Evaluating fidelity of CT based 3D models for Zebrafish conductive hearing system

The zebrafish Weberian apparatus is an emerging model for human conductive hearing system. Their Weberian apparatus comprises minute bones and ligamentary links, and conducts sound pressure transmission from the gas bladder to inner ear through four pairs of Weberian ossicles along the vertebral col...

Descripción completa

Detalles Bibliográficos
Autores: Marcé Nogué, Jordi|||0000-0001-9852-7027, Liu, Juan|||0000-0003-0316-7386
Tipo de recurso: artículo
Fecha de publicación:2020
País:España
Institución:Universitat Autònoma de Barcelona
Repositorio:Dipòsit Digital de Documents de la UAB
Idioma:inglés
OAI Identifier:oai:ddd.uab.cat:234453
Acceso en línea:https://ddd.uab.cat/record/234453
https://dx.doi.org/urn:doi:10.1016/j.micron.2020.102874
Access Level:acceso abierto
Palabra clave:Zebrafish
Weberian apparatus
CT imaging
Finite element analysis
Descripción
Sumario:The zebrafish Weberian apparatus is an emerging model for human conductive hearing system. Their Weberian apparatus comprises minute bones and ligamentary links, and conducts sound pressure transmission from the gas bladder to inner ear through four pairs of Weberian ossicles along the vertebral column. We herein present a methodological study using MicroCT to image the Weberian apparatus for biomechanical and morphological analysis. The aim of this work is to evaluate computational models generated from multiple MicroCT scans with different parameters, to identify the most feasible scan combination for practical (minimized scan time) yet accurate (relative to highest resolution) biomechanical simulations. We segmented and created 3D models from CT scan image stacks at 4.64 μm, 5.05 μm, 9.30 μm and 13.08 μm voxel resolutions, respectively. Then, we used geometric morphometrics analysis to quantify inter-model shape differences, as well as a series of finite element modal and harmonic analyses to simulate auditory signal vibrations. Relative to the highest resolution and most accurate model, the Model 9.30 is closest in overall geometry and biomechanical behavior of all lower resolution models. The differences in resolution and quality of the CT substantially affect the segmentation and reconstruction process of the three-dimensional model of the ossicles, and the subsequent analyses. We conclude that scan voxel resolution is a key factor influencing outcomes of biomechanical simulations of delicate and minute structures, especially when studying the harmonic response of minute ossicles connected by ligaments using finite element modeling. Furthermore, contrast variations in CT images as determined by x-ray power and scan speed, also affect fidelity in 3D models and simulation outcomes.