Prevalence and consequences of patient-ventilator interactions in a cohort of home-ventilated restrictive and neuromuscular patients: a multicentre study
Aims Analysis of patient-ventilator interactions in patients on chronic home mechanical ventilation can be time consuming, and the consequences of individual interaction on pulmonary gas exchange are not well understood. The objective was to analyse the relationship between interactions and nocturna...
| Autores: | , , , , , , , , , , |
|---|---|
| Formato: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2025 |
| País: | España |
| Recursos: | Institut d'Investigació i Innovació Parc Taulí (I3PT) |
| Repositorio: | r-I3PT. Repositorio Institucional Producción Científica del Institut d'Investigació i Innovació Parc Taulí |
| OAI Identifier: | oai:i3pt.fundanetsuite.com:p6694 |
| Acesso em linha: | https://i3pt.portalinvestigacion.com/publicaciones/6694 https://www.scopus.com/inward/record.uri?eid=2-s2.0-105022255624&doi=10.1183%2F23120541.01388-2024&partnerID=40&md5=45956261c404f6297766a057cd08e933 |
| Access Level: | acceso abierto |
| Palavra-chave: | adult aged anthropometry arterial gas Article artificial ventilation breathing rate clinical article cohort analysis controlled study cross-sectional study diagnostic test accuracy study female heart rate human male multicenter study neuromuscular disease neuromuscular patient obesity hypoventilation syndrome observational study oxygen saturation patient patient-ventilator asynchrony Pittsburgh Sleep Quality Index prevalence pulse oximetry sensitivity and specificity sleep quality tidal volume ventilated patient |
| Resumo: | Aims Analysis of patient-ventilator interactions in patients on chronic home mechanical ventilation can be time consuming, and the consequences of individual interaction on pulmonary gas exchange are not well understood. The objective was to analyse the relationship between interactions and nocturnal oximetry and arterial blood gases. Methods A cross-sectional study was carried out in restrictive and neuromuscular patients who underwent respiratory polygraphy with a system that allowed interactions to be correlated with mean saturation in 5-min periods. Unintentional leaks, periodic decreases in flow and primary patient-ventilator asynchronies were analysed. Each interaction was correlated with mean oxygen saturation measured by pulse oximetry (S<INF>pO<INF>2</INF></INF>) and baseline arterial blood gases obtained at the recruitment visit, and the 5-min S<INF>pO<INF>2</INF></INF> analysis was individualised for each patient based on their mean +/- sd S<INF>pO<INF>2</INF></INF> during polygraphy. Results 40 patients were included. There was a correlation between interactions and mean S<INF>pO<INF>2</INF></INF> in periods with mean accidental leak >20 L<middle dot>min-1 (ANOVA test). After exclusion of periods with leakage above this threshold, a relationship was documented between periodic decreases in flow and asynchronies with mean S<INF>pO<INF>2</INF></INF> in 5-min periods. However, there was no relationship between patient-ventilator interactions and baseline arterial blood gases at recruitment. Conclusion The presence of interactions was associated with a decrease in mean S<INF>pO<INF>2</INF></INF> when 5-min recordings are analysed. Therefore, it seems advisable to systematically detect and correct patient-ventilator interactions in home mechanical ventilated patients. |
|---|