Screen-printed electrodes for the determination of iridium in drugs
Among the impurities that must be controlled in drugs and pharmaceuticals, metal ions are considered. These metal impurities appear in those products because of their use as catalysts. Although Pharmacopeias recommend ICP based methods for their determination, the use of electroanalytical techniques...
| Autores: | , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión aceptada para publicación |
| Fecha de publicación: | 2018 |
| País: | España |
| Institución: | Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya) |
| Repositorio: | Recercat. Dipósit de la Recerca de Catalunya |
| OAI Identifier: | oai:recercat.cat:2445/140559 |
| Acceso en línea: | https://hdl.handle.net/2445/140559 |
| Access Level: | acceso abierto |
| Palabra clave: | Voltametria Iridi Voltammetry Iridium |
| id |
ES_7e0fb7df7ff103fe2ebb83ff22f18095 |
|---|---|
| oai_identifier_str |
oai:recercat.cat:2445/140559 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Screen-printed electrodes for the determination of iridium in drugsZaguirre, MarcAriño Blasco, CristinaSerrano i Plana, NúriaDíaz Cruz, José ManuelEsteban i Cortada, MiquelVoltametriaIridiVoltammetryIridiumAmong the impurities that must be controlled in drugs and pharmaceuticals, metal ions are considered. These metal impurities appear in those products because of their use as catalysts. Although Pharmacopeias recommend ICP based methods for their determination, the use of electroanalytical techniques can be considered as a sensible, selective and non-expensive alternative for the determination of heavy metal ions in general and metal impurities in particular. In the present work, we propose a differential pulse voltammetric method based on the use of carbon based-screen-printed electrodes (graphite, nanotubes or nanofibers) that allows the determination of iridium in drugs at the concentration limits recommended by official organisms. Carbon screen-printed electrode modified with nanotubes (CNT-SPCE) is the sensor that provided the best LOD and LOQ (0.03 and 0.10 mg L-1 respectively). Then, the proposed method was applied to the voltammetric determination of iridium in spiked drug samples purchased in local chemists using CNT-SPCE.Wiley-VCH2019201920182019info:eu-repo/semantics/articleinfo:eu-repo/semantics/acceptedVersion6 p.application/pdfhttps://hdl.handle.net/2445/140559Articles publicats en revistes (Enginyeria Química i Química Analítica)reponame:Recercat. Dipósit de la Recerca de Catalunyainstname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)InglésVersió postprint del document publicat a: https://doi.org/10.1002/elan.201800502Electroanalysis, 2018, vol. 30, num. 12, p. 2925-2930https://doi.org/10.1002/elan.201800502(c) Wiley-VCH, 2018info:eu-repo/semantics/openAccessoai:recercat.cat:2445/1405592026-05-29T05:05:01Z |
| dc.title.none.fl_str_mv |
Screen-printed electrodes for the determination of iridium in drugs |
| title |
Screen-printed electrodes for the determination of iridium in drugs |
| spellingShingle |
Screen-printed electrodes for the determination of iridium in drugs Zaguirre, Marc Voltametria Iridi Voltammetry Iridium |
| title_short |
Screen-printed electrodes for the determination of iridium in drugs |
| title_full |
Screen-printed electrodes for the determination of iridium in drugs |
| title_fullStr |
Screen-printed electrodes for the determination of iridium in drugs |
| title_full_unstemmed |
Screen-printed electrodes for the determination of iridium in drugs |
| title_sort |
Screen-printed electrodes for the determination of iridium in drugs |
| dc.creator.none.fl_str_mv |
Zaguirre, Marc Ariño Blasco, Cristina Serrano i Plana, Núria Díaz Cruz, José Manuel Esteban i Cortada, Miquel |
| author |
Zaguirre, Marc |
| author_facet |
Zaguirre, Marc Ariño Blasco, Cristina Serrano i Plana, Núria Díaz Cruz, José Manuel Esteban i Cortada, Miquel |
| author_role |
author |
| author2 |
Ariño Blasco, Cristina Serrano i Plana, Núria Díaz Cruz, José Manuel Esteban i Cortada, Miquel |
| author2_role |
author author author author |
| dc.subject.none.fl_str_mv |
Voltametria Iridi Voltammetry Iridium |
| topic |
Voltametria Iridi Voltammetry Iridium |
| description |
Among the impurities that must be controlled in drugs and pharmaceuticals, metal ions are considered. These metal impurities appear in those products because of their use as catalysts. Although Pharmacopeias recommend ICP based methods for their determination, the use of electroanalytical techniques can be considered as a sensible, selective and non-expensive alternative for the determination of heavy metal ions in general and metal impurities in particular. In the present work, we propose a differential pulse voltammetric method based on the use of carbon based-screen-printed electrodes (graphite, nanotubes or nanofibers) that allows the determination of iridium in drugs at the concentration limits recommended by official organisms. Carbon screen-printed electrode modified with nanotubes (CNT-SPCE) is the sensor that provided the best LOD and LOQ (0.03 and 0.10 mg L-1 respectively). Then, the proposed method was applied to the voltammetric determination of iridium in spiked drug samples purchased in local chemists using CNT-SPCE. |
| publishDate |
2018 |
| dc.date.none.fl_str_mv |
2018 2019 2019 2019 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/acceptedVersion |
| format |
article |
| status_str |
acceptedVersion |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2445/140559 |
| url |
https://hdl.handle.net/2445/140559 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
Versió postprint del document publicat a: https://doi.org/10.1002/elan.201800502 Electroanalysis, 2018, vol. 30, num. 12, p. 2925-2930 https://doi.org/10.1002/elan.201800502 |
| dc.rights.none.fl_str_mv |
(c) Wiley-VCH, 2018 info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
(c) Wiley-VCH, 2018 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
6 p. application/pdf |
| dc.publisher.none.fl_str_mv |
Wiley-VCH |
| publisher.none.fl_str_mv |
Wiley-VCH |
| dc.source.none.fl_str_mv |
Articles publicats en revistes (Enginyeria Química i Química Analítica) reponame:Recercat. Dipósit de la Recerca de Catalunya instname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya) |
| instname_str |
Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya) |
| reponame_str |
Recercat. Dipósit de la Recerca de Catalunya |
| collection |
Recercat. Dipósit de la Recerca de Catalunya |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869411709368664064 |
| score |
15.812429 |