Time in Range Analysis in Automated Insulin Delivery Era: Should Day and Nighttime Targets be the Same?

Introduction: Hybrid closed-loop systems (HCLS) use has shown that time in range (TIR) tends to improve more during the nighttime than during the day. This study aims to compare the conventional TIR, currently accepted as 70 to 180 mg/dL, with a proposed recalculated time in range (RTIR) considering...

Descripción completa

Detalles Bibliográficos
Autores: Maia, A, Andujar, DS, Yuste, C, Albert, L, Vilaverde, J, Cardoso, MH, Rigla, M
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2024
País:España
Institución:Institut d'Investigació i Innovació Parc Taulí (I3PT)
Repositorio:r-I3PT. Repositorio Institucional Producción Científica del Institut d'Investigació i Innovació Parc Taulí
OAI Identifier:oai:i3pt.fundanetsuite.com:p4589
Acceso en línea:https://i3pt.portalinvestigacion.com/publicaciones/4589
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85188298370&doi=10.1177%2f19322968241236456&partnerID=40&md5=75d8813cfcdee8ee069375bfd4ed3311
Access Level:acceso abierto
Palabra clave:type 1 diabetes mellitus
automated insulin delivery
hybrid closed-loop systems
continuous glucose monitoring
time in range
Descripción
Sumario:Introduction: Hybrid closed-loop systems (HCLS) use has shown that time in range (TIR) tends to improve more during the nighttime than during the day. This study aims to compare the conventional TIR, currently accepted as 70 to 180 mg/dL, with a proposed recalculated time in range (RTIR) considering a tighter glucose target of 70 to 140 mg/dL for the nighttime fasting period in T1DM patients under HCLS.Methods: We conducted a retrospective study that included adults patients receiving treatment with Tandem t:slim X2 Control-IQ. Daytime TIR was characterized as glucose values between 70 and 180 mg/dL during the 07:01 to 23:59 time frame. Nighttime fasting TIR was specified as glucose values from 70 to 140 mg/dL between 00:00 and 07:00. The combination of the daytime and nighttime fasting glucose targets results in an RTIR, which was compared with the conventional TIR for each patient. The 14 days Dexcom G6 CGM data were downloaded from Tidepool platform and analyzed.Results: We included 22 patients with a mean age of 49.7 years and diabetes duration of 24.7 years, who had been using automatic insulin delivery (AID) HCLS for a median of 305.3 days. We verified a mean conventional TIR of 68.7% vs a mean RTIR of 60.3%, with a mean percentage difference between these two metrics of -8.4%. A significant decrease in conventional TIR was verified when tighter glucose targets were considered during the nighttime period. No significant correlation was found between the percentage difference values and RTIR, even among the group of patients with the lowest conventional TIR.Conclusions: Currently, meeting the conventional TIR metrics may fall short of achieving an ideal level of glycemic control. An individualized strategy should be adopted until further data become available for a precise definition of optimal glucose targets.