Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access
(1) Objective. We aimed to demonstrate that the use of the ultrasound-guided technique facilitates peripheral venous cannulation as compared to the standard technique in patients with difficult access at emergency services. (2) Method. A case–control study, randomized research. Variables were collec...
| Autores: | , , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2022 |
| País: | España |
| Institución: | Universidad Europea (UEM) |
| Repositorio: | ABACUS. Repositorio de Producción Científica |
| Idioma: | inglés |
| OAI Identifier: | oai:abacus.universidadeuropea.com:11268/11283 |
| Acceso en línea: | http://hdl.handle.net/11268/11283 |
| Access Level: | acceso abierto |
| Palabra clave: | Cánula Servicios médicos de urgencia Servicio de enfermería Tecnología médica Tratamiento médico |
| id |
ES_89e3abcbd1df30597bc3efbe95bee456 |
|---|---|
| oai_identifier_str |
oai:abacus.universidadeuropea.com:11268/11283 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult AccessRodríguez Herrera, María ÁngelesSolaz García, Álvaro JoséMollá Olmos, EnriqueFerrer Puchol, DoloresEsteve Claramunt, FranciscaTrujillo Barberá, SilviaGarcía Bermejo, PedroCasaña Mohedo, Jorge CánulaServicios médicos de urgenciaServicio de enfermeríaTecnología médicaTratamiento médico(1) Objective. We aimed to demonstrate that the use of the ultrasound-guided technique facilitates peripheral venous cannulation as compared to the standard technique in patients with difficult access at emergency services. (2) Method. A case–control study, randomized research. Variables were collected from a population with non-palpable or not visible veins, classified into size risk groups for 6 months. In the comparative analysis, the patients were divided into two groups: the cases group was composed of patients to whom the peripheral venous cannulation was performed with the ultrasound-guided technique (UST), while the control was composed of patients with whom the standard technique (ST) was performed. The ultrasound LOGIQ P5 750VA from General Electric Healthcare, with an 11 mHz linear probe, was utilized, along with peripheral venous catheters model InsyteTM AutoguardTM with gauges of 14G to 26G. (3) Results. Seventy-two cases. The use of the ultrasound decreased the time (618.34s ST, 126s UST) and the number of punctures (2.92 ST, 1.23 UST); about 25% of the patients did not have complications with the UST, as compared to 8% with the ST. The use of the ultrasound decreased the pain experienced by 1.44 points in the visual analog scale, as compared to 0.11 points with the ST. The rate of success of the first try with the UST was 76%, as compared to 16% of the ST. The gauge of the catheter increased with the UST, with successful cannulations obtained with 20G (56%) and 18G (41%) gauges. (4) Conclusions. The use of ultrasound facilitates venous cannulation according to the variables of the study. The ultrasound visualization of the vessels is associated with the selection of the catheter gauge. There was no relation between the complications and the depth of the blood vessels.20222022-05-2420222022-01-0120222022-01-01journal articlehttp://purl.org/coar/resource_type/c_6501info:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/11268/11283reponame:ABACUS. Repositorio de Producción Científicainstname:Universidad Europea (UEM)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Atribución 4.0 Internacionalhttp://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:abacus.universidadeuropea.com:11268/112832026-06-11T12:41:27Z |
| dc.title.none.fl_str_mv |
Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access |
| title |
Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access |
| spellingShingle |
Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access Rodríguez Herrera, María Ángeles Cánula Servicios médicos de urgencia Servicio de enfermería Tecnología médica Tratamiento médico |
| title_short |
Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access |
| title_full |
Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access |
| title_fullStr |
Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access |
| title_full_unstemmed |
Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access |
| title_sort |
Use of the Ultrasound Technique as Compared to the Standard Technique for the Improvement of Venous Cannulation in Patients with Difficult Access |
| dc.creator.none.fl_str_mv |
Rodríguez Herrera, María Ángeles Solaz García, Álvaro José Mollá Olmos, Enrique Ferrer Puchol, Dolores Esteve Claramunt, Francisca Trujillo Barberá, Silvia García Bermejo, Pedro Casaña Mohedo, Jorge |
| author |
Rodríguez Herrera, María Ángeles |
| author_facet |
Rodríguez Herrera, María Ángeles Solaz García, Álvaro José Mollá Olmos, Enrique Ferrer Puchol, Dolores Esteve Claramunt, Francisca Trujillo Barberá, Silvia García Bermejo, Pedro Casaña Mohedo, Jorge |
| author_role |
author |
| author2 |
Solaz García, Álvaro José Mollá Olmos, Enrique Ferrer Puchol, Dolores Esteve Claramunt, Francisca Trujillo Barberá, Silvia García Bermejo, Pedro Casaña Mohedo, Jorge |
| author2_role |
author author author author author author author |
| dc.contributor.none.fl_str_mv |
|
| dc.subject.none.fl_str_mv |
Cánula Servicios médicos de urgencia Servicio de enfermería Tecnología médica Tratamiento médico |
| topic |
Cánula Servicios médicos de urgencia Servicio de enfermería Tecnología médica Tratamiento médico |
| description |
(1) Objective. We aimed to demonstrate that the use of the ultrasound-guided technique facilitates peripheral venous cannulation as compared to the standard technique in patients with difficult access at emergency services. (2) Method. A case–control study, randomized research. Variables were collected from a population with non-palpable or not visible veins, classified into size risk groups for 6 months. In the comparative analysis, the patients were divided into two groups: the cases group was composed of patients to whom the peripheral venous cannulation was performed with the ultrasound-guided technique (UST), while the control was composed of patients with whom the standard technique (ST) was performed. The ultrasound LOGIQ P5 750VA from General Electric Healthcare, with an 11 mHz linear probe, was utilized, along with peripheral venous catheters model InsyteTM AutoguardTM with gauges of 14G to 26G. (3) Results. Seventy-two cases. The use of the ultrasound decreased the time (618.34s ST, 126s UST) and the number of punctures (2.92 ST, 1.23 UST); about 25% of the patients did not have complications with the UST, as compared to 8% with the ST. The use of the ultrasound decreased the pain experienced by 1.44 points in the visual analog scale, as compared to 0.11 points with the ST. The rate of success of the first try with the UST was 76%, as compared to 16% of the ST. The gauge of the catheter increased with the UST, with successful cannulations obtained with 20G (56%) and 18G (41%) gauges. (4) Conclusions. The use of ultrasound facilitates venous cannulation according to the variables of the study. The ultrasound visualization of the vessels is associated with the selection of the catheter gauge. There was no relation between the complications and the depth of the blood vessels. |
| publishDate |
2022 |
| dc.date.none.fl_str_mv |
2022 2022-05-24 2022 2022-01-01 2022 2022-01-01 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/11268/11283 |
| url |
http://hdl.handle.net/11268/11283 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Atribución 4.0 Internacional http://creativecommons.org/licenses/by/4.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Atribución 4.0 Internacional http://creativecommons.org/licenses/by/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.source.none.fl_str_mv |
reponame:ABACUS. Repositorio de Producción Científica instname:Universidad Europea (UEM) |
| instname_str |
Universidad Europea (UEM) |
| reponame_str |
ABACUS. Repositorio de Producción Científica |
| collection |
ABACUS. Repositorio de Producción Científica |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869412660600111104 |
| score |
15.301629 |