Removal of microbial indicators from municipal wastewater by a membrane bioreactor (MBR)

The impact of removable and irremovable fouling on the retention of viral and bacterial indicators by the submerged microfiltration membrane in an MBR pilot plant was evaluated. Escherichia coli, sulphite-reducing Clostridium spores, somatic coliphages and F-specific RNA bacteriophages were used as...

Full description

Bibliographic Details
Authors: Martí Serrano, Elisabet, Monclús Sales, Hèctor, Jofre, Juan, Rodríguez-Roda Layret, Ignasi, Comas Matas, Joaquim, Balcázar, José Luis
Format: article
Status:Published version
Publication Date:2011
Country:España
Institution:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
Repository:Recercat. Dipósit de la Recerca de Catalunya
OAI Identifier:oai:recercat.cat:10256/12524
Online Access:http://hdl.handle.net/10256/12524
Access Level:Embargoed access
Keyword:Bioreactors
Reactors de membrana
Membrane reactors
Membranes (Tecnologia)
Membranes (Technology)
Aigües residuals -- Microbiologia
Sewage -- Microbiology
id ES_81786e7e5bdfc214a0c8dbffd0442370
oai_identifier_str oai:recercat.cat:10256/12524
network_acronym_str ES
network_name_str España
repository_id_str
spelling Removal of microbial indicators from municipal wastewater by a membrane bioreactor (MBR)Martí Serrano, ElisabetMonclús Sales, HèctorJofre, JuanRodríguez-Roda Layret, IgnasiComas Matas, JoaquimBalcázar, José LuisBioreactorsReactors de membranaMembrane reactorsMembranes (Tecnologia)Membranes (Technology)Aigües residuals -- MicrobiologiaSewage -- MicrobiologyThe impact of removable and irremovable fouling on the retention of viral and bacterial indicators by the submerged microfiltration membrane in an MBR pilot plant was evaluated. Escherichia coli, sulphite-reducing Clostridium spores, somatic coliphages and F-specific RNA bacteriophages were used as indicators. The membrane demonstrated almost complete removal of E. coli and sulphite-reducing Clostridium spores. However, there was no correlation with membrane fouling. The phage removal varied in accordance with the irremovable fouling, rising from 2.6 to 5.6 log10 units as the irremovable fouling increased (measured by the change in the transmembrane pressure). In contrast, removable fouling did not have any effect on the retention of viruses by the membrane. These results indicate that irremovable membrane fouling may affect the removal efficiency of MBRs and, therefore, their capacity to ensure the required microbiological standards for the permeate achievedThis research was partially funded by the Spanish Ministry of Education and Science and Innovation (CTM2009-14742-C02-01) and (CONSOLIDER-CSD2007-00055)ElsevierMinisterio de Ciencia y Tecnología (Espanya)Ministerio de Educación y Ciencia (Espanya)infoinfo2011info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/10256/12524http://hdl.handle.net/10256/12524© Bioresource Technology, 2011, vol. 102, núm. 8, p. 5004-5009Articles publicats (D-EQATA)reponame:Recercat. Dipósit de la Recerca de Catalunyainstname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)Inglésinfo:eu-repo/semantics/altIdentifier/doi/10.1016/j.biortech.2011.01.068info:eu-repo/semantics/altIdentifier/issn/0960-8524MICYT/2009-2011/CTM2009-14742-C02-01info:eu-repo/grantAgreement/MEC//CSD2007-00055Tots els drets reservatsinfo:eu-repo/semantics/embargoedAccessoai:recercat.cat:10256/125242026-05-29T05:05:01Z
dc.title.none.fl_str_mv Removal of microbial indicators from municipal wastewater by a membrane bioreactor (MBR)
title Removal of microbial indicators from municipal wastewater by a membrane bioreactor (MBR)
spellingShingle Removal of microbial indicators from municipal wastewater by a membrane bioreactor (MBR)
Martí Serrano, Elisabet
Bioreactors
Reactors de membrana
Membrane reactors
Membranes (Tecnologia)
Membranes (Technology)
Aigües residuals -- Microbiologia
Sewage -- Microbiology
title_short Removal of microbial indicators from municipal wastewater by a membrane bioreactor (MBR)
title_full Removal of microbial indicators from municipal wastewater by a membrane bioreactor (MBR)
title_fullStr Removal of microbial indicators from municipal wastewater by a membrane bioreactor (MBR)
title_full_unstemmed Removal of microbial indicators from municipal wastewater by a membrane bioreactor (MBR)
title_sort Removal of microbial indicators from municipal wastewater by a membrane bioreactor (MBR)
dc.creator.none.fl_str_mv Martí Serrano, Elisabet
Monclús Sales, Hèctor
Jofre, Juan
Rodríguez-Roda Layret, Ignasi
Comas Matas, Joaquim
Balcázar, José Luis
author Martí Serrano, Elisabet
author_facet Martí Serrano, Elisabet
Monclús Sales, Hèctor
Jofre, Juan
Rodríguez-Roda Layret, Ignasi
Comas Matas, Joaquim
Balcázar, José Luis
author_role author
author2 Monclús Sales, Hèctor
Jofre, Juan
Rodríguez-Roda Layret, Ignasi
Comas Matas, Joaquim
Balcázar, José Luis
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Ministerio de Ciencia y Tecnología (Espanya)
Ministerio de Educación y Ciencia (Espanya)
dc.subject.none.fl_str_mv Bioreactors
Reactors de membrana
Membrane reactors
Membranes (Tecnologia)
Membranes (Technology)
Aigües residuals -- Microbiologia
Sewage -- Microbiology
topic Bioreactors
Reactors de membrana
Membrane reactors
Membranes (Tecnologia)
Membranes (Technology)
Aigües residuals -- Microbiologia
Sewage -- Microbiology
description The impact of removable and irremovable fouling on the retention of viral and bacterial indicators by the submerged microfiltration membrane in an MBR pilot plant was evaluated. Escherichia coli, sulphite-reducing Clostridium spores, somatic coliphages and F-specific RNA bacteriophages were used as indicators. The membrane demonstrated almost complete removal of E. coli and sulphite-reducing Clostridium spores. However, there was no correlation with membrane fouling. The phage removal varied in accordance with the irremovable fouling, rising from 2.6 to 5.6 log10 units as the irremovable fouling increased (measured by the change in the transmembrane pressure). In contrast, removable fouling did not have any effect on the retention of viruses by the membrane. These results indicate that irremovable membrane fouling may affect the removal efficiency of MBRs and, therefore, their capacity to ensure the required microbiological standards for the permeate achieved
publishDate 2011
dc.date.none.fl_str_mv 2011
info
info
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/10256/12524
http://hdl.handle.net/10256/12524
url http://hdl.handle.net/10256/12524
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv info:eu-repo/semantics/altIdentifier/doi/10.1016/j.biortech.2011.01.068
info:eu-repo/semantics/altIdentifier/issn/0960-8524
MICYT/2009-2011/CTM2009-14742-C02-01
info:eu-repo/grantAgreement/MEC//CSD2007-00055
dc.rights.none.fl_str_mv Tots els drets reservats
info:eu-repo/semantics/embargoedAccess
rights_invalid_str_mv Tots els drets reservats
eu_rights_str_mv embargoedAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv © Bioresource Technology, 2011, vol. 102, núm. 8, p. 5004-5009
Articles publicats (D-EQATA)
reponame:Recercat. Dipósit de la Recerca de Catalunya
instname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
instname_str Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
reponame_str Recercat. Dipósit de la Recerca de Catalunya
collection Recercat. Dipósit de la Recerca de Catalunya
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869411975946043392
score 15,81155