermal inertia of its mortar.This work was supported by the the European Horizon 2020 Joint Technology Initiative Shift2Rail, IN2TRACK2 project [grant number 826255]; Basque Government (Elkartek 2019, GOLIAT2 project) [grant number KK-2019/00023]; Basque Government [grant numbers IT919-16, IT1314-19]. We also want to show gratitude to SMURFIT KAPPA NERVION for donating the lime mud used.Elsevier Ltd.European Commission202120212021info:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10810/52551https://doi.org/10.1016/j.jobe.2021.102408reponame:Addi. Archivo Digital para la Docencia y la Investigacióninstname:Universidad del País VascoInglésinfo:eu-repo/grantAgreement/EC/H2020/826255https://www.sciencedirect.com/science/article/pii/S2352710221002667#sec5info:eu-repo/semantics/openAccesshttp://creativecommons.org/licenses/by-nc-nd/3.0/es/© 2021 The Authors. This article is available under the Creative Commons CC-BY-NC-ND license and permits non-commercial use of the work as published, without adaptation or alteration provided the work is fully attributed.Atribución-NoComercial-SinDerivadas 3.0 Españaoai:addi.ehu.eus:10810/525512026-06-18T09:23:17Z
dc.title.none.fl_str_mv Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems
title Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems
spellingShingle Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems
Borinaga Treviño, Roque
lime mud
paper sludge
radiant floor
cement
mortar
title_short Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems
title_full Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems
title_fullStr Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems
title_full_unstemmed Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems
title_sort Lime mud waste from the paper industry as a partial replacement of cement in mortars used on radiant floor heating systems
dc.creator.none.fl_str_mv Borinaga Treviño, Roque
Cuadrado Rojo, Jesús
Canales Abaitua, Javier
Rojí Chandro, Eduardo
author Borinaga Treviño, Roque
author_facet Borinaga Treviño, Roque
Cuadrado Rojo, Jesús
Canales Abaitua, Javier
Rojí Chandro, Eduardo
author_role author
author2 Cuadrado Rojo, Jesús
Canales Abaitua, Javier
Rojí Chandro, Eduardo
author2_role author
author
author
dc.contributor.none.fl_str_mv European Commission
dc.subject.none.fl_str_mv lime mud
paper sludge
radiant floor
cement
mortar
topic lime mud
paper sludge
radiant floor
cement
mortar
description [EN] In order to mitigate climate change, reductions of energy consumption are required on heating systems for residential and non-residential buildings. Despite radiant floor heating systems are being widely used due to their high thermal efficiency and comfort, further improvements are necessary to reduce the carbon footprint of the mortars used. This paper studies the use of lime mud, a by-product of the paper industry, as a partial replacement of cement to reduce the environmental impact of the resulting mortar. For that purpose, a reference cement mortar is compared to mortars with 10%, 20%, 30% and 40% of cement replacement by weight. Physical, thermal and mechanical properties showed that up to 20% of cement could be replaced by lime mud while maintaining thermal properties of the mortar. Despite the reduction of the mechanical resistance, mortars with up to 20% of cement replacement fulfilled the requirements of EN 1264-4:2010 standard. Finally, tests on laboratory-made radiant floor heating slabs proved that slabs with reference mortar had a similar stationary behaviour to that of the slabs with mortar containing 20% of lime mud, but the latter reach stationary faster due to the lower thermal inertia of its mortar.
publishDate 2021
dc.date.none.fl_str_mv 2021
2021
2021
dc.type.none.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv http://hdl.handle.net/10810/52551
https://doi.org/10.1016/j.jobe.2021.102408
url http://hdl.handle.net/10810/52551
https://doi.org/10.1016/j.jobe.2021.102408
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv info:eu-repo/grantAgreement/EC/H2020/826255
https://www.sciencedirect.com/science/article/pii/S2352710221002667#sec5
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
http://creativecommons.org/licenses/by-nc-nd/3.0/es/
Atribución-NoComercial-SinDerivadas 3.0 España
eu_rights_str_mv openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by-nc-nd/3.0/es/
Atribución-NoComercial-SinDerivadas 3.0 España
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier Ltd.
publisher.none.fl_str_mv Elsevier Ltd.
dc.source.none.fl_str_mv reponame:Addi. Archivo Digital para la Docencia y la Investigación
instname:Universidad del País Vasco
instname_str Universidad del País Vasco
reponame_str Addi. Archivo Digital para la Docencia y la Investigación
collection Addi. Archivo Digital para la Docencia y la Investigación
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869413949420601344
score 15,300724