The Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Plantar Fascia and Flexor Digitorum Brevis Interface: An Anatomical Study

Background: Evidence suggests the plantar fascia and its interphase with the flexor digitorum brevis muscle can play a relevant role in plantar heel pain. Needling interventions could offer an appropriate treatment strategy to addressing this interface. Objective: We compared the accuracy and safety...

ver descrição completa

Detalhes bibliográficos
Autores: Malo-Urriés, Miguel, Borrella-Andrés, Sergio, López-de-Celis, Carlos, Fernández-de-las-Peñas, César, Pérez-Bellmunt, Albert, Arias-Buría, José L., Albarova-Corral, Isabel, Rodríguez-Sanz, Jacobo
Formato: artículo
Estado:Versión publicada
Fecha de publicación:2024
País:España
Recursos:Universidad de Zaragoza
Repositorio:Zaguán. Repositorio Digital de la Universidad de Zaragoza
OAI Identifier:oai:zaguan.unizar.es:135490
Acesso em linha:http://zaguan.unizar.es/record/135490
Access Level:acceso abierto
id ES_899fac0536138159b746d4bf69fcffcb
oai_identifier_str oai:zaguan.unizar.es:135490
network_acronym_str ES
network_name_str España
repository_id_str
spelling The Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Plantar Fascia and Flexor Digitorum Brevis Interface: An Anatomical StudyMalo-Urriés, MiguelBorrella-Andrés, SergioLópez-de-Celis, CarlosFernández-de-las-Peñas, CésarPérez-Bellmunt, AlbertArias-Buría, José L.Albarova-Corral, IsabelRodríguez-Sanz, JacoboBackground: Evidence suggests the plantar fascia and its interphase with the flexor digitorum brevis muscle can play a relevant role in plantar heel pain. Needling interventions could offer an appropriate treatment strategy to addressing this interface. Objective: We compared the accuracy and safety of ultrasound-guided versus palpation-guided procedures for the proper targeting of the interface between the plantar fascia and the flexor digitorum brevis with a solid needle. Methods: A crossover cadaveric study was conducted. Five experienced therapists performed a series of 20 needle insertions each (n = 100 in total, 10 landmark-guided and 10 ultrasound-guided) on 10 anatomical samples. The therapists were instructed to accurately place the needle on the interface between the plantar fascia and the flexor digitorum brevis muscle. The distance of the tip of the needle to the identified target (accuracy), the surrounding sensitive structures targeted (safety), the time needed for the procedure, the number of needle passes, and the needle length outside the skin were assessed. Results: The ultrasound-guided technique was associated with a significantly higher accuracy (p < 0.001) but without differences in safety (p = 0.249) as compared to the palpation-guided procedure. Conclusion: Our results suggest that ultrasound-guided insertion exhibits greater accuracy but not greater safety than palpation-guided insertion when targeting the interface between the plantar fascia and the flexor digitorum brevis.2024info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://zaguan.unizar.es/record/135490reponame:Zaguán. Repositorio Digital de la Universidad de Zaragozainstname:Universidad de ZaragozaInglésinfo:eu-repo/semantics/openAccessoai:zaguan.unizar.es:1354902026-05-29T13:59:51Z
dc.title.none.fl_str_mv The Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Plantar Fascia and Flexor Digitorum Brevis Interface: An Anatomical Study
title The Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Plantar Fascia and Flexor Digitorum Brevis Interface: An Anatomical Study
spellingShingle The Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Plantar Fascia and Flexor Digitorum Brevis Interface: An Anatomical Study
Malo-Urriés, Miguel
title_short The Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Plantar Fascia and Flexor Digitorum Brevis Interface: An Anatomical Study
title_full The Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Plantar Fascia and Flexor Digitorum Brevis Interface: An Anatomical Study
title_fullStr The Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Plantar Fascia and Flexor Digitorum Brevis Interface: An Anatomical Study
title_full_unstemmed The Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Plantar Fascia and Flexor Digitorum Brevis Interface: An Anatomical Study
title_sort The Precision and Safety of Ultrasound-Guided versus Palpation-Guided Needle Placement on the Plantar Fascia and Flexor Digitorum Brevis Interface: An Anatomical Study
dc.creator.none.fl_str_mv Malo-Urriés, Miguel
Borrella-Andrés, Sergio
López-de-Celis, Carlos
Fernández-de-las-Peñas, César
Pérez-Bellmunt, Albert
Arias-Buría, José L.
Albarova-Corral, Isabel
Rodríguez-Sanz, Jacobo
author Malo-Urriés, Miguel
author_facet Malo-Urriés, Miguel
Borrella-Andrés, Sergio
López-de-Celis, Carlos
Fernández-de-las-Peñas, César
Pérez-Bellmunt, Albert
Arias-Buría, José L.
Albarova-Corral, Isabel
Rodríguez-Sanz, Jacobo
author_role author
author2 Borrella-Andrés, Sergio
López-de-Celis, Carlos
Fernández-de-las-Peñas, César
Pérez-Bellmunt, Albert
Arias-Buría, José L.
Albarova-Corral, Isabel
Rodríguez-Sanz, Jacobo
author2_role author
author
author
author
author
author
author
description Background: Evidence suggests the plantar fascia and its interphase with the flexor digitorum brevis muscle can play a relevant role in plantar heel pain. Needling interventions could offer an appropriate treatment strategy to addressing this interface. Objective: We compared the accuracy and safety of ultrasound-guided versus palpation-guided procedures for the proper targeting of the interface between the plantar fascia and the flexor digitorum brevis with a solid needle. Methods: A crossover cadaveric study was conducted. Five experienced therapists performed a series of 20 needle insertions each (n = 100 in total, 10 landmark-guided and 10 ultrasound-guided) on 10 anatomical samples. The therapists were instructed to accurately place the needle on the interface between the plantar fascia and the flexor digitorum brevis muscle. The distance of the tip of the needle to the identified target (accuracy), the surrounding sensitive structures targeted (safety), the time needed for the procedure, the number of needle passes, and the needle length outside the skin were assessed. Results: The ultrasound-guided technique was associated with a significantly higher accuracy (p < 0.001) but without differences in safety (p = 0.249) as compared to the palpation-guided procedure. Conclusion: Our results suggest that ultrasound-guided insertion exhibits greater accuracy but not greater safety than palpation-guided insertion when targeting the interface between the plantar fascia and the flexor digitorum brevis.
publishDate 2024
dc.date.none.fl_str_mv 2024
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://zaguan.unizar.es/record/135490
url http://zaguan.unizar.es/record/135490
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv
publisher.none.fl_str_mv
dc.source.none.fl_str_mv reponame:Zaguán. Repositorio Digital de la Universidad de Zaragoza
instname:Universidad de Zaragoza
instname_str Universidad de Zaragoza
reponame_str Zaguán. Repositorio Digital de la Universidad de Zaragoza
collection Zaguán. Repositorio Digital de la Universidad de Zaragoza
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869412641132249088
score 15,198674