Thermoelectric system applications in buildings: A review of key factors and control methods

A low coefficient of performance (COP) limits the development of thermoelectric (TE) systems in buildings. However, considering their good integration with solar systems and budling structures, there is good application potential for TE systems in buildings. In many previous works, control systems i...

Descripción completa

Detalles Bibliográficos
Autores: He, Z. (Zhineng)|||/items/b5dd3327-fb7a-4d67-95c8-82cd3f35cd2a, Zuazua-Ros, A. (Amaia)|||/items/7e3fc0ae-96df-4fc2-b069-7d17733f10f7, Martín-Gómez, C. (César)|||/items/5b87c1ed-1d69-4d39-bb65-04ca89fd613d
Tipo de recurso: artículo
Fecha de publicación:2023
País:España
Institución:Universidad de Navarra
Repositorio:Dadun. Depósito Académico Digital de la Universidad de Navarra
Idioma:inglés
OAI Identifier:oai:dadun.unav.edu:10171/67345
Acceso en línea:https://hdl.handle.net/10171/67345
Access Level:acceso abierto
Palabra clave:Peltier cell
Electricity
Efficiency
Temperature control
Architecture
id ES_7ef0e405c49e99ea6364c4c39bc4afa5
oai_identifier_str oai:dadun.unav.edu:10171/67345
network_acronym_str ES
network_name_str España
repository_id_str
spelling Thermoelectric system applications in buildings: A review of key factors and control methodsHe, Z. (Zhineng)|||/items/b5dd3327-fb7a-4d67-95c8-82cd3f35cd2aZuazua-Ros, A. (Amaia)|||/items/7e3fc0ae-96df-4fc2-b069-7d17733f10f7Martín-Gómez, C. (César)|||/items/5b87c1ed-1d69-4d39-bb65-04ca89fd613dPeltier cellElectricityEfficiencyTemperature controlArchitectureA low coefficient of performance (COP) limits the development of thermoelectric (TE) systems in buildings. However, considering their good integration with solar systems and budling structures, there is good application potential for TE systems in buildings. In many previous works, control systems indeed help TE systems to improve their performance. Therefore, the objective of this work is to analyze and summarize key factors in the control process and control methods for designing and optimizing the control systems for TE systems in buildings. This work reviews relevant publications from 2000 to 2022 on control applications of TE systems in different fields and groups them into key factors and control methods. The analysis of the key factors indicates the power strength of Peltier cells, the number of working Peltier cells, the temperature difference between the cold and hot sides, and the temperature difference between the object side and the indoor space as significant factors. Additionally, the most relevant control methods for the operating voltage or current are also classified. It is crucial to appropriately adjust these key factors using suitable control methods to achieve improved COP. Regarding the control application of TE systems in buildings, this is an issue that has not been studied with specific attention. Therefore, the analysis of key factors and control methods is meaningful for control systems to improve the performance of TE systems in buildings, especially under dynamic operating conditions of the built environment.ElsevierDadun. Depósito Académico Digital Universidad de Navarra20232023-09-2720232023-01-0120232023-01-01journal articlehttp://purl.org/coar/resource_type/c_6501info:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/10171/67345reponame:Dadun. Depósito Académico Digital de la Universidad de Navarrainstname:Universidad de NavarraInglésengopen accesshttp://purl.org/coar/access_right/c_abf2info:eu-repo/semantics/openAccessoai:dadun.unav.edu:10171/673452026-06-21T12:47:57Z
dc.title.none.fl_str_mv Thermoelectric system applications in buildings: A review of key factors and control methods
title Thermoelectric system applications in buildings: A review of key factors and control methods
spellingShingle Thermoelectric system applications in buildings: A review of key factors and control methods
He, Z. (Zhineng)|||/items/b5dd3327-fb7a-4d67-95c8-82cd3f35cd2a
Peltier cell
Electricity
Efficiency
Temperature control
Architecture
title_short Thermoelectric system applications in buildings: A review of key factors and control methods
title_full Thermoelectric system applications in buildings: A review of key factors and control methods
title_fullStr Thermoelectric system applications in buildings: A review of key factors and control methods
title_full_unstemmed Thermoelectric system applications in buildings: A review of key factors and control methods
title_sort Thermoelectric system applications in buildings: A review of key factors and control methods
dc.creator.none.fl_str_mv He, Z. (Zhineng)|||/items/b5dd3327-fb7a-4d67-95c8-82cd3f35cd2a
Zuazua-Ros, A. (Amaia)|||/items/7e3fc0ae-96df-4fc2-b069-7d17733f10f7
Martín-Gómez, C. (César)|||/items/5b87c1ed-1d69-4d39-bb65-04ca89fd613d
author He, Z. (Zhineng)|||/items/b5dd3327-fb7a-4d67-95c8-82cd3f35cd2a
author_facet He, Z. (Zhineng)|||/items/b5dd3327-fb7a-4d67-95c8-82cd3f35cd2a
Zuazua-Ros, A. (Amaia)|||/items/7e3fc0ae-96df-4fc2-b069-7d17733f10f7
Martín-Gómez, C. (César)|||/items/5b87c1ed-1d69-4d39-bb65-04ca89fd613d
author_role author
author2 Zuazua-Ros, A. (Amaia)|||/items/7e3fc0ae-96df-4fc2-b069-7d17733f10f7
Martín-Gómez, C. (César)|||/items/5b87c1ed-1d69-4d39-bb65-04ca89fd613d
author2_role author
author
dc.contributor.none.fl_str_mv Dadun. Depósito Académico Digital Universidad de Navarra
dc.subject.none.fl_str_mv Peltier cell
Electricity
Efficiency
Temperature control
Architecture
topic Peltier cell
Electricity
Efficiency
Temperature control
Architecture
description A low coefficient of performance (COP) limits the development of thermoelectric (TE) systems in buildings. However, considering their good integration with solar systems and budling structures, there is good application potential for TE systems in buildings. In many previous works, control systems indeed help TE systems to improve their performance. Therefore, the objective of this work is to analyze and summarize key factors in the control process and control methods for designing and optimizing the control systems for TE systems in buildings. This work reviews relevant publications from 2000 to 2022 on control applications of TE systems in different fields and groups them into key factors and control methods. The analysis of the key factors indicates the power strength of Peltier cells, the number of working Peltier cells, the temperature difference between the cold and hot sides, and the temperature difference between the object side and the indoor space as significant factors. Additionally, the most relevant control methods for the operating voltage or current are also classified. It is crucial to appropriately adjust these key factors using suitable control methods to achieve improved COP. Regarding the control application of TE systems in buildings, this is an issue that has not been studied with specific attention. Therefore, the analysis of key factors and control methods is meaningful for control systems to improve the performance of TE systems in buildings, especially under dynamic operating conditions of the built environment.
publishDate 2023
dc.date.none.fl_str_mv 2023
2023-09-27
2023
2023-01-01
2023
2023-01-01
dc.type.none.fl_str_mv journal article
http://purl.org/coar/resource_type/c_6501
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv https://hdl.handle.net/10171/67345
url https://hdl.handle.net/10171/67345
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Dadun. Depósito Académico Digital de la Universidad de Navarra
instname:Universidad de Navarra
instname_str Universidad de Navarra
reponame_str Dadun. Depósito Académico Digital de la Universidad de Navarra
collection Dadun. Depósito Académico Digital de la Universidad de Navarra
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869411787191877632
score 15,300724