Test-Retest Reliability of Ultrasonographic Measurements from the Rectus Femoris Muscle 1–5 Years after Anterior Cruciate Ligament Reconstruction in the Ipsilateral and Contralateral Legs: An Observational, Case-Control Study

About 40% of traumatic injuries in sports are related to the knee. Of these, 33% require arthroscopic surgery. The rehabilitative ultrasound imaging technique is a simple method to obtain objective real-time results on the state and measurement of the musculoskeletal tissue and its use can represent...

Descripción completa

Detalles Bibliográficos
Autores: Buelga Suarez, Jorge, Alba Martin, Pablo, Cuenca Zaldivar, Juan Nicolas, García Escudero, María, Bierge Sanclemente, Pilar, Almazán Polo, Jaime, Fernandez Carnero, Samuel, Pecos Martín, Daniel
Tipo de recurso: artículo
Fecha de publicación:2022
País:España
Institución:Universidad Católica de Valencia San Vicente Mártir
Repositorio:RIUCV. Repositorio de la Universidad Católica de Valencia San Vicente Mártir
Idioma:inglés
OAI Identifier:oai:riucv.ucv.es:20.500.12466/3281
Acceso en línea:http://hdl.handle.net/20.500.12466/3281
Access Level:acceso abierto
Palabra clave:Knee injuries
Arthroscopy
Ultrasonography
Quadriceps muscle
Muscle contraction
2411.10 Fisiología del Músculo
Descripción
Sumario:About 40% of traumatic injuries in sports are related to the knee. Of these, 33% require arthroscopic surgery. The rehabilitative ultrasound imaging technique is a simple method to obtain objective real-time results on the state and measurement of the musculoskeletal tissue and its use can represent an important change in the process of functional diagnosis and recovery of these injuries. The aim was to quantify the differences in the thickness, muscle contraction time, and muscle relaxation time of the rectus femoris muscle between individuals with knee arthroscopy and healthy individuals and to verify the reliability of the inter-examiner measurements in these ultrasound variables. An observational case-control study with individuals (18–60 years aged) who underwent surgery for anterior cruciate ligament through knee arthroscopy a year or more before. A total of 38 subjects were divided into 2 groups, case and control. Ultrasound measurements were taken of the following outcomes: thickness at rest and contraction, muscle contraction time, and muscle relaxation time of the rectus femoris muscle. Excellent inter-examiner reliability was obtained for all ultrasound measurements (ICC3.3 > 0.90). No significant changes were found in the rate of contraction or rest of the rectus femoris muscle. On the other hand, if significant changes in the thickness of the rectus femoris muscle were found between control and case group. Arthroscopic surgery for anterior cruciate ligament reconstruction does not appear to modify function but does modify the thickness of the rectus femoris muscle on ultrasound examination. Ultrasound appears to be a reliable tool for the study of these measurements in the rectus femoris muscle.