Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access

(1) Objective. We aimed to demonstrate that the use of the ultrasound-guided technique facilitates peripheral venous cannulation as compared to the standard technique in patients with difficult access at emergency services. (2) Method. A case–control study, randomized research. Variables were collec...

Descripción completa

Detalles Bibliográficos
Autores: Rodríguez Herrera, María Ángeles, Solaz García, Álvaro José, Mollá Olmos, Enrique, Ferrer Puchol, Dolores, Esteve Claramunt, Francisca, Trujillo Barberá, Silvia, García Bermejo, Pedro, Casaña Mohedo, Jorge 
Tipo de recurso: artículo
Fecha de publicación:2022
País:España
Institución:Universidad Europea (UEM)
Repositorio:ABACUS. Repositorio de Producción Científica
Idioma:inglés
OAI Identifier:oai:abacus.universidadeuropea.com:11268/11283
Acceso en línea:http://hdl.handle.net/11268/11283
Access Level:acceso abierto
Palabra clave:Cánula
Servicios médicos de urgencia
Servicio de enfermería
Tecnología médica
Tratamiento médico
id ES_89e3abcbd1df30597bc3efbe95bee456
oai_identifier_str oai:abacus.universidadeuropea.com:11268/11283
network_acronym_str ES
network_name_str España
repository_id_str
spelling Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult AccessRodríguez Herrera, María ÁngelesSolaz García, Álvaro JoséMollá Olmos, EnriqueFerrer Puchol, DoloresEsteve Claramunt, FranciscaTrujillo Barberá, SilviaGarcía Bermejo, PedroCasaña Mohedo, Jorge CánulaServicios médicos de urgenciaServicio de enfermeríaTecnología médicaTratamiento médico(1) Objective. We aimed to demonstrate that the use of the ultrasound-guided technique facilitates peripheral venous cannulation as compared to the standard technique in patients with difficult access at emergency services. (2) Method. A case–control study, randomized research. Variables were collected from a population with non-palpable or not visible veins, classified into size risk groups for 6 months. In the comparative analysis, the patients were divided into two groups: the cases group was composed of patients to whom the peripheral venous cannulation was performed with the ultrasound-guided technique (UST), while the control was composed of patients with whom the standard technique (ST) was performed. The ultrasound LOGIQ P5 750VA from General Electric Healthcare, with an 11 mHz linear probe, was utilized, along with peripheral venous catheters model InsyteTM AutoguardTM with gauges of 14G to 26G. (3) Results. Seventy-two cases. The use of the ultrasound decreased the time (618.34s ST, 126s UST) and the number of punctures (2.92 ST, 1.23 UST); about 25% of the patients did not have complications with the UST, as compared to 8% with the ST. The use of the ultrasound decreased the pain experienced by 1.44 points in the visual analog scale, as compared to 0.11 points with the ST. The rate of success of the first try with the UST was 76%, as compared to 16% of the ST. The gauge of the catheter increased with the UST, with successful cannulations obtained with 20G (56%) and 18G (41%) gauges. (4) Conclusions. The use of ultrasound facilitates venous cannulation according to the variables of the study. The ultrasound visualization of the vessels is associated with the selection of the catheter gauge. There was no relation between the complications and the depth of the blood vessels.20222022-05-2420222022-01-0120222022-01-01journal articlehttp://purl.org/coar/resource_type/c_6501info:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/11268/11283reponame:ABACUS. Repositorio de Producción Científicainstname:Universidad Europea (UEM)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Atribución 4.0 Internacionalhttp://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:abacus.universidadeuropea.com:11268/112832026-06-11T12:41:27Z
dc.title.none.fl_str_mv Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access
title Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access
spellingShingle Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access
Rodríguez Herrera, María Ángeles
Cánula
Servicios médicos de urgencia
Servicio de enfermería
Tecnología médica
Tratamiento médico
title_short Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access
title_full Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access
title_fullStr Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access
title_full_unstemmed Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access
title_sort Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access
dc.creator.none.fl_str_mv Rodríguez Herrera, María Ángeles
Solaz García, Álvaro José
Mollá Olmos, Enrique
Ferrer Puchol, Dolores
Esteve Claramunt, Francisca
Trujillo Barberá, Silvia
García Bermejo, Pedro
Casaña Mohedo, Jorge 
author Rodríguez Herrera, María Ángeles
author_facet Rodríguez Herrera, María Ángeles
Solaz García, Álvaro José
Mollá Olmos, Enrique
Ferrer Puchol, Dolores
Esteve Claramunt, Francisca
Trujillo Barberá, Silvia
García Bermejo, Pedro
Casaña Mohedo, Jorge 
author_role author
author2 Solaz García, Álvaro José
Mollá Olmos, Enrique
Ferrer Puchol, Dolores
Esteve Claramunt, Francisca
Trujillo Barberá, Silvia
García Bermejo, Pedro
Casaña Mohedo, Jorge 
author2_role author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv
dc.subject.none.fl_str_mv Cánula
Servicios médicos de urgencia
Servicio de enfermería
Tecnología médica
Tratamiento médico
topic Cánula
Servicios médicos de urgencia
Servicio de enfermería
Tecnología médica
Tratamiento médico
description (1) Objective. We aimed to demonstrate that the use of the ultrasound-guided technique facilitates peripheral venous cannulation as compared to the standard technique in patients with difficult access at emergency services. (2) Method. A case–control study, randomized research. Variables were collected from a population with non-palpable or not visible veins, classified into size risk groups for 6 months. In the comparative analysis, the patients were divided into two groups: the cases group was composed of patients to whom the peripheral venous cannulation was performed with the ultrasound-guided technique (UST), while the control was composed of patients with whom the standard technique (ST) was performed. The ultrasound LOGIQ P5 750VA from General Electric Healthcare, with an 11 mHz linear probe, was utilized, along with peripheral venous catheters model InsyteTM AutoguardTM with gauges of 14G to 26G. (3) Results. Seventy-two cases. The use of the ultrasound decreased the time (618.34s ST, 126s UST) and the number of punctures (2.92 ST, 1.23 UST); about 25% of the patients did not have complications with the UST, as compared to 8% with the ST. The use of the ultrasound decreased the pain experienced by 1.44 points in the visual analog scale, as compared to 0.11 points with the ST. The rate of success of the first try with the UST was 76%, as compared to 16% of the ST. The gauge of the catheter increased with the UST, with successful cannulations obtained with 20G (56%) and 18G (41%) gauges. (4) Conclusions. The use of ultrasound facilitates venous cannulation according to the variables of the study. The ultrasound visualization of the vessels is associated with the selection of the catheter gauge. There was no relation between the complications and the depth of the blood vessels.
publishDate 2022
dc.date.none.fl_str_mv 2022
2022-05-24
2022
2022-01-01
2022
2022-01-01
dc.type.none.fl_str_mv journal article
http://purl.org/coar/resource_type/c_6501
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv http://hdl.handle.net/11268/11283
url http://hdl.handle.net/11268/11283
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
Atribución 4.0 Internacional
http://creativecommons.org/licenses/by/4.0/
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
Atribución 4.0 Internacional
http://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:ABACUS. Repositorio de Producción Científica
instname:Universidad Europea (UEM)
instname_str Universidad Europea (UEM)
reponame_str ABACUS. Repositorio de Producción Científica
collection ABACUS. Repositorio de Producción Científica
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869412660600111104
score 15.301629