Development and validation of a capillary zone electrophoresis method for the quantitative determination of anthocyanins in wine

A capillary zone electrophoresis (CZE) method is proposed for the quantitative determination of anthocyanins in wine as an alternative to high-performance liquid chromatography. The CZE separation was carried out using a 46 cm (effective length)×75 μm I.D. fused-silica capillary at 10°C and a 50 mM...

Descripción completa

Detalles Bibliográficos
Autores: Sáenz-López, R., Fernández-Zurbano, P. [0000-0002-4516-9534], Tena, M.T. [0000-0002-8841-2653]
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2003
País:España
Institución:Universidad de La Rioja (UR)
Repositorio:RIUR. Repositorio Institucional de la Universidad de La Rioja
OAI Identifier:oai:portal.dialnet.es:doc/5bbc69bbb750603269e82076
Acceso en línea:https://investigacion.unirioja.es/documentos/5bbc69bbb750603269e82076
Access Level:acceso abierto
Palabra clave:Anthocyanins
Food analysis
Glucosides
Wine
Descripción
Sumario:A capillary zone electrophoresis (CZE) method is proposed for the quantitative determination of anthocyanins in wine as an alternative to high-performance liquid chromatography. The CZE separation was carried out using a 46 cm (effective length)×75 μm I.D. fused-silica capillary at 10°C and a 50 mM sodium tetraborate buffer at pH 8.4 with 15% of methanol as modifier. A voltage of 25 kV and a hydrodynamic injection of 300 mbar s were used. The electropherograms were recorded at 599 nm. It was found that SO2 (antibacterial and antioxidant agent added to wine during its production) increased the absorbance of anthocyanins at 599 nm in a basic medium. Therefore, a concentration of 250 mg/l of SO2 was added to the samples and the calibration solution before the analysis in order to avoid errors by this matrix effect. The analytical response was linear (R=0.998) between 10 and 700 μg/ml of malvidin-3-O-glucoside. The limit of detection and the reproducibility (as a relative standard deviation, n=11) were 1 μg/ml and 1.5%, respectively. Finally, the CZE method was validated by the analysis of synthetic wine samples (errors less than 8%) and by the comparison of the results obtained in the analysis of different monovarietal wines by CZE with those obtained by the standard HPLC method. In this comparison, a good correlation (R=0.998) with a slope of 1.005±0.044 and an intercept of -0.752±6.690 was obtained for malvidin-3-O-glucoside. © 2002 Elsevier Science B.V. All rights reserved.