Repeatability and reproducibility of retinal and choroidal thickness measurements in diabetic macular edema using swept-source optical coherence tomography
Purpose To evaluate the repeatability and reproducibility of retinal and choroidal thickness measured with Swept source Optical Coherence Tomography (SS-OCT) in eyes with Diabetic Macular Edema (DME). Methods 42 DME eyes were imaged using SS-OCT standard Macular scanning protocols. Retinal and choro...
| Autores: | , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2018 |
| País: | España |
| Institución: | Universidad de Barcelona |
| Repositorio: | Dipòsit Digital de la UB |
| OAI Identifier: | oai:diposit.ub.edu:2445/149223 |
| Acceso en línea: | https://hdl.handle.net/2445/149223 |
| Access Level: | acceso abierto |
| Palabra clave: | Retinopatia diabètica Tomografia de coherència òptica Diabetic retinopathy Optical coherence tomography |
| id |
ES_7d00c217aa799eb8b618dc6d69b222cf |
|---|---|
| oai_identifier_str |
oai:diposit.ub.edu:2445/149223 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Repeatability and reproducibility of retinal and choroidal thickness measurements in diabetic macular edema using swept-source optical coherence tomographySala Puigdollers, AnnaFigueras Roca, MarcHereu, MireiaHernandez, TeresaMorato, MontseAdán Civera, AlfredoZarranz Ventura, JavierRetinopatia diabèticaTomografia de coherència òpticaDiabetic retinopathyOptical coherence tomographyPurpose To evaluate the repeatability and reproducibility of retinal and choroidal thickness measured with Swept source Optical Coherence Tomography (SS-OCT) in eyes with Diabetic Macular Edema (DME). Methods 42 DME eyes were imaged using SS-OCT standard Macular scanning protocols. Retinal and choroidal thickness were measured in the Total macular circle (TMC) and foveal central subfield (FCS) using device-integrated specific software. The coefficient of repeatability (CR) and intraclass correlation coefficient (ICC) were determined as a measure of repeatability and relative reliability within graders. Reproducibility was assessed using Bland-Altman plots and 95% limits of agreement (LoA) were determined as a measure of interobserver variability. Results Intragrader CR of retinal and choroidal thickness were 8.37 and 12.20 microns for TMC and 22.24 and 32.40 microns for FCS, and intergrader 95% LoA were 7.37 +/- 8.69 and -27.2 +/- 27.71 microns for TMC and -34.21 +/- 41.93 and -30.46 +/- 24.84 for FCS, respectively. Retinal and choroidal thickness showed very good intraobserver reliability for both TMC and FCS (ICC 0.99, LoA 0.98 +/- 0.99 in all cases). Intraobserver and interobserver variability for retinal and choroidal thickness was not significantly different for TMC (p = 0.98 and p = 0.90, p = 0.98 and p = 0.91) or FCS (p = 0.97 and p = 0.85, p = 0.78 and p = 0.73), respectively. Conclusions Retinal and choroidal thickness in DME eyes can be quantified with good reliability, repeatability and reproducibility using new OCT devices that incorporate swept source technology. The technical advantages of this technology may provide new insights in the understanding of the choroidal changes related with DME.Public Library of Science (PLoS)2018info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://hdl.handle.net/2445/149223Articles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)reponame:Dipòsit Digital de la UBinstname:Universidad de BarcelonaInglésReproducció del document publicat a: https://doi.org/10.1371/journal.pone.0200819PLoS One, 2018, vol. 13, num. 7, p. e0200819https://doi.org/10.1371/journal.pone.0200819cc-by (c) Sala Puigdollers, Anna et al., 2018http://creativecommons.org/licenses/by/3.0/esinfo:eu-repo/semantics/openAccessoai:diposit.ub.edu:2445/1492232026-05-27T06:46:51Z |
| dc.title.none.fl_str_mv |
Repeatability and reproducibility of retinal and choroidal thickness measurements in diabetic macular edema using swept-source optical coherence tomography |
| title |
Repeatability and reproducibility of retinal and choroidal thickness measurements in diabetic macular edema using swept-source optical coherence tomography |
| spellingShingle |
Repeatability and reproducibility of retinal and choroidal thickness measurements in diabetic macular edema using swept-source optical coherence tomography Sala Puigdollers, Anna Retinopatia diabètica Tomografia de coherència òptica Diabetic retinopathy Optical coherence tomography |
| title_short |
Repeatability and reproducibility of retinal and choroidal thickness measurements in diabetic macular edema using swept-source optical coherence tomography |
| title_full |
Repeatability and reproducibility of retinal and choroidal thickness measurements in diabetic macular edema using swept-source optical coherence tomography |
| title_fullStr |
Repeatability and reproducibility of retinal and choroidal thickness measurements in diabetic macular edema using swept-source optical coherence tomography |
| title_full_unstemmed |
Repeatability and reproducibility of retinal and choroidal thickness measurements in diabetic macular edema using swept-source optical coherence tomography |
| title_sort |
Repeatability and reproducibility of retinal and choroidal thickness measurements in diabetic macular edema using swept-source optical coherence tomography |
| dc.creator.none.fl_str_mv |
Sala Puigdollers, Anna Figueras Roca, Marc Hereu, Mireia Hernandez, Teresa Morato, Montse Adán Civera, Alfredo Zarranz Ventura, Javier |
| author |
Sala Puigdollers, Anna |
| author_facet |
Sala Puigdollers, Anna Figueras Roca, Marc Hereu, Mireia Hernandez, Teresa Morato, Montse Adán Civera, Alfredo Zarranz Ventura, Javier |
| author_role |
author |
| author2 |
Figueras Roca, Marc Hereu, Mireia Hernandez, Teresa Morato, Montse Adán Civera, Alfredo Zarranz Ventura, Javier |
| author2_role |
author author author author author author |
| dc.subject.none.fl_str_mv |
Retinopatia diabètica Tomografia de coherència òptica Diabetic retinopathy Optical coherence tomography |
| topic |
Retinopatia diabètica Tomografia de coherència òptica Diabetic retinopathy Optical coherence tomography |
| description |
Purpose To evaluate the repeatability and reproducibility of retinal and choroidal thickness measured with Swept source Optical Coherence Tomography (SS-OCT) in eyes with Diabetic Macular Edema (DME). Methods 42 DME eyes were imaged using SS-OCT standard Macular scanning protocols. Retinal and choroidal thickness were measured in the Total macular circle (TMC) and foveal central subfield (FCS) using device-integrated specific software. The coefficient of repeatability (CR) and intraclass correlation coefficient (ICC) were determined as a measure of repeatability and relative reliability within graders. Reproducibility was assessed using Bland-Altman plots and 95% limits of agreement (LoA) were determined as a measure of interobserver variability. Results Intragrader CR of retinal and choroidal thickness were 8.37 and 12.20 microns for TMC and 22.24 and 32.40 microns for FCS, and intergrader 95% LoA were 7.37 +/- 8.69 and -27.2 +/- 27.71 microns for TMC and -34.21 +/- 41.93 and -30.46 +/- 24.84 for FCS, respectively. Retinal and choroidal thickness showed very good intraobserver reliability for both TMC and FCS (ICC 0.99, LoA 0.98 +/- 0.99 in all cases). Intraobserver and interobserver variability for retinal and choroidal thickness was not significantly different for TMC (p = 0.98 and p = 0.90, p = 0.98 and p = 0.91) or FCS (p = 0.97 and p = 0.85, p = 0.78 and p = 0.73), respectively. Conclusions Retinal and choroidal thickness in DME eyes can be quantified with good reliability, repeatability and reproducibility using new OCT devices that incorporate swept source technology. The technical advantages of this technology may provide new insights in the understanding of the choroidal changes related with DME. |
| publishDate |
2018 |
| dc.date.none.fl_str_mv |
2018 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2445/149223 |
| url |
https://hdl.handle.net/2445/149223 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
Reproducció del document publicat a: https://doi.org/10.1371/journal.pone.0200819 PLoS One, 2018, vol. 13, num. 7, p. e0200819 https://doi.org/10.1371/journal.pone.0200819 |
| dc.rights.none.fl_str_mv |
cc-by (c) Sala Puigdollers, Anna et al., 2018 http://creativecommons.org/licenses/by/3.0/es info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
cc-by (c) Sala Puigdollers, Anna et al., 2018 http://creativecommons.org/licenses/by/3.0/es |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Public Library of Science (PLoS) |
| publisher.none.fl_str_mv |
Public Library of Science (PLoS) |
| dc.source.none.fl_str_mv |
Articles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques) reponame:Dipòsit Digital de la UB instname:Universidad de Barcelona |
| instname_str |
Universidad de Barcelona |
| reponame_str |
Dipòsit Digital de la UB |
| collection |
Dipòsit Digital de la UB |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869411631171108864 |
| score |
15.300719 |