Metrology for advanced radiotherapy using particle beams with ultra-high dose rates
Dosimetry of ultra-high dose rate beams is one of the critical components which is required for safe implementation of FLASH radiotherapy (RT) into clinical practice. In the past years several national and international programmes have emerged with the aim to address some of the needs that are requi...
| Autores: | , , , , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2024 |
| País: | España |
| Institución: | Consejo Superior de Investigaciones Científicas (CSIC) |
| Repositorio: | DIGITAL.CSIC. Repositorio Institucional del CSIC |
| OAI Identifier: | oai:digital.csic.es:10261/395474 |
| Acceso en línea: | http://hdl.handle.net/10261/395474 https://api.elsevier.com/content/abstract/scopus_id/85197977261 |
| Access Level: | acceso abierto |
| Palabra clave: | Fricke Alanine Calorimetry Dosimetry FlashDiamond Ionization chambers Silicon carbide http://metadata.un.org/sdg/3 Ensure healthy lives and promote well-being for all at all ages |
| id |
ES_81ebb3ccf09cfb655917b9f9e6b53fbb |
|---|---|
| oai_identifier_str |
oai:digital.csic.es:10261/395474 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Metrology for advanced radiotherapy using particle beams with ultra-high dose ratesSubiel, AnnaBourgouin, AlexandraKranzer, RafaelPeier, PeterFrei, FranziskaGomez, FaustinoKnyziak, AdrianFleta, CelesteBailat, ClaudeSchüller, AndreasFrickeAlanineCalorimetryDosimetryFlashDiamondIonization chambersSilicon carbidehttp://metadata.un.org/sdg/3Ensure healthy lives and promote well-being for all at all agesDosimetry of ultra-high dose rate beams is one of the critical components which is required for safe implementation of FLASH radiotherapy (RT) into clinical practice. In the past years several national and international programmes have emerged with the aim to address some of the needs that are required for translation of this modality to clinics. These involve the establishment of dosimetry standards as well as the validation of protocols and dosimetry procedures. This review provides an overview of recent developments in the field of dosimetry for FLASH RT, with particular focus on primary and secondary standard instruments, and provides a brief outlook on the future work which is required to enable clinical implementation of FLASH RT.This project 18HLT04 UHDpulse has received funding from the EMPIR programme co-financed by the Participating States and from the European Union\u2019s Horizon 2020 research and innovation programmePeer reviewedIOP PublishingEuropean Metrology Research ProgrammeEuropean CommissionSubiel, Anna [0000-0002-3467-4631]Bourgouin, Alexandra [0000-0001-6429-4122]Kranzer, Rafael [0000-0003-4063-0413]Fleta, Celeste [0000-0002-6591-6744]Schüller, Andreas [0000-0002-0355-299X]Consejo Superior de Investigaciones Científicas [https://ror.org/02gfc7t72]202520252024info:eu-repo/semantics/articlehttp://purl.org/coar/resource_type/c_6501Publisher's versioninfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/10261/395474https://api.elsevier.com/content/abstract/scopus_id/85197977261reponame:DIGITAL.CSIC. Repositorio Institucional del CSICinstname:Consejo Superior de Investigaciones Científicas (CSIC)Inglés#PLACEHOLDER_PARENT_METADATA_VALUE#info:eu-repo/grantAgreement/EC/H2020/18HLT04 UHDhttps://doi.org/10.1088/1361-6560/ad539dSíinfo:eu-repo/semantics/openAccessoai:digital.csic.es:10261/3954742026-05-22T06:33:51Z |
| dc.title.none.fl_str_mv |
Metrology for advanced radiotherapy using particle beams with ultra-high dose rates |
| title |
Metrology for advanced radiotherapy using particle beams with ultra-high dose rates |
| spellingShingle |
Metrology for advanced radiotherapy using particle beams with ultra-high dose rates Subiel, Anna Fricke Alanine Calorimetry Dosimetry FlashDiamond Ionization chambers Silicon carbide http://metadata.un.org/sdg/3 Ensure healthy lives and promote well-being for all at all ages |
| title_short |
Metrology for advanced radiotherapy using particle beams with ultra-high dose rates |
| title_full |
Metrology for advanced radiotherapy using particle beams with ultra-high dose rates |
| title_fullStr |
Metrology for advanced radiotherapy using particle beams with ultra-high dose rates |
| title_full_unstemmed |
Metrology for advanced radiotherapy using particle beams with ultra-high dose rates |
| title_sort |
Metrology for advanced radiotherapy using particle beams with ultra-high dose rates |
| dc.creator.none.fl_str_mv |
Subiel, Anna Bourgouin, Alexandra Kranzer, Rafael Peier, Peter Frei, Franziska Gomez, Faustino Knyziak, Adrian Fleta, Celeste Bailat, Claude Schüller, Andreas |
| author |
Subiel, Anna |
| author_facet |
Subiel, Anna Bourgouin, Alexandra Kranzer, Rafael Peier, Peter Frei, Franziska Gomez, Faustino Knyziak, Adrian Fleta, Celeste Bailat, Claude Schüller, Andreas |
| author_role |
author |
| author2 |
Bourgouin, Alexandra Kranzer, Rafael Peier, Peter Frei, Franziska Gomez, Faustino Knyziak, Adrian Fleta, Celeste Bailat, Claude Schüller, Andreas |
| author2_role |
author author author author author author author author author |
| dc.contributor.none.fl_str_mv |
European Metrology Research Programme European Commission Subiel, Anna [0000-0002-3467-4631] Bourgouin, Alexandra [0000-0001-6429-4122] Kranzer, Rafael [0000-0003-4063-0413] Fleta, Celeste [0000-0002-6591-6744] Schüller, Andreas [0000-0002-0355-299X] Consejo Superior de Investigaciones Científicas [https://ror.org/02gfc7t72] |
| dc.subject.none.fl_str_mv |
Fricke Alanine Calorimetry Dosimetry FlashDiamond Ionization chambers Silicon carbide http://metadata.un.org/sdg/3 Ensure healthy lives and promote well-being for all at all ages |
| topic |
Fricke Alanine Calorimetry Dosimetry FlashDiamond Ionization chambers Silicon carbide http://metadata.un.org/sdg/3 Ensure healthy lives and promote well-being for all at all ages |
| description |
Dosimetry of ultra-high dose rate beams is one of the critical components which is required for safe implementation of FLASH radiotherapy (RT) into clinical practice. In the past years several national and international programmes have emerged with the aim to address some of the needs that are required for translation of this modality to clinics. These involve the establishment of dosimetry standards as well as the validation of protocols and dosimetry procedures. This review provides an overview of recent developments in the field of dosimetry for FLASH RT, with particular focus on primary and secondary standard instruments, and provides a brief outlook on the future work which is required to enable clinical implementation of FLASH RT. |
| publishDate |
2024 |
| dc.date.none.fl_str_mv |
2024 2025 2025 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article http://purl.org/coar/resource_type/c_6501 Publisher's version info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/10261/395474 https://api.elsevier.com/content/abstract/scopus_id/85197977261 |
| url |
http://hdl.handle.net/10261/395474 https://api.elsevier.com/content/abstract/scopus_id/85197977261 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
#PLACEHOLDER_PARENT_METADATA_VALUE# info:eu-repo/grantAgreement/EC/H2020/18HLT04 UHD https://doi.org/10.1088/1361-6560/ad539d Sí |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
IOP Publishing |
| publisher.none.fl_str_mv |
IOP Publishing |
| dc.source.none.fl_str_mv |
reponame:DIGITAL.CSIC. Repositorio Institucional del CSIC instname:Consejo Superior de Investigaciones Científicas (CSIC) |
| instname_str |
Consejo Superior de Investigaciones Científicas (CSIC) |
| reponame_str |
DIGITAL.CSIC. Repositorio Institucional del CSIC |
| collection |
DIGITAL.CSIC. Repositorio Institucional del CSIC |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869412009000304640 |
| score |
15,812429 |