Continuous Glucose Monitoring in Resource-Constrained Settings for Hypoglycaemia Detection: Looking at the Problem from the Other Side of the Coin
The appearance, over a decade ago, of continuous glucose monitoring (CGM) devices has triggered a patient-centred revolution in the control and management of diabetes mellitus and other metabolic conditions, improving the patient’s glycaemic control and quality of life. Such devices, the use of whic...
| Autores: | , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2018 |
| País: | España |
| Institución: | Universidad de Barcelona |
| Repositorio: | Dipòsit Digital de la UB |
| OAI Identifier: | oai:diposit.ub.edu:2445/122198 |
| Acceso en línea: | https://hdl.handle.net/2445/122198 |
| Access Level: | acceso abierto |
| Palabra clave: | Hipoglucèmia Glucosa Hypoglycemia Glucose |
| id |
ES_7cb540d6a30ced716cc5dacdeb5ec2c3 |
|---|---|
| oai_identifier_str |
oai:diposit.ub.edu:2445/122198 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Continuous Glucose Monitoring in Resource-Constrained Settings for Hypoglycaemia Detection: Looking at the Problem from the Other Side of the CoinBila, RubaoVaro, RosauroMadrid, LolaSitoe, AntonioBassat Orellana, QuiqueHipoglucèmiaGlucosaHypoglycemiaGlucoseThe appearance, over a decade ago, of continuous glucose monitoring (CGM) devices has triggered a patient-centred revolution in the control and management of diabetes mellitus and other metabolic conditions, improving the patient’s glycaemic control and quality of life. Such devices, the use of which remains typically restricted to high-income countries on account of their elevated costs, at present show very limited implantation in resource-constrained settings, where many other urgent health priorities beyond diabetes prevention and management still need to be resolved. In this commentary, we argue that such devices could have an additional utility in low-income settings, whereby they could be selectively used among severely ill children admitted to hospital for closer monitoring of paediatric hypoglycaemia, a life-threatening condition often complicating severe cases of malaria, malnutrition, and other common paediatric conditions.MDPI2018info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://hdl.handle.net/2445/122198Articles publicats en revistes (ISGlobal)reponame:Dipòsit Digital de la UBinstname:Universidad de BarcelonaInglésReproducció del document publicat a: http://dx.doi.org/10.3390/bios8020043Biosensors, 2018, vol. 8, num. 2, p. e43http://dx.doi.org/10.3390/bios8020043cc by (c) Bila et al., 2018http://creativecommons.org/licenses/by/3.0/es/info:eu-repo/semantics/openAccessoai:diposit.ub.edu:2445/1221982026-05-27T06:46:51Z |
| dc.title.none.fl_str_mv |
Continuous Glucose Monitoring in Resource-Constrained Settings for Hypoglycaemia Detection: Looking at the Problem from the Other Side of the Coin |
| title |
Continuous Glucose Monitoring in Resource-Constrained Settings for Hypoglycaemia Detection: Looking at the Problem from the Other Side of the Coin |
| spellingShingle |
Continuous Glucose Monitoring in Resource-Constrained Settings for Hypoglycaemia Detection: Looking at the Problem from the Other Side of the Coin Bila, Rubao Hipoglucèmia Glucosa Hypoglycemia Glucose |
| title_short |
Continuous Glucose Monitoring in Resource-Constrained Settings for Hypoglycaemia Detection: Looking at the Problem from the Other Side of the Coin |
| title_full |
Continuous Glucose Monitoring in Resource-Constrained Settings for Hypoglycaemia Detection: Looking at the Problem from the Other Side of the Coin |
| title_fullStr |
Continuous Glucose Monitoring in Resource-Constrained Settings for Hypoglycaemia Detection: Looking at the Problem from the Other Side of the Coin |
| title_full_unstemmed |
Continuous Glucose Monitoring in Resource-Constrained Settings for Hypoglycaemia Detection: Looking at the Problem from the Other Side of the Coin |
| title_sort |
Continuous Glucose Monitoring in Resource-Constrained Settings for Hypoglycaemia Detection: Looking at the Problem from the Other Side of the Coin |
| dc.creator.none.fl_str_mv |
Bila, Rubao Varo, Rosauro Madrid, Lola Sitoe, Antonio Bassat Orellana, Quique |
| author |
Bila, Rubao |
| author_facet |
Bila, Rubao Varo, Rosauro Madrid, Lola Sitoe, Antonio Bassat Orellana, Quique |
| author_role |
author |
| author2 |
Varo, Rosauro Madrid, Lola Sitoe, Antonio Bassat Orellana, Quique |
| author2_role |
author author author author |
| dc.subject.none.fl_str_mv |
Hipoglucèmia Glucosa Hypoglycemia Glucose |
| topic |
Hipoglucèmia Glucosa Hypoglycemia Glucose |
| description |
The appearance, over a decade ago, of continuous glucose monitoring (CGM) devices has triggered a patient-centred revolution in the control and management of diabetes mellitus and other metabolic conditions, improving the patient’s glycaemic control and quality of life. Such devices, the use of which remains typically restricted to high-income countries on account of their elevated costs, at present show very limited implantation in resource-constrained settings, where many other urgent health priorities beyond diabetes prevention and management still need to be resolved. In this commentary, we argue that such devices could have an additional utility in low-income settings, whereby they could be selectively used among severely ill children admitted to hospital for closer monitoring of paediatric hypoglycaemia, a life-threatening condition often complicating severe cases of malaria, malnutrition, and other common paediatric conditions. |
| publishDate |
2018 |
| dc.date.none.fl_str_mv |
2018 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2445/122198 |
| url |
https://hdl.handle.net/2445/122198 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
Reproducció del document publicat a: http://dx.doi.org/10.3390/bios8020043 Biosensors, 2018, vol. 8, num. 2, p. e43 http://dx.doi.org/10.3390/bios8020043 |
| dc.rights.none.fl_str_mv |
cc by (c) Bila et al., 2018 http://creativecommons.org/licenses/by/3.0/es/ info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
cc by (c) Bila et al., 2018 http://creativecommons.org/licenses/by/3.0/es/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
MDPI |
| publisher.none.fl_str_mv |
MDPI |
| dc.source.none.fl_str_mv |
Articles publicats en revistes (ISGlobal) reponame:Dipòsit Digital de la UB instname:Universidad de Barcelona |
| instname_str |
Universidad de Barcelona |
| reponame_str |
Dipòsit Digital de la UB |
| collection |
Dipòsit Digital de la UB |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869411610392526848 |
| score |
15,301603 |