Three-year follow-up of posterior chamber phakic intraocular lens with a central port design after deep anterior lamellar keratoplasty

Background: To evaluate clinical outcomes of the Visian implantable collamer lens (ICL) with a central port to correct myopia and astigmatism after deep anterior lamellar keratoplasty (DALK) for keratoconus throughout 3 years of follow-up. Methods: This study included 20 eyes of 20 patients that und...

ver descrição completa

Detalhes bibliográficos
Autores: Alfonso Bartolozzi, Belén, Lisa Fernández, Carlos, Fernández Vega-Cueto, Luis, Baamonde Arbaiza, Begoña, Madrid Costa, David, Alfonso Sánchez, José F.
Tipo de documento: artigo
Data de publicação:2022
País:España
Recursos:Universidad Complutense de Madrid (UCM)
Repositório:Docta Complutense
Idioma:inglês
OAI Identifier:oai:docta.ucm.es:20.500.14352/73300
Acesso em linha:https://hdl.handle.net/20.500.14352/73300
Access Level:Acceso aberto
Palavra-chave:617.713-089
617.7-089.243
681.73
DALK
Deep anterior lamellar keratoplasty
ICL
Implantable collamer lens.
Cirugía
Oftalmología
Optometría
3213 Cirugía
3201.09 Oftalmología
2209.15 Optometría
Descrição
Resumo:Background: To evaluate clinical outcomes of the Visian implantable collamer lens (ICL) with a central port to correct myopia and astigmatism after deep anterior lamellar keratoplasty (DALK) for keratoconus throughout 3 years of follow-up. Methods: This study included 20 eyes of 20 patients that underwent V4c ICL (13 eyes with a spherical ICL and 7 eyes with a toric ICL) implantation after DALK. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, intraocular pressure (IOP), endothelial cell density (ECD), and vault were analyzed. Results: The mean UDVA improved from the preoperative 1.18 ± 0.33 logMAR to 0.25 ± 0.14 logMAR at 6 months after surgery (P < 0.0001) and remained unchanged throughout the whole follow-up (P = 0.4). All eyes gained lines of CDVA compared to preoperative values. At the last follow-up visit, all eyes achieved CDVA of 0.2 logMAR or better and 13 eyes (65%) 0.1 logMAR or better. At 6 months post-surgery, all eyes (100%) had a spherical equivalent within ± 1.50 D, and 19 (95%) within ± 1.00 D. The mean manifest spherical equivalent was stable over the postoperative follow-up (P = 0.25). No significant increase in IOP occurred in any case throughout the 3 years of follow-up. The loss in ECD from the preoperative baseline at the last follow-up visit was 2.27%. Conclusions: The clinical outcomes suggest that the V4c ICL implantation for correction of myopia and regular astigmatism in post-DALK eyes was satisfactory in terms of effectiveness, safety, and stability during 3 years of follow-up.