Effect of stimulus duration on estimates of human cochlear tuning

[EN] Auditory masking methods originally employed to assess behavioral frequency selectivity have evolved over the years to infer cochlear tuning. Behavioral forward masking thresholds for spectrally notched noise maskers and a fixed, low-level probe tone provide accurate estimates of cochlear tunin...

ver descrição completa

Detalhes bibliográficos
Autores: López Ramos, David, Eustaquio Martín, María Almudena, López Bascuas, Luis E., López-Poveda, Enrique A.
Formato: artículo
Estado:Versión publicada
Fecha de publicación:2024
País:España
Recursos:Universidad de Salamanca (USAL)
Repositorio:GREDOS. Repositorio Institucional de la Universidad de Salamanca
OAI Identifier:oai:gredos.usal.es:10366/167665
Acesso em linha:http://hdl.handle.net/10366/167665
Access Level:acceso abierto
Palavra-chave:Acoustic reflex
Auditory filter
Forward masking
Notched-noise method
Olivocochlear reflex
2411.13 Fisiología de la Audición
2201.03 Física de la Audición
3201.09 Oftalmología
Descrição
Resumo:[EN] Auditory masking methods originally employed to assess behavioral frequency selectivity have evolved over the years to infer cochlear tuning. Behavioral forward masking thresholds for spectrally notched noise maskers and a fixed, low-level probe tone provide accurate estimates of cochlear tuning. Here, we use this method to investigate the effect of stimulus duration on human cochlear tuning at 500 Hz and 4 kHz. Probes were 20-ms sinusoids at 10 dB sensation level. Maskers were noises with a spectral notch symmetrically and asymmetrically placed around the probe frequency. For seven participants with normal hearing, masker levels at masking threshold were measured in forward masking for various notch widths and for masker durations of 30 and 400 ms. Measurements were fitted assuming rounded exponential filter shapes and the power spectrum model of masking, and equivalent rectangular bandwidths (ERBs) were inferred from the fits. At 4 kHz, masker thresholds were higher for the shorter maskers but ERBs were not significantly different for the two masker durations (ERB30ms=294 Hz vs. ERB400ms=277 Hz). At 500 Hz, by contrast, notched-noise curves were shallower for the 30-ms than the 400-ms masker, and ERBs were significantly broader for the shorter masker (ERB30ms=126 Hz vs. ERB400ms=55 Hz). We discuss possible factors that may underlay the duration effect at low frequencies and argue that it may not be possible to fully control for those factors. We conclude that tuning estimates are not affected by maker duration at high frequencies but should be measured and interpreted with caution at low frequencies.