Comportamiento a flexión y cortante de un tablero continuo de vigas pretensadas con tendones de polímeros reforzados con fibras (FRP)

(English) The durability of reinforced concrete structures is mainly compromised by steel corrosion, which generates high maintenance costs and reduces structural safety. Fiber-reinforced polymers (FRP) represent an alternative of great interest, as they provide high specific strength and are not su...

Descripción completa

Detalles Bibliográficos
Autor: Ramírez Pérez, Alexis Johariv
Tipo de recurso: tesis doctoral
Fecha de publicación:2026
País:España
Institución:Universitat Politècnica de Catalunya (UPC)
Repositorio:UPCommons. Portal del coneixement obert de la UPC
Idioma:español
OAI Identifier:oai:upcommons.upc.edu:2117/451551
Acceso en línea:https://hdl.handle.net/2117/451551
https://dx.doi.org/10.5821/dissertation-2117-451551
Access Level:acceso abierto
Palabra clave:Hormigón pretensado
Polímeros reforzados con fibras (FRP)
Cables compuestos de fibra de carbono (CFCC)
Vigas continuas
Flexión
Cortante
Interfaz viga–losa
Armadura activa de FRP
Armadura transversal de FRP
Ensayos experimentales
Modelización numérica
Durabilidad estructural
Anclajes de FRP
Longitud de transferencia
Redistribución de esfuerzos
Puentes prefabricados
Comparación experimental–numérica
624 - Enginyeria civil i de la construcció en general
Àrees temàtiques de la UPC::Enginyeria civil
Descripción
Sumario:(English) The durability of reinforced concrete structures is mainly compromised by steel corrosion, which generates high maintenance costs and reduces structural safety. Fiber-reinforced polymers (FRP) represent an alternative of great interest, as they provide high specific strength and are not susceptible to corrosion. However, their application as active reinforcement in continuous prestressed members is still very limited, due to the scarce experimental research on their structural performance and the absence of specific design guidelines. The main objective of this dissertation is to analyze the flexural and shear behavior of a two-span continuous bridge at 1/3 scale, built with precast prestressed girders and a cast in situ reinforced concrete slab, using carbon carbon fiber composite cables “CFCC” tendons as active reinforcement. The research was organized into three phases: (1) characterization of carbon fiber (CFRP) bars, glass fiber (GFRP) bars, and CFCC tendons, with the latter selected for prestressing due to their suitability; (2) a flexural test on span 1, with a concentrated load applied at midspan, to study the global flexural behavior at the serviceability and ultimate limit states; and (3) a shear test on span 2, with a concentrated load applied 1.6 m from the end support, to evaluate shear strength, effectiveness of GFRP stirrups, and the influence of CFCC prestressing. The results were compared with numerical simulations using the CONS program and with the CCCM analytical model adapted to FRP tendons. The experimental tests showed that CFCC tendons reached 62–76% of their ultimate strength without anchorage slip in the flexural test, confirming their reliability as active reinforcement. Failure was governed by shear-off at the girder–slab interface. In shear, failure occurred after a characteristic diagonal cracking pattern and progressive redistribution of stresses between spans, while shear-off failure was avoided through a reinforcement added after the flexural test. The overall contribution of this dissertation lies in providing the first comprehensive experimental, analytical, and numerical evidence on a continuous bridge prestressed with CFCC tendons. The findings strengthen confidence in the use of FRP in concrete structures, and open new research avenues aimed at optimizing transverse reinforcement and moving towards the codification of this technology.