Design of zero reference codes by means of a global optimization method
The grating measurement systems can be used for displacement and angle measurements. They require of zero reference codes to obtain zero reference signals and absolute measures. The zero reference signals are obtained from the autocorrelation of two identical zero reference codes. The design of code...
| Authors: | , , |
|---|---|
| Format: | article |
| Publication Date: | 2005 |
| Country: | España |
| Institution: | Universidad Complutense de Madrid (UCM) |
| Repository: | Docta Complutense |
| Language: | English |
| OAI Identifier: | oai:docta.ucm.es:20.500.14352/51199 |
| Online Access: | https://hdl.handle.net/20.500.14352/51199 |
| Access Level: | Open access |
| Keyword: | 535 Accurate Alignment Bar Codes Systems Óptica (Física) 2209.19 Óptica Física |
| id |
ES_8d90b80fd95992e65f12e3dbc61e6c07 |
|---|---|
| oai_identifier_str |
oai:docta.ucm.es:20.500.14352/51199 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Design of zero reference codes by means of a global optimization methodSaez Landete, JoséAlonso Fernández, JoséBernabeu Martínez, Eusebio535Accurate AlignmentBar CodesSystemsÓptica (Física)2209.19 Óptica FísicaThe grating measurement systems can be used for displacement and angle measurements. They require of zero reference codes to obtain zero reference signals and absolute measures. The zero reference signals are obtained from the autocorrelation of two identical zero reference codes. The design of codes which generate optimum signals is rather complex, especially for larges codes. In this paper we present a global optimization method, a DIRECT algorithm for the design of zero reference codes. This method proves to be a powerful tool for solving this inverse problem.The Optical Society Of AmericaUniversidad Complutense de Madrid20052005-01-1020052005-01-10journal articlehttp://purl.org/coar/resource_type/c_6501info:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/20.500.14352/51199reponame:Docta Complutenseinstname:Universidad Complutense de Madrid (UCM)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2info:eu-repo/semantics/openAccessoai:docta.ucm.es:20.500.14352/511992026-06-02T12:44:21Z |
| dc.title.none.fl_str_mv |
Design of zero reference codes by means of a global optimization method |
| title |
Design of zero reference codes by means of a global optimization method |
| spellingShingle |
Design of zero reference codes by means of a global optimization method Saez Landete, José 535 Accurate Alignment Bar Codes Systems Óptica (Física) 2209.19 Óptica Física |
| title_short |
Design of zero reference codes by means of a global optimization method |
| title_full |
Design of zero reference codes by means of a global optimization method |
| title_fullStr |
Design of zero reference codes by means of a global optimization method |
| title_full_unstemmed |
Design of zero reference codes by means of a global optimization method |
| title_sort |
Design of zero reference codes by means of a global optimization method |
| dc.creator.none.fl_str_mv |
Saez Landete, José Alonso Fernández, José Bernabeu Martínez, Eusebio |
| author |
Saez Landete, José |
| author_facet |
Saez Landete, José Alonso Fernández, José Bernabeu Martínez, Eusebio |
| author_role |
author |
| author2 |
Alonso Fernández, José Bernabeu Martínez, Eusebio |
| author2_role |
author author |
| dc.contributor.none.fl_str_mv |
Universidad Complutense de Madrid |
| dc.subject.none.fl_str_mv |
535 Accurate Alignment Bar Codes Systems Óptica (Física) 2209.19 Óptica Física |
| topic |
535 Accurate Alignment Bar Codes Systems Óptica (Física) 2209.19 Óptica Física |
| description |
The grating measurement systems can be used for displacement and angle measurements. They require of zero reference codes to obtain zero reference signals and absolute measures. The zero reference signals are obtained from the autocorrelation of two identical zero reference codes. The design of codes which generate optimum signals is rather complex, especially for larges codes. In this paper we present a global optimization method, a DIRECT algorithm for the design of zero reference codes. This method proves to be a powerful tool for solving this inverse problem. |
| publishDate |
2005 |
| dc.date.none.fl_str_mv |
2005 2005-01-10 2005 2005-01-10 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/20.500.14352/51199 |
| url |
https://hdl.handle.net/20.500.14352/51199 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
The Optical Society Of America |
| publisher.none.fl_str_mv |
The Optical Society Of America |
| dc.source.none.fl_str_mv |
reponame:Docta Complutense instname:Universidad Complutense de Madrid (UCM) |
| instname_str |
Universidad Complutense de Madrid (UCM) |
| reponame_str |
Docta Complutense |
| collection |
Docta Complutense |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869413056616857600 |
| score |
15,301603 |