Glass-formation and corrosion properties of Fe-Cr-Mo-C-B glassy ribbons with low Cr content

The effect of low amounts of Cr on glass forming ability and corrosion behavior of Fe(65-x)CrxMo14C15B6 (x = 0, 2, 4, 6, 8,10 at.%) ribbons have been studied. It was found that the reduced glass transition temperature (T-rg) do not change significantly with Cr content. The glass forming ability (GFA...

Descripción completa

Detalles Bibliográficos
Autores: Madinehei, Seyed Milad, Bruna Escuer, Pere|||0000-0002-7411-1278, Duarte Correa, María Jazmín, Pineda Soler, Eloi|||0000-0002-1871-3848, Klemm, Julia, Renner, Frank U.
Tipo de recurso: artículo
Fecha de publicación:2014
País:España
Institución:Universitat Politècnica de Catalunya (UPC)
Repositorio:UPCommons. Portal del coneixement obert de la UPC
Idioma:inglés
OAI Identifier:oai:upcommons.upc.edu:2117/26614
Acceso en línea:https://hdl.handle.net/2117/26614
https://dx.doi.org/10.1016/j.jallcom.2013.12.245
Access Level:acceso abierto
Palabra clave:Metallic glasses
Corrosion
Light metal alloys
Fe-based
Amorphous alloys
Glass forming ability
BULK METALLIC GLASSES
FORMING ABILITY
MECHANICAL-PROPERTIES
AMORPHOUS-ALLOYS
RESISTANCE
CRITERION
STEELS
Vidres metàl·lics
Aliatges lleugers
Àrees temàtiques de la UPC::Enginyeria dels materials
Descripción
Sumario:The effect of low amounts of Cr on glass forming ability and corrosion behavior of Fe(65-x)CrxMo14C15B6 (x = 0, 2, 4, 6, 8,10 at.%) ribbons have been studied. It was found that the reduced glass transition temperature (T-rg) do not change significantly with Cr content. The glass forming ability (GFA) of this system is evaluated by the gamma(m), delta and omega parameters and the alloys containing 4 and 6 at.% were found to be the best glass formers in this system. The temperature interval of the supercooled liquid region (Delta T-x) changed with Cr and was enlarged from 35 K at x = 0 to 50 K at x = 4. Corrosion rates measured by immersion tests in H2SO4 decreased with an increase of chromium content in the alloys. The electrochemical measurements indicate that the alloys containing more than 4 at.% of Cr are spontaneously passivated with low current densities in 0.1 N H2SO4 whereas the alloys with Cr content <4 at.% showed transpassive Mo dissolution. In view of these results, the optimal amount of Cr addition in Fe-Mo-C-B amorphous steels is discussed. (C) 2014 Elsevier B.V. All rights reserved.