An experimental model to mimic the mechanical behavior of a scaffold in a cartilage defect

[EN] Abstract The main purpose of this thesis is the design and characterization of an experimental articular cartilage model. The in vitro model is composed of a macro and micro- porous Polycaprolactone scaffold with a Poly(Vinyl Alcohol) filling. The scaffold/hydrogel construct has been subjected...

Descripción completa

Detalles Bibliográficos
Autor: Vikingsson, Line Karina Alva
Tipo de recurso: tesis doctoral
Fecha de publicación:2015
País:España
Institución:Universitat Politècnica de València (UPV)
Repositorio:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Idioma:inglés
OAI Identifier:oai:riunet.upv.es:10251/53912
Acceso en línea:https://riunet.upv.es/handle/10251/53912
Access Level:acceso abierto
Palabra clave:Scaffolds, biomaterials, tissue engineering
MAQUINAS Y MOTORES TERMICOS
id ES_7998f5fa283358dbc1913ab90dec7ce2
oai_identifier_str oai:riunet.upv.es:10251/53912
network_acronym_str ES
network_name_str España
repository_id_str
dc.title.none.fl_str_mv An experimental model to mimic the mechanical behavior of a scaffold in a cartilage defect
title An experimental model to mimic the mechanical behavior of a scaffold in a cartilage defect
spellingShingle An experimental model to mimic the mechanical behavior of a scaffold in a cartilage defect
Vikingsson, Line Karina Alva
Scaffolds, biomaterials, tissue engineering
MAQUINAS Y MOTORES TERMICOS
title_short An experimental model to mimic the mechanical behavior of a scaffold in a cartilage defect
title_full An experimental model to mimic the mechanical behavior of a scaffold in a cartilage defect
title_fullStr An experimental model to mimic the mechanical behavior of a scaffold in a cartilage defect
title_full_unstemmed An experimental model to mimic the mechanical behavior of a scaffold in a cartilage defect
title_sort An experimental model to mimic the mechanical behavior of a scaffold in a cartilage defect
dc.creator.none.fl_str_mv Vikingsson, Line Karina Alva
author Vikingsson, Line Karina Alva
author_facet Vikingsson, Line Karina Alva
author_role author
dc.contributor.none.fl_str_mv Gallego Ferrer, Gloria
Gómez Ribelles, José Luís
Departamento de Termodinámica Aplicada
Centro de Biomateriales e Ingeniería Tisular
Escuela Técnica Superior de Ingeniería Industrial
Repositorio Institucional de la Universitat Politècnica de València Riunet
dc.subject.none.fl_str_mv Scaffolds, biomaterials, tissue engineering
MAQUINAS Y MOTORES TERMICOS
topic Scaffolds, biomaterials, tissue engineering
MAQUINAS Y MOTORES TERMICOS
description [EN] Abstract The main purpose of this thesis is the design and characterization of an experimental articular cartilage model. The in vitro model is composed of a macro and micro- porous Polycaprolactone scaffold with a Poly(Vinyl Alcohol) filling. The scaffold/hydrogel construct has been subjected to repeating number of freezing and thawing cycles in order to crosslink the hydrogel inside the scaffold's pores. The Poly(Vinyl Alcohol) resembles the growing cartilaginous tissue inside the scaffolds pores, as it gets denser and stiffer for each cycle of freezing and thawing. The in vitro model allows studying a variety of characteristics of the scaffold and hydrogel, revealing interesting features. The importance of water flow on the mechanical properties is studied, so as the influence of micro-porosity. It can be seen that the mechanical properties of the porous scaffolds are influenced in distinct ways by the hydrogel density and micro-porosity of the scaffold. The permeability of the scaffolds is studied and is seen independent of crosslinking density of the hydrogel inside the porous scaffolds. The experimental cartilage model has also been applied on a macro porous acrylic scaffold. The results show that the water has different effect on the mechanical properties, for macro, or macro and micro-porous scaffolds. The in vitro cartilage model has elastic modulus, aggregate modulus and permeability values in the same order as human articular cartilage. The model is useful to predict the mechanical behavior of porous scaffolds in vivo. A scaffold implant device for animal studies has been designed based on a previous patent of the research group, and implanted in two different in vivo trials in sheep. The results show that the fixation and anchoring to the subchondral bone improve the tissue repair and diminish alterations in the subchondral bone. ¿
publishDate 2015
dc.date.none.fl_str_mv 2015
2015-07-29
2015
2015-07-14
dc.type.none.fl_str_mv doctoral thesis
http://purl.org/coar/resource_type/c_db06
AM
http://purl.org/coar/version/c_ab4af688f83e57aa
dc.type.openaire.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
dc.identifier.none.fl_str_mv https://riunet.upv.es/handle/10251/53912
url https://riunet.upv.es/handle/10251/53912
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
Reserva de todos los derechos
http://rightsstatements.org/vocab/InC/1.0/
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
Reserva de todos los derechos
http://rightsstatements.org/vocab/InC/1.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/msword
application/msword
dc.publisher.none.fl_str_mv Universitat Politècnica de València
publisher.none.fl_str_mv Universitat Politècnica de València
dc.source.none.fl_str_mv reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
instname:Universitat Politècnica de València (UPV)
instname_str Universitat Politècnica de València (UPV)
reponame_str RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
collection RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869411361234092032
spelling An experimental model to mimic the mechanical behavior of a scaffold in a cartilage defectVikingsson, Line Karina AlvaScaffolds, biomaterials, tissue engineeringMAQUINAS Y MOTORES TERMICOS[EN] Abstract The main purpose of this thesis is the design and characterization of an experimental articular cartilage model. The in vitro model is composed of a macro and micro- porous Polycaprolactone scaffold with a Poly(Vinyl Alcohol) filling. The scaffold/hydrogel construct has been subjected to repeating number of freezing and thawing cycles in order to crosslink the hydrogel inside the scaffold's pores. The Poly(Vinyl Alcohol) resembles the growing cartilaginous tissue inside the scaffolds pores, as it gets denser and stiffer for each cycle of freezing and thawing. The in vitro model allows studying a variety of characteristics of the scaffold and hydrogel, revealing interesting features. The importance of water flow on the mechanical properties is studied, so as the influence of micro-porosity. It can be seen that the mechanical properties of the porous scaffolds are influenced in distinct ways by the hydrogel density and micro-porosity of the scaffold. The permeability of the scaffolds is studied and is seen independent of crosslinking density of the hydrogel inside the porous scaffolds. The experimental cartilage model has also been applied on a macro porous acrylic scaffold. The results show that the water has different effect on the mechanical properties, for macro, or macro and micro-porous scaffolds. The in vitro cartilage model has elastic modulus, aggregate modulus and permeability values in the same order as human articular cartilage. The model is useful to predict the mechanical behavior of porous scaffolds in vivo. A scaffold implant device for animal studies has been designed based on a previous patent of the research group, and implanted in two different in vivo trials in sheep. The results show that the fixation and anchoring to the subchondral bone improve the tissue repair and diminish alterations in the subchondral bone. ¿[ES] Resumen El objetivo principal de esta tesis doctoral es el diseño y caracterización de un modelo de cartílago articular experimental. El modelo in vitro se compone de un scaffold micro- y macroporoso de Policaprolactona con un relleno de Poli(Vinil Alcohol). El constructo scaffold/hidrogel ha sido sometido a ciclos consecutivos de congelación y descongelación con objeto de entrecruzar el hidrogel dentro de los poros del scaffold. El Poli(Vinil Alcohol) mimetiza al tejido de cartílago que se regenerará en los poros, ya que en cada ciclo de congelación y descongelación se vuelve más denso y duro. El modelo in vitro permite estudiar una gran variedad de características del scaffold e hidrogel, revelando fenómenos interesantes para la ingeniería tisular. Se ha estudiado la importancia del flujo de agua a través del scaffold en las propiedades mecánicas, así como la influencia de la microporosidad. Se ha podido constatar que la densidad del hidrogel y la microporosidad influyen de distinta forma en las propiedades mecánicas de los scaffolds porosos. Se ha estudiado la permeabilidad de los scaffolds, que ha resultado ser independiente de la densidad de entrecruzamiento del hidrogel dentro de sus poros. El modelo experimental de cartílago se ha aplicado también a un scaffold macroporoso acrílico. Los resultados muestran que el agua tiene un efecto distinto en las propiedades mecánicas de los scaffolds macroporosos y en los micro- macroporosos. El modelo de cartílago in vitro tiene valores del modulo elástico, módulo agregado y permeabilidad que son del mismo orden de magnitud que los del cartílago articular humano. El modelo permite predecir el comportamiento mecánico in vivo de scaffolds porosos. Se ha diseñado un dispositivo de implante de scaffold para experimentos en animales basado en una patente del grupo de investigación, que ha sido implantado en dos ensayos in vivo diferentes en ovejas. Los resultados muestran que la fijación y anclaje al hueso subcondral tiene un gran papel en la reparación del tejido.[CA] Resum L'objectiu principal d'aquesta tesi doctoral és el disseny i caracterització d'un model de cartílag articular experimental. El model in vitro es compon d'un scaffold micro- i macroporós de Policaprolactona amb un farciment de Poli(Vinil Alcohol). El constructe scaffold/hidrogel ha estat sotmès a cicles consecutius de congelació i descongelació amb l'objectiu d'entrecreuar l'hidrogel dins del porus del scaffold. El Poli(Vinil Alcohol) mimetitza al teixit de cartílag que es regenerarà en el porus, ja que en cada cicle de congelació i descongelació es torna més dens i dur. El model in vitro permet estudiar una gran varietat de característiques del scaffold i hidrogel, posant de manifest fenòmens interessants per a l'enginyeria tissular. S'ha estudiat la importància del flux d'aigua a través del scaffold en les propietats mecàniques, així com la influència de la microporositat. S'ha pogut constatar que la densitat de l'hidrogel i la microporositat influeixen de distinta manera en les propietats mecàniques dels scaffolds porosos. S'ha estudiat la permeabilitat dels scaffolds, que ha resultat ser independent de la densitat d'entrecreuament de l'hidrogel dins dels seus porus. El model experimental de cartílag s'ha aplicat també a un scaffold macroporós acrílic. Els resultats mostren que l'aigua té un efecte distint en les propietats mecàniques dels scaffolds macroporosos i en els micro- macroporosos. El model de cartílag in vitro té valors del mòdul elàstic, mòdul agregat i permeabilitat que són del mateix ordre de magnitud que els del cartílag articular humà. El model permet predir el comportament mecànic in vivo de scaffolds porosos. S'ha dissenyat un dispositiu d'implant de scaffold per a experiments en animals basat en una patent del grup d'investigació, que ha segut implantat en dos assaigs in vivo diferents en ovelles. Els resultats mostren que la fixació i ancoratge a l'os subcondral té un gran paper en la reparació del teixit.Universitat Politècnica de ValènciaGallego Ferrer, GloriaGómez Ribelles, José LuísDepartamento de Termodinámica AplicadaCentro de Biomateriales e Ingeniería TisularEscuela Técnica Superior de Ingeniería IndustrialRepositorio Institucional de la Universitat Politècnica de València Riunet20152015-07-2920152015-07-14doctoral thesishttp://purl.org/coar/resource_type/c_db06AMhttp://purl.org/coar/version/c_ab4af688f83e57aainfo:eu-repo/semantics/doctoralThesisapplication/pdfapplication/mswordapplication/mswordhttps://riunet.upv.es/handle/10251/53912reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valénciainstname:Universitat Politècnica de València (UPV)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Reserva de todos los derechoshttp://rightsstatements.org/vocab/InC/1.0/info:eu-repo/semantics/openAccessoai:riunet.upv.es:10251/539122026-06-13T07:49:27Z
score 15,300724