Validation of Fixed Ultrasonography for Achilles Tendon Assessment: A Reliability Study

Background: It is important to highlight the advantages of ultrasound in assessing muscular and tendinous behavior due to its non-invasive nature and capacity for dynamic studies. However, evaluating tendons via ultrasound can be challenging given the complexity of anisotropic phenomena related to c...

Descripción completa

Detalles Bibliográficos
Autores: Alabau-Dasi, Raquel, Domínguez-Maldonado, Gabriel, Ortega-Ávila, Ana Belén, Gordillo Fernández, Luis María, Ortiz Romero, Mercedes, Gijón Noguerón, Gabriel
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2024
País:España
Institución:Universidad de Sevilla (US)
Repositorio:idUS. Depósito de Investigación de la Universidad de Sevilla
OAI Identifier:oai:dnet:idus________::d5b0e4542c3409c91a6a9090cb1209b1
Acceso en línea:https://hdl.handle.net/11441/186534
https://doi.org/10.3390/diagnostics14192221
Access Level:acceso abierto
Palabra clave:Achilles
Reliability
Tendon
Ultrasonography
Validation
Descripción
Sumario:Background: It is important to highlight the advantages of ultrasound in assessing muscular and tendinous behavior due to its non-invasive nature and capacity for dynamic studies. However, evaluating tendons via ultrasound can be challenging given the complexity of anisotropic phenomena related to collagen fiber arrangement. This study aims to validate the reliability of fixed ultrasound compared to manual acquisition in measuring Achilles tendon thickness. Method: Twenty participants, six men and fourteen women, were recruited. Ultrasound was used to measure the Achilles tendon’s thickness at two specific points (4 and 6 cm from the calcaneal insertion of the Achilles tendon). The measurements were conducted by two examiners, one with previous experience and another without. Results: The measurements at 6 cm from the calcaneal insertion showed α = 0.996, α = 0.998 for measurements at 4 cm using manual acquisition, and α = 0.997 for measurements with fixed ultrasound at rest. For the weight-bearing and ankle dorsiflexion measurements, the reliability was excellent (α = 0.999 and α = 1.000). Conclusions: The findings demonstrated excellent reliability in the ultrasound measurements of the Achilles tendon’s thickness, even when performed by different evaluators and under load-bearing conditions. This study suggests the clinical utility of assessing anatomical structures under load, enhancing ultrasound’s applicability beyond the examination table. It is concluded that fixed ultrasound acquisition exhibits excellent reliability in measuring the Achilles tendon’s thickness, offering potential benefits for precise diagnosis of pathologies, planning surgical interventions, and reducing possible errors related to operator variability.