Optimized cross-polarized LEKIDs for W-band using sawtooth inductors
Lumped-element kinetic inductance detectors (LEKIDs) based on sawtooth inductors for W -band are presented in this article. A careful analysis is carried out for the cross-polarization in the inductor geometry, which brings out the absorption of the nondesired E -field component of an incident wave...
| Autores: | , , , , , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2024 |
| País: | España |
| Institución: | Universidad de Zaragoza |
| Repositorio: | Zaguán. Repositorio Digital de la Universidad de Zaragoza |
| OAI Identifier: | oai:zaguan.unizar.es:130138 |
| Acceso en línea: | http://zaguan.unizar.es/record/130138 |
| Access Level: | acceso abierto |
| id |
ES_812aca4bf38f814ef2091ef616a6d36e |
|---|---|
| oai_identifier_str |
oai:zaguan.unizar.es:130138 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Optimized cross-polarized LEKIDs for W-band using sawtooth inductorsDe Ory, Marina C.Rodriguez, DavidVilla, EnriqueDe la Fuente, LuisaAja, BeatrizRollano, VictorMagaz, María TeresaPascual, Juan P.Granados, DanielArtal, EduardoGomez, AliciaLumped-element kinetic inductance detectors (LEKIDs) based on sawtooth inductors for W -band are presented in this article. A careful analysis is carried out for the cross-polarization in the inductor geometry, which brings out the absorption of the nondesired E -field component of an incident wave plane. The proposed inductor geometry with sawtooth sections demonstrates improved cross-polarization. The analytical results are verified by comparison with 3-D electromagnetic (EM) simulations. As the first proof of concept, W -band optical response is demonstrated through quasioptical characterization at room temperature of an aluminum LEKID array. Moreover, a LEKID array based on bilayer superconducting titanium/aluminum (Ti/Al) thin film is developed for evaluating the performance at millikelvin temperatures. Darkness characterization confirms the high-quality factor of the fabricated detectors and the low-frequency design reliability. In addition, cryogenic optical experiments are performed for spectroscopic and detector sensitivity characterization. The proposed geometry opens the possibility of developing large-format polarimetric cameras based on on-chip LEKID structures for future astronomical experiments.2024info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://zaguan.unizar.es/record/130138reponame:Zaguán. Repositorio Digital de la Universidad de Zaragozainstname:Universidad de ZaragozaInglésinfo:eu-repo/grantAgreement/ES/AEI/PID2019-110610RB-C22info:eu-repo/grantAgreement/ES/CSIC/PTI-001info:eu-repo/grantAgreement/ES/MCIU/SEV-2016-0686info:eu-repo/grantAgreement/ES/MICINN/PID2019-105552RB-C41info:eu-repo/grantAgreement/ES/MICINN/PID2019-105552RB-C44info:eu-repo/grantAgreement/ES/MICINN/RED2022-134839-Tinfo:eu-repo/semantics/openAccessoai:zaguan.unizar.es:1301382026-05-29T13:59:51Z |
| dc.title.none.fl_str_mv |
Optimized cross-polarized LEKIDs for W-band using sawtooth inductors |
| title |
Optimized cross-polarized LEKIDs for W-band using sawtooth inductors |
| spellingShingle |
Optimized cross-polarized LEKIDs for W-band using sawtooth inductors De Ory, Marina C. |
| title_short |
Optimized cross-polarized LEKIDs for W-band using sawtooth inductors |
| title_full |
Optimized cross-polarized LEKIDs for W-band using sawtooth inductors |
| title_fullStr |
Optimized cross-polarized LEKIDs for W-band using sawtooth inductors |
| title_full_unstemmed |
Optimized cross-polarized LEKIDs for W-band using sawtooth inductors |
| title_sort |
Optimized cross-polarized LEKIDs for W-band using sawtooth inductors |
| dc.creator.none.fl_str_mv |
De Ory, Marina C. Rodriguez, David Villa, Enrique De la Fuente, Luisa Aja, Beatriz Rollano, Victor Magaz, María Teresa Pascual, Juan P. Granados, Daniel Artal, Eduardo Gomez, Alicia |
| author |
De Ory, Marina C. |
| author_facet |
De Ory, Marina C. Rodriguez, David Villa, Enrique De la Fuente, Luisa Aja, Beatriz Rollano, Victor Magaz, María Teresa Pascual, Juan P. Granados, Daniel Artal, Eduardo Gomez, Alicia |
| author_role |
author |
| author2 |
Rodriguez, David Villa, Enrique De la Fuente, Luisa Aja, Beatriz Rollano, Victor Magaz, María Teresa Pascual, Juan P. Granados, Daniel Artal, Eduardo Gomez, Alicia |
| author2_role |
author author author author author author author author author author |
| description |
Lumped-element kinetic inductance detectors (LEKIDs) based on sawtooth inductors for W -band are presented in this article. A careful analysis is carried out for the cross-polarization in the inductor geometry, which brings out the absorption of the nondesired E -field component of an incident wave plane. The proposed inductor geometry with sawtooth sections demonstrates improved cross-polarization. The analytical results are verified by comparison with 3-D electromagnetic (EM) simulations. As the first proof of concept, W -band optical response is demonstrated through quasioptical characterization at room temperature of an aluminum LEKID array. Moreover, a LEKID array based on bilayer superconducting titanium/aluminum (Ti/Al) thin film is developed for evaluating the performance at millikelvin temperatures. Darkness characterization confirms the high-quality factor of the fabricated detectors and the low-frequency design reliability. In addition, cryogenic optical experiments are performed for spectroscopic and detector sensitivity characterization. The proposed geometry opens the possibility of developing large-format polarimetric cameras based on on-chip LEKID structures for future astronomical experiments. |
| publishDate |
2024 |
| dc.date.none.fl_str_mv |
2024 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://zaguan.unizar.es/record/130138 |
| url |
http://zaguan.unizar.es/record/130138 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
info:eu-repo/grantAgreement/ES/AEI/PID2019-110610RB-C22 info:eu-repo/grantAgreement/ES/CSIC/PTI-001 info:eu-repo/grantAgreement/ES/MCIU/SEV-2016-0686 info:eu-repo/grantAgreement/ES/MICINN/PID2019-105552RB-C41 info:eu-repo/grantAgreement/ES/MICINN/PID2019-105552RB-C44 info:eu-repo/grantAgreement/ES/MICINN/RED2022-134839-T |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
|
| publisher.none.fl_str_mv |
|
| dc.source.none.fl_str_mv |
reponame:Zaguán. Repositorio Digital de la Universidad de Zaragoza instname:Universidad de Zaragoza |
| instname_str |
Universidad de Zaragoza |
| reponame_str |
Zaguán. Repositorio Digital de la Universidad de Zaragoza |
| collection |
Zaguán. Repositorio Digital de la Universidad de Zaragoza |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869411953758175232 |
| score |
15,300719 |