Metabolic Control of the FreeStyle Libre System in the Pediatric Population with Type 1 Diabetes Dependent on Sensor Adherence.

To evaluate the relationship between daily sensor scan rates and changes in HbA1c and hypoglycemia in children. We enrolled 145 paediatric T1D patients into a prospective, interventional study of the impact of the FreeStyle Libre 1 system on measures of glycemic control. HbA1c was higher at lower sc...

ver descrição completa

Detalhes bibliográficos
Autores: Leiva-Gea, Isabel, Martos-Lirio, Maria F, Gómez-Perea, Ana, Ariza-Jiménez, Ana-Belen, Tapia-Ceballos, Leopoldo, Jiménez-Hinojosa, Jose Manuel, Lopez-Siguero, Juan Pedro
Tipo de documento: artigo
Data de publicação:2022
País:España
Recursos:Instituto de Salud Carlos III (ISCIII)
Repositório:Repisalud
Idioma:inglês
OAI Identifier:oai:repisalud.isciii.es:20.500.12105/18575
Acesso em linha:http://hdl.handle.net/20.500.12105/18575
Access Level:Acceso aberto
Palavra-chave:flash glucose monitoring
hypoglycemia
sensor scanning
Descrição
Resumo:To evaluate the relationship between daily sensor scan rates and changes in HbA1c and hypoglycemia in children. We enrolled 145 paediatric T1D patients into a prospective, interventional study of the impact of the FreeStyle Libre 1 system on measures of glycemic control. HbA1c was higher at lower scan rates, and decreased as the scan rate increased to 15-20 scans, after which it rose at higher scan rates. An analysis of the change in hypoglycemia, based on the number of daily sensor scans, showed there was a significant correlation between daily scan rates and hypoglycemia. Subjects with higher daily scan rates reduced all levels of hypoglycaemia. HbA1c is higher at lower scan rates, and decreases as scan rate increases. Reductions in hypoglycemia were evident in subjects with higher daily scan rates.