Laccase-luminol chemiluminescence system: an investigation of substrate inhibition

Chemiluminescence (CL) reactions are widely used for the detection and quantification of many types of analytes. Laccase has previously been proposed in CL reactions; however, its light emission behaviour has not been characterized. This study was conducted to characterize the laccase-luminol system...

Descripción completa

Detalles Bibliográficos
Autores: Sánchez Trasviña, Calef, Galindo Estrada, José Daniel, Tinoco Valencia, Raunel, Serrano Carreón, Leobardo, Rito Palomares, Marco, Willson, Richard C, Mayolo Deloisa, Karla P.
Tipo de recurso: artículo
Estado:Versión aceptada para publicación
Fecha de publicación:2023
País:España
Institución:Consejo Superior de Investigaciones Científicas (CSIC)
Repositorio:DIGITAL.CSIC. Repositorio Institucional del CSIC
OAI Identifier:oai:digital.csic.es:10261/329772
Acceso en línea:http://hdl.handle.net/10261/329772
https://api.elsevier.com/content/abstract/scopus_id/85148459481
Access Level:acceso abierto
Palabra clave:Biosensor
Chemiluminescence
Laccase
Luminol
Substrate inhibition
Descripción
Sumario:Chemiluminescence (CL) reactions are widely used for the detection and quantification of many types of analytes. Laccase has previously been proposed in CL reactions; however, its light emission behaviour has not been characterized. This study was conducted to characterize the laccase-luminol system, determine its kinetic parameters, and analyze the effects of protein and OH- concentration on the CL signal. Laccase from Coriolopsis gallica was combined with different concentrations of luminol (125 nM to 4 mM), and the enzyme kinetics were evaluated using diverse kinetic models. The laccase-luminol system was able to produce CL without an intermediate molecule, but it exhibited substrate-inhibition behaviour. A two-site random model was used and suggested that when the first luminol molecule was bound to the active site, laccase affinity for the second luminol molecule was increased. This inhibition effect could be avoided using a low luminol concentration. At 5 μM luminol concentration, 1 mg/ml (0.13 U) laccase is needed to achieve nearly 90% of the maximum CL signal, suggesting that the available luminol could not bind to all active sites. Furthermore, the concentration of NaOH negatively affected the CL signal. The laccase-luminol system represents an alternative to existing CL systems, with potential uses in molecular detection and quantification.